Tytuł:
The influence of high- and low-heeled shoes on balance in young women
Autorzy:
Mika, A.
Oleksy, Ł.
Kielnar, R.
Świerczek, M.
Powiązania:
https://bibliotekanauki.pl/articles/306884.pdf
Data publikacji:
2016
Wydawca:
Politechnika Wrocławska. Oficyna Wydawnicza Politechniki Wrocławskiej
Tematy:
buty
balansowanie
platforma
propriocepcja
heeled shoes
balance
stabilometric platform
proprioception
Opis:
Purpose: To evaluate the influence of two different heel heights on static balance and on limits of stability during functional reach test, with both the eyes open and eyes closed, in young women (age 22–27) who did not wear heeled shoes habitually. Methods: Thirtyone young women (age 22–27) performed balance tests on a stabilometric platform without footwear and in shoes with 4 cm and 10 cm heels. The center of pressure (COP) deviations range and velocity in anteroposterior (AP) and mediolateral (ML) directions were assessed. The limits of stability were measured when the subject leaned the body in sagittal plane. Results: The ranges of COP deviations in AP and ML directions were already significantly higher in 4 cm heels in comparison to the barefoot condition. COP deviation velocity significantly raised with increasing heel height as well as when the eyes were closed. Conclusions: A more pronounced increase of COP deviation velocity than COP deviation range when measurement conditions become more difficult may indicate that young women anticipate postural corrections by stimulation of ankle proprioception when heeled shoes are worn. High-heeled shoes may lead to alterations in velocity feedback balance mechanism, which may increase the risk of musculoskeletal injuries. Observed in our study adverse effect of heeled footwear on balance may predispose women to falls and injuries. Permanent use of stiletto high heels should be avoided by women.
Źródło:
Acta of Bioengineering and Biomechanics; 2016, 18, 3; 97-103
1509-409X
2450-6303
Pojawia się w:
Acta of Bioengineering and Biomechanics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
The assessment of the applicability of shear wave elastography in modelling of the mechanical parameters of the liver
Autorzy:
Żmudzińska, M.
Inglot, M.
Zaleska-Dorobisz, U.
Jankowski, L.
Świątek-Najwer, E.
Powiązania:
https://bibliotekanauki.pl/articles/306904.pdf
Data publikacji:
2018
Wydawca:
Politechnika Wrocławska. Oficyna Wydawnicza Politechniki Wrocławskiej
Tematy:
elastografia
identacja
moduł Younga
shear wave elastography
indentation
Young’s modulus
porcine liver
Opis:
The development of haptic technology in laparoscopic simulations indicates a demand of constant upgrade of tactile feedback, which is currently considered to be unsatisfactory. Presumably, one of its causes may be insufficiently examined and described mechanical parameters of soft tissues in vivo, including liver tissue. The aim of the following work was the attempt at assessing the applicability of data from shear wave elastography in organ modelling by correlating the mechanical parameters of the liver obtained by this noninvasive method, with the mechanical parameters obtained by indentation. Methods: Each one out of 12 porcine livers, was subjected to elastography and subsequently to the indentation test. The mean Young’s modulus for each liver lobe was obtained using elastography, while in indentation Young’s moduli in three different strain ranges and maximum load were calculated. Results: Differences between mechanical parameters of lobes were not found but the parameters were calculated for different methods and strain ranges. Conclusions: The limitations of both methods prevent the unambiguous assessment of the applicability of elastography in liver modelling for laparoscopic simulations, at the presented stage of research. Nevertheless, the presented study provides a valuable introduction to the development of a methodology for testing the mechanical parameters of liver tissue.
Źródło:
Acta of Bioengineering and Biomechanics; 2018, 20, 4; 59-64
1509-409X
2450-6303
Pojawia się w:
Acta of Bioengineering and Biomechanics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Reference values of spatiotemporal parameters, joint angles, ground reaction forces, and plantar pressure distribution during normal gait in young women
Autorzy:
Fryzowicz, A.
Murawa, M.
Kabaciński, J.
Rzepnicka, A.
Dworak, L. B.
Powiązania:
https://bibliotekanauki.pl/articles/307416.pdf
Data publikacji:
2018
Wydawca:
Politechnika Wrocławska. Oficyna Wydawnicza Politechniki Wrocławskiej
Tematy:
kobieta
kinematyka
biomechanika chodu
pedobarografia
women
kinematics
ground reaction forces
gait biomechanics
pedobarography
reference data
Opis:
The aim of this study was to establish the reference values of spatiotemporal parameters, joint angles, ground reaction forces and plantar pressure distribution collected simultaneously on the same measurement path during normal gait in a homogenous group of young, healthy women. Methods: The studied group consisted of 28 healthy women aged 21 years on average. The motion capture system BTS Smart-D, 2 AMTI force platforms and Footscan pedobarographic platform were used in this research. The 14-metre measurement path and the 6-metre distance that examined women had to walk through before entering the measurement area ensured that a natural gait pattern was recorded. Statistical analysis was performed to evaluate differences between right and left lower extremities. Results: The applied method enabled collecting several parameters regarding normal female gait biomechanics such as: spatiotemporal parameters, angle-time characteristics as well as range of motion of pelvis, hip, knee and ankle joints in gait cycle, force-time characteristics and peaks of ground reaction force components in stance phase, peak pressure and time of loading of defined foot regions in stance phase. Conclusions: The results may be used by clinicians, physiotherapists or researchers as a reference in diagnosing gait disorders or evaluating patient’s walking pattern. In recent literature there are some disparities in gait parameters reference values even regarding similar research groups. These differences may arise from distinct method, slower or faster gait, other laboratory environment etc. This should be considered and more than one source of normative values should be checked when searching for reference data.
Źródło:
Acta of Bioengineering and Biomechanics; 2018, 20, 1; 49-57
1509-409X
2450-6303
Pojawia się w:
Acta of Bioengineering and Biomechanics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
The differences between overground and treadmill walking in nonlinear, entropy-based and frequency variables derived from accelerometers in young and older women : preliminary report
Autorzy:
Bizovska, L.
Svoboda, Z.
Kubonova, E.
Vuillerme, N.
Hirjakova, Z.
Janura, M.
Powiązania:
https://bibliotekanauki.pl/articles/307504.pdf
Data publikacji:
2018
Wydawca:
Politechnika Wrocławska. Oficyna Wydawnicza Politechniki Wrocławskiej
Tematy:
starzenie
chód
stabilność
stateczność dynamiczna
ageing
gait
stability
variability
local dynamic stability
Opis:
The aim of this study was to compare gait stability and variability between walking conditions and age groups. Methods: Twenty-six healthy younger and older females participated. Trunk acceleration in the vertical (V), medial-lateral (ML) and anteriorposterior (AP) directions during 5 minutes walking overground and 3 minutes walking on the treadmill at self-selected speed were recorded. Root mean square and standard deviations of acceleration, stride time and its variability, Lyapunov exponents (LE), multiscale entropy (MSE) and harmonic ratios (HR) were computed. Results: Both age groups showed significantly higher stride time variability and short-term LE in all directions during overground walking. For the older group, overground walking showed higher V and AP standard deviation. Significantly lower values for overground walking were observed for long-term LE (V and ML for the younger group, ML for the older group), HR (ML for the older group) and MSE (V for the older group). Significant age-related differences were found for V long-term LE for overground walking. Conclusions: The present findings suggest that both linear and advanced computational techniques for gait stability and variability assessment in older adults are sensitive to walking conditions.
Źródło:
Acta of Bioengineering and Biomechanics; 2018, 20, 1; 93-100
1509-409X
2450-6303
Pojawia się w:
Acta of Bioengineering and Biomechanics
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-4 z 4

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies