Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "archwires" wg kryterium: Wszystkie pola


Wyświetlanie 1-1 z 1
Tytuł:
Investigation of mechanical and physicochemical properties of clinically retrieved titanium-niobium orthodontic archwires
Autorzy:
Stoyanova-Ivanova, Angelina
Cherneva, Sabina
Petrunov, Vladimir
Petrova, Violeta
Ilievska, Ivana
Mikli, Valdek
Iankov, Roumen
Powiązania:
https://bibliotekanauki.pl/articles/306480.pdf
Data publikacji:
2020
Wydawca:
Politechnika Wrocławska. Oficyna Wydawnicza Politechniki Wrocławskiej
Tematy:
właściwości mechaniczne
morfologia
struktura
skład chemiczny
Ni-free orthodontic wires
titanium-niobium
mechanical properties
morphology
chemical composition
structure
Opis:
Most of the orthodontic archwires used in the clinical practice nowadays contain nickel (Ni), however, many patients, especially kids, are allergic to Ni. One possible Ni-free alternative is the Titanium-Niobium (Ti-Nb) archwire. Unfortunately, there is not enough information about its mechanical properties in the literature, especially after clinical usage. Therefore, the aim of this work was to investigate and compare the mechanical properties, chemical composition, structure and morphology of as received and used in clinical practice Ti-Nb orthodontic archwires. Materials and methods: We investigated and compared as received and clinically retrieved after 4 and 6 weeks respectively Ti-Nb archwires with dimensions 0.43 × 0.64 mm (0.017 in. × 0.025 in.). The following methods were used: instrumented indentation testing (nanoindentation), X-ray diffraction, scanning electron microscopy, energy-dispersive X-ray spectroscopy and X-ray photoelectron spectroscopy. Results: The nanoindentation investigations of as received and used Ti-Nb archwires revealed a decreasing in their indentation hardness with increased periods of use in the patient’s mouth. Moreover, an increasing of the concentration of Ti in the content of the TiNb alloy was associated with an increased period of use in the oral cavity. The SEM analysis showed changes in surface morphology with increasing the period of use of the archwires. Conclusions: The results showed that there are slight changes in the mechanical and physicochemical properties of the investigated wires after their use in the patient’s mouth. That is why we do not recommend them for recycling.
Źródło:
Acta of Bioengineering and Biomechanics; 2020, 22, 1; 31-39
1509-409X
2450-6303
Pojawia się w:
Acta of Bioengineering and Biomechanics
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-1 z 1

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies