Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "Costa, A." wg kryterium: Wszystkie pola


Wyświetlanie 1-5 z 5
Tytuł:
Relationship between performance, dry-land power and kinematics in master swimmers
Autorzy:
Espada, M. C.
Costa, M. J.
Costa, A. M.
Silva, A. J.
Barbosa, T. M.
Pereira, A. F.
Powiązania:
https://bibliotekanauki.pl/articles/307228.pdf
Data publikacji:
2016
Wydawca:
Politechnika Wrocławska. Oficyna Wydawnicza Politechniki Wrocławskiej
Tematy:
pływanie
kinematyka
energia
master swimmers
kinematic
dry-land power
performance
Opis:
The purpose of the study was to analyze the relationships between sprint swimming performance, dry-land power, and kinematics in master swimmers. Twenty-two male master swimmers were separated in two groups based on their chronological age: (i) 30–39 years and; (ii) 40–49 years. Maximum dry-land power was determined through counter movement jump and 3 kg medicine ball throwing (Hmax and Tmax, respectively). Kinematic determinants of performance were measured during a maximal bout of 15, 25 and 50 m front crawl (T15, T25, T50). Stroke frequency (SF), stroke length (SL) and stroke index (SI) were calculated as kinematical aspects of the stroke. In the 30-39 group, SI25 was correlated to T25 (r = –0.76, p < 0.01, η2 = 0.96), the same was observed between SI50 and T50 (r = –0.83, p < 0.01, η2 = 0.96). Only SI50 was significantly correlated to T50 (r = –0.86, p < 0.01, η2 = 0.97) in the 40–49 years age cohort. In dryland power variables, Hmax and Tmax were only correlated in the younger master swimmers group (r = –0.87, p < 0.01, η2 = 0.97). There were no significant differences (p < 0.05) between younger (30–39 years) and older (40–49 years) swimmers groups in dry-land tests (Hmax 28.5 ± 5.9 vs. 26.5 ± 3.9 cm and Tmax 4.2 ± 1.0 vs. 4.2 ± 1.1 m). Our results suggest that swimming performance in younger master swimmers (30–39 years) seem more dependent on kinematic swimming variables than on strength parameters, which were most related to swimming performance in the older master swimmers (40–49 years).
Źródło:
Acta of Bioengineering and Biomechanics; 2016, 18, 2; 145-151
1509-409X
2450-6303
Pojawia się w:
Acta of Bioengineering and Biomechanics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
A 3D trabecular bone homogenization technique
Autorzy:
Marques, Marco Costa
Belinha, J.
Oliveira, A. F.
Manzanares Cespedes, M.C.
Natal Jorge, R.M.
Powiązania:
https://bibliotekanauki.pl/articles/27324130.pdf
Data publikacji:
2020
Wydawca:
Politechnika Wrocławska. Oficyna Wydawnicza Politechniki Wrocławskiej
Tematy:
fabric tensor
homogenization technique
multiscale
bone
tensor tkaniny
technika homogenizacji
wieloskalowe
kość
Opis:
Purpose: Bone is a hierarchical material that can be characterized from the microscale to macroscale. Multiscale models make it possible to study bone remodeling, inducing bone adaptation by using information of bone multiple scales. This work proposes a computationally efficient homogenization methodology useful for multiscale analysis. This technique is capable to define the homogenized microscale mechanical properties of the trabecular bone highly heterogeneous medium. Methods: In this work, a morphology-based fabric tensor and a set of anisotropic phenomenological laws for bone tissue was used, in order to define the bone micro-scale mechanical properties. To validate the developed methodology, several examples were performed in order to analyze its numerical behavior. Thus, trabecular bone and fabricated benchmarks patches (representing special cases of trabecular bone morphologies) were analyzed under compression. Results: The results show that the developed technique is robust and capable to provide a consistent material homogenization, indicating that the homogeneous models were capable to accurately reproduce the micro-scale patch mechanical behavior. Conclusions: The developed method has shown to be robust, computationally less demanding and enabling the authors to obtain close results when comparing the heterogeneous models with equivalent homogenized models. Therefore, it is capable to accurately predict the micro-scale patch mechanical behavior in a fraction of the time required by classic homogenization techniques.
Źródło:
Acta of Bioengineering and Biomechanics; 2020, 22, 3; 139--152
1509-409X
2450-6303
Pojawia się w:
Acta of Bioengineering and Biomechanics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Assessment of isometric strength of the shoulder rotators in swimmers using a handheld dynamometer : a reliability study
Autorzy:
Coinceicao, A.
Parraca, J.
Marinho, D.
Costa, M.
Louro, H.
Silva, A.
Batalha, N.
Powiązania:
https://bibliotekanauki.pl/articles/306193.pdf
Data publikacji:
2018
Wydawca:
Politechnika Wrocławska. Oficyna Wydawnicza Politechniki Wrocławskiej
Tematy:
siłomierz
pływanie
młodzi pływacy
handheld dynamometer
prone position
young swimmers
swimming
Opis:
The purpose of this study was to determine the reliability of shoulder isometric strength assessment using the microfet 2™ dynamometer in adolescent swimmers. Methods: Twenty-nine participants (16.2 ± 1.2 years old; 59.05 ± 6.98 kg of body mass) were tested using the microfet 2™ dynamometer. Swimmers performed an isometric strength test (IST) in two distinct occasions with 7 days apart in order to calculate the reliability. All participants were asked to perform a maximal isometric contraction from the external and internal shoulder rotators in a prone body position. Results: The external and internal shoulder rotators showed an excellent intraclass correlation coefficients for both shoulders, with more than 0.90 and a low percentage of method error variation. The external/internal ratios reliability was good in dominant (ICC 0.80) and non-dominant (ICC 0.81) shoulders. The reliability using Bland–Altman method showed that systematic errors (mean difference between test-retest) were nearly zero and the 95% limits of agreement narrow, indicating a good reliability. Conclusions: It can be concluded that microfet 2™ is a reliable apparatus for measuring the strength of the external and internal rotation of the shoulder in swimmers. Its light weight and easy portable characteristics can help swimming coaches monitoring specific dry-land strength training programs for their swimmers.
Źródło:
Acta of Bioengineering and Biomechanics; 2018, 20, 4; 113-119
1509-409X
2450-6303
Pojawia się w:
Acta of Bioengineering and Biomechanics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Can concurrent teaching promote equal biomechanical adaptations at front crawl and backstroke swimming?
Autorzy:
Costa, M. J.
Barbosa, T. M.
Morais, J. E.
Miranda, S.
Marinho, D. A.
Powiązania:
https://bibliotekanauki.pl/articles/307054.pdf
Data publikacji:
2017
Wydawca:
Politechnika Wrocławska. Oficyna Wydawnicza Politechniki Wrocławskiej
Tematy:
ekspertyza
kinematyka ruchu
pływak
expertise
kinematics
swimmer
Opis:
Purpose: The biomechanical adaptations in front crawl and backstroke swimming, as influenced by the implementation of a concurrent teaching programme were analysed. Methods: Sixteen participants (19.75 ± 1.13 years) underwent a 30 weeks intervention characterized by an increasing complexity to accomplish motor skills in the following order: (i) lower limbs propulsion; (ii) lower limbs propulsion synchronized with breathing cycle; (iii) lower limbs propulsion synchronized with one upper limb action; (iv) lower limbs propulsion synchronized with both breathing cycle and one upper limb action; (v) full swimming stroke; (vi) motor trajectory of the arms stroke. Performance and biomechanics were measured at front crawl and backstroke during three time points throughout the programme. Results: There were improvements in performance over time at front crawl (21.49 s to 19.99 s, p < 0.01) and backstroke (27.15 s to 24.60 s, p = 0.01). Significant improvements were found for velocity at front crawl (1.13 m/s to 1.22 m/s, p < 0.01) and backstroke (0.92 m/s to 1.00 m/s, p < 0.01). Stroke frequency increased at backstroke (0.64 to 0.73 Hz, p = 0.01), while the intra-cyclic variation of the velocity decreased at front crawl (0.13 to 0.12%, p = 0.02). There was also a moderate-high inter-subject variability in response to the programme. Conclusions: These findings prove that a programme of 30 weeks teaching concurrently front crawl and backstroke is effective to promote similar biomechanical adaptations in low-tier swimmers. However, each subject shows an individual response to better adapt the biomechanical actions and to reach a higher level of expertise.
Źródło:
Acta of Bioengineering and Biomechanics; 2017, 19, 1; 81-88
1509-409X
2450-6303
Pojawia się w:
Acta of Bioengineering and Biomechanics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Tracking young talented swimmers : follow-up of performance and its biomechanical determinant factors
Autorzy:
Morais, J. E.
Saavedra, J. M.
Costa, M. J.
Silva, A. J.
Marinho, D. A.
Barbosa, T. M.
Powiązania:
https://bibliotekanauki.pl/articles/951824.pdf
Data publikacji:
2013
Wydawca:
Politechnika Wrocławska. Oficyna Wydawnicza Politechniki Wrocławskiej
Tematy:
prepubescent swimmers
longitudinal assessment
kinematics
drag force
anthropometrics
efficiency
kinematyka
efektywność
pływak
biomechanika
Opis:
The aim of the study was to follow-up the stability of young talented swimmers’ performance and its biomechanical determinant factors (i.e., anthropometrics, kinematics, hydrodynamics and efficiency) during a competitive season. Thirty three (15 boys and 18 girls) young swimmers (overall: 11.81 ± 0.75 years old and Tanner stages 1–2 by self-evaluation) were evaluated. Performance, anthropometrics, hydrodynamics, kinematics and efficiency variables were assessed at three moments during a competitive season. Performance had a significant improvement (with minimum effect size) and a moderate-very high stability throughout the season. In the anthropometrics domain all variables increased significantly (ranging from without to minimum effect size) between moments and had a moderate-very high stability. Hydrodynamics presented no variations between all moments and had a low-very high stability throughout the season. In the kinematics domain, there were no variations between moment one and three, except for an increase in stroke frequency (without size effect). Speed fluctuation remained constant, with no significant variations. All kinematic variables had a low-very high stability. Efficiency variables did not present variations between moment one and three and had a low-moderate stability. Overall, young swimmers showed a minimum improvement in performance and in anthropometric factors; and a moderate stability of performance and its determinant factors (i.e., anthropometrics, hydrodynamics, kinematics and efficiency) during the competitive season.
Źródło:
Acta of Bioengineering and Biomechanics; 2013, 15, 3; 129-138
1509-409X
2450-6303
Pojawia się w:
Acta of Bioengineering and Biomechanics
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-5 z 5

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies