Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "Hou, S." wg kryterium: Autor


Wyświetlanie 1-2 z 2
Tytuł:
Experimental investigation of a high temperature resistant and low friction fracturing fluid
Autorzy:
Xiao, B.
Zhang, S.
Zhang, J.
Hou, T.
Guo, T.
Powiązania:
https://bibliotekanauki.pl/articles/109339.pdf
Data publikacji:
2015
Wydawca:
Politechnika Wrocławska. Oficyna Wydawnicza Politechniki Wrocławskiej
Tematy:
high temperature fracturing fluid
resistance to shearing
hydroxypropyl guar
low friction
delayed crosslinking
Opis:
The performance of a hydraulic fracturing fluid (HFF) system directly determines the efficiency of stimulation. Since the targeted formations of most oil fields in China are characterized by large depth (~5000 m), high temperature (160 to 180 °C) and tight lithology, newer and suitable HFFs have to be developed. Based on a newly synthetized organo-boron/-zirconium cross-linking agent (Gh-g), a composite temperature stabilizer (WJ-6) and other optimized additives via indoor evaluation, this study introduced a novel HFF, which is thermally stable at high temperature (HT) up to 180 °C and exerted low friction pressures. The performance of HFF was evaluated in the laboratory. The experimental results showed that the HFF system performed well at HTs. It maintained a viscosity of 100 mPa•s or more after 90 min of shearing (170 s−1) at 180 °C. Furthermore, the system exhibited delayed cross-linking. It took 120 s for the cross-linking reaction to complete; therefore, the tube friction was reduced to a large extent. Another characteristic feature of the formulated HFF system was the low friction pressures, where the drag reduction percentage was in the range from 35% to 70%. Moreover, only minor damage was caused by the fluid to the formation core samples. The average core permeability damage was 19.6%. All these qualities ensure that this fluid system is in full compliance with the requirements of the fracturing treatment.
Źródło:
Physicochemical Problems of Mineral Processing; 2015, 51, 1; 37-47
1643-1049
2084-4735
Pojawia się w:
Physicochemical Problems of Mineral Processing
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Biomechanical evaluation of tendon connection with novel suture techniques
Autorzy:
Chen, Z.
Wang, J.
Wei, J.- S.
Hou, Z.-Y.
Li, M.
Chen, Q.-X
Powiązania:
https://bibliotekanauki.pl/articles/306902.pdf
Data publikacji:
2018
Wydawca:
Politechnika Wrocławska. Oficyna Wydawnicza Politechniki Wrocławskiej
Tematy:
ścięgno Achillesa
IFLL
biomechanika
internal fixation with limited loop
Achilles tendon
biomechanics
Opis:
Achilles tendon rupture is a severe injury with poor curative effect due to its anatomical characteristic and mechanical peculiarity. Internal fixation of limited loop (IFLL) with steel-wire has been applied on patients with tendon rupture to fix the broken ends before physical rehabilitation. The purpose of this study is to investigate the biomechanical property and radiological characteristic of such suture technique for the repairment of tendon rupture. Methods: Tendons of pigs’ hint feet were separated for the biomechanical study. Suture surgery was performed according to the protocol of IFLL. Biomechanical Testing Machine was adopted to conduct the biomechanical tensile load examination. The maximal load, elastic modulus and tendon stiffness of the stitched tendons with or without reinforcement were examined. Results: The maximum tensile load of the stitched tendons using IFLL reached 1/4 of the uninjured tendon’s maximum tensile load, indicating that such suture technique is capable of providing enough tension for the ruptured tendon. Surprisingly, tendons fixed with titanium wire showed the highest load tension, which was comparable to the undamaged tendon. Therefore, we found the biomechanical basis of using IFLL in effectively connecting the rupture ends of tendons. Conclusions: In conclusion, we provide biomechanical evidence for the use of IFLL in treatment of Achilles tendon rupture, by providing enough strength for the ankle function. Such suture technique could help the patients with better rehabilitation and reduced in-hospital stay after Achilles tendon injury.
Źródło:
Acta of Bioengineering and Biomechanics; 2018, 20, 1; 135-141
1509-409X
2450-6303
Pojawia się w:
Acta of Bioengineering and Biomechanics
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-2 z 2

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies