Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "sewage sludge treatment" wg kryterium: Temat


Wyświetlanie 1-7 z 7
Tytuł:
Influence of Mesophilic Digestion of Dairy Sewage Sludge on Content of Chosen Heavy Metals and their Fractions
Wpływ procesu fermentacji mezofilowej na zawartość wybranych metali i ich frakcji w osadzie z oczyszczalni ścieków mleczarskich
Autorzy:
Dąbrowski, Wojciech
Ignatowicz, Katarzyna
Powiązania:
https://bibliotekanauki.pl/articles/1811972.pdf
Data publikacji:
2019
Wydawca:
Politechnika Koszalińska. Wydawnictwo Uczelniane
Tematy:
heavy metals
fraction
sewage sludge treatment
metale ciężkie
frakcje metali
przeróbka osadów
Opis:
In this work, there were shown the research results concerning anaerobic digestion in the mesophilic condition. There was done the assessment of content of chosen heavy metals and their fractions in dairy sewage sludge before and after digestion process. The research was conducted with the use of laboratory installation on the base of mixture of excessive and floatation sludge. The process parameters were adopted from the modernization project of dairy sewage treatment plant of Mlekovita cooperative in Wysokie Mazowieckie. The results showed that in case of agricultural use of sludge, the total amount of heavy metals in sludge after anaerobic digestion was sharply lower that the values demanded in regulation concerning municipal sewage sludge. The process of sludge digestion caused the increase of metals content in dry matter of sludge. Metals speciation was determined with the use of scheme in accordance with methodology worked by BRC, which meant indicating four fractions. In case of lead, copper and zinc, the researches of anaerobic digestion process of dairy sludge showed the little increase of immobile fraction. The decrease of metals fraction was observed in case of cadmium, nickel and the clearest – chromium.
W pracy zaprezentowano wyniki badań dotyczących procesu stabilizacji beztlenowej w warunkach mezofilowych. Dokonano oceny zawartości wybranych metali ciężkich i ich frakcji w osadzie mleczarskim przed i po procesie stabilizacji. Badania prowadzono z zastosowaniem układu laboratoryjnego w oparciu o mieszaninę osadu nadmiernego i flotacyjnego. Parametry procesu zostały adoptowane z projektu modernizacji oczyszczalni ścieków mleczarskich firmy Mlekovita w Wysokiem Mazowieckiem. Stwierdzono, iż ogólna ilość metali ciężkich w osadzie po procesie stabilizacji beztlenowej jest znacznie niższa niż wartości wymagane w rozporządzeniu w sprawie komunalnych osadów ściekowych w przypadku rolniczego wykorzystania osadu. Proces stabilizacji osadu spowodował wzrost zawartości metali w suchej masie osadu. Specjację metali określono za pomocą schematu zaproponowanego przez zgodnie z metodyką opracowaną przez BCR wyodrębniając cztery frakcje. Przeprowadzone badania procesu stabilizacji beztlenowej osadów mleczarskich wykazały niewielki wzrost frakcji niemobilnej w przypadku ołowiu, miedzi i cynku. Zmniejszenie tej frakcji metali zaobserwowano w przypadku kadmu i niklu, i najwyraźniej w przypadku chromu.
Źródło:
Rocznik Ochrona Środowiska; 2019, Tom 21, cz. 2; 962-973
1506-218X
Pojawia się w:
Rocznik Ochrona Środowiska
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Assessment of Treatment Effect of Heavy Metal Pollution from Sewage Sludge in Wastewater Treatment Plant Discharge in China’s Nanjing MV Industrial Park
Autorzy:
Xu, Lingjuan
Sun, Fengqi
Han, Xiuyan
Powiązania:
https://bibliotekanauki.pl/articles/2174921.pdf
Data publikacji:
2022
Wydawca:
Politechnika Koszalińska. Wydawnictwo Uczelniane
Tematy:
assessment of treatment effect
heavy metal pollution
niche model
sewage sludge
wastewater treatment plant
Opis:
To explore methods for a comprehensive assessment of the treatment effect of heavy metal pollution in the sewage sludge from China’s industrial parks, we studied the wastewater treatment plant of the Nanjing MV Industrial Park as an example. Eight common heavy metals in sewage sludge – Zinc (Zn), Copper (Cu), Lead (Pb), Mercury (Hg), Chromium (Cr), Nickel (Ni), Arsenic (As), Cadmium (Cd) were studied. The treatment effect of these containments was comprehensively assessed using the absolute niche fitness model, the relative niche model and the spatial niche fitness model. All three models showed that Pb > Cu > Ni > Hg > Cd > Cr > Zn > As in the samples. However, they produced – different numerical values – the absolute niche suitability model < the spatial niche suitability model < and the relative niche suitability model. Therefore, we concluded that special attention should be paid to the carcinogenic risk of As and Cr heavy metals to the person exposed to the sewage sludge.
Źródło:
Rocznik Ochrona Środowiska; 2022, 24; 276--293
1506-218X
Pojawia się w:
Rocznik Ochrona Środowiska
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Characteristics of Sludge Node Operation at Wastewater Treatment Plant in Żory
Charakterystyka funkcjonowania węzła przeróbki osadów ściekowych na oczyszczalni ścieków w Żorach
Autorzy:
Zdebik, Dariusz
Zawadzki, Piotr
Pieczonka, Michał
Powiązania:
https://bibliotekanauki.pl/articles/1812051.pdf
Data publikacji:
2019
Wydawca:
Politechnika Koszalińska. Wydawnictwo Uczelniane
Tematy:
wastewater treatment plant
activated sludge
sewage sludges
wastewater quality
leachate
sewage sludge management
oczyszczalnia ścieków
osad czynny
osady ściekowe
jakość ścieków
odciek
gospodarka osadowa
Opis:
The purpose of this work was to analyze work of the sludge part of the wastewater treatment plant in Żory. During the analysed period (years 2015-2017) the wastewater treatment plant in Żory worked in conditions typical for the municipal facilities. The characterization of the sludge generated in the wastewater treatment process has also shown that the sludge properties are typical for the municipal wastewater treatment plants. Based on the data provided by the PWiK Sp. z o. o. in Żory. the characteristics of the technological process were made. This characteristics in a detailed way includes the sludge part of the treatment plant. The analysis of the functioning of the sludge part was performed and the influence of the pollutants load in leachates on the effectiveness of work in the main technological line was characterized. Studies on the functioning of the sludge part showed discrepancies between the design status of the wastewater treatment plant and the real state. This is due to the increasing amount of the wastewater flowing into the treatment plant and the associated increase in the amount of the occurring sludge. The belt press and the digested sludge tank are particularly loaded. The belt press works for about 11.9 h/d with assumed 4.1 h/d. In turn. the residence time of the sludge in the digested sludge tank is about 3 times shorter than assumed. Despite the observed. increasing concentrations of pollutants and the amount of treated wastewater. the plant meets the legal requirements regarding the quality of the wastewater discharged to the receiver by the water-legal permit and the Regulation of the Minister of the Environment. Based on the results of laboratory tests of the wastewater and leachates generated in the process of dewatering on the filter presses. their impact on the efficiency of treatment in the main technological line was characterized. The amount of leachates in relation to the amount of the wastewater flowing into the treatment plant was 1.8%. The leachates had high content of ammonium nitrogen. total phosphorus and total suspended solids. The average concentrations of these parameters were: SNNH4 = 592.6 mg/dm3, SNog = 664.8 mg/dm3, SPog = 197.7 mg/dm3 and SZog = 1100.9 mg/dm3. The average values of BOD5 and COD indices were SBOD5 = 66.4 mg/dm3, and SCOD = 386.9 mg/dm3. The leachates coming from the filter presses carried a significant load of total phosphorus. which constituted on average 27.3% of the total load flowing into the treatment plant. as well as the total suspension and total nitrogen. which maximum load constituted 7.3% (Zog) and 11.8% (Nog) of the total load flowing into the treatment plant. The ratio of COD/BOD5 indices of pollutants of the leachates from the presses was 5.83. which indicated the introduction of hardly biodegradable compounds into the main technological line. In order to increase the efficiency of nitrogen removal in the main technological line it was proposed the implementation of deammonification process of the leachates from the sludge dewatering. aiming to reduce the ammonium nitrogen load. introduced to the biological part of the treatment plant.
Celem niniejszej pracy była analiza pracy części osadowej oczyszczalni ścieków w Żorach. Oczyszczalnia ścieków w Żorach w analizowanym okresie (lata 2015-2017) pracowała w warunkach typowych dla miejskich obiektów komunalnych. Również charakterystyka osadów powstających w procesie oczyszczania ścieków wykazała. że właściwości osadów są typowe dla miejskich oczyszczalni ścieków. Na podstawie danych udostępnionych przez PWiK Sp. z o.o. w Żorach. dokonano charakterystyki procesu technologicznego. Charakterystyka w sposób szczegółowy uwzględnienia część osadową oczyszczalni. Dokonano analizy funkcjonowania części osadowej oraz scharakteryzowano wpływ ładunku zanieczyszczeń w odciekach na skuteczność pracy w głównym ciągu technologicznym. Badania dotyczące funkcjonowania części osadowej wykazały rozbieżności między stanem projektowym oczyszczalni ścieków. a stanem rzeczywistym. Wynika to z faktu zwiększającej się ilości ścieków dopływających na oczyszczalnię oraz związanym z tym przyrostem ilości powstających osadów. Szczególnie obciążone w układzie są prasa taśmowa oraz zbiornik osadu przefermentowanego. Prasa taśmowa pracuje przez około 11.9 h/d przy zakładanych 4.1 h/d. Z kolei czas przebywania osadów w zbiorniku osadu przefermentowanego jest około 3 razy krótszy od zakładanego. Pomimo obserwowanych. zwiększających się stężeń zanieczyszczeń oraz ilości oczyszczanych ścieków. oczyszczalnia spełnia wymagania prawne dotyczące jakości ścieków odprowadzanych do odbiornika nadane przez pozwolenie wodnoprawne oraz Rozporządzenie Ministra Środowiska. W opraciu o wyniki badań laboratoryjnych ścieków i odcieków powstałych w procesie odwadniania na prasach filtracyjnych.scharakteryzowano ich wpływ na skuteczność oczyszczania w głównym ciągu technologicznym. Ilość odcieków w stosunku do ilości ścieków dopływających do oczyszczalni wynosiła 1.8%. W odciekach stwierdzono wysoką zawartość azotu amonowego. fosforu ogólnego oraz zawiesiny ogólnej. Średnie stężenia wymienionych parametrów wynosiły: SNNH4 = 592.6 mg/dm3, SNog = 664.8 mg/dm3, SPog = 197.7 mg/dm3 oraz SZog = 1100.9 mg/dm3. Średnie wartości wskaźników BOD5 oraz COD wynosiły SBOD5 = 66.4 mg/dm3 i SCOD = 386.9 mg/dm3. Odcieki z pras filtracyjnych niosły znaczny ładunek fosforu ogólnego. który stanowił średnio 27.3% całkowitego ładunku dopływającego do oczyszczalni oraz zawiesiny ogólnej i azotu ogólnego. których ładunek maksymalny stanowił 7.3% (Zog) oraz 11.8% (Nog) całkowitego ładunku dopływającego do oczyszczalni. Stosunek wskaźników zanieczyszczeń COD/BOD5 odcieków z pras wynosił 5.83. co wskazywało na wprowadzanie do głównego ciągu technologiczne związków trudno rozkładalnych. W celu zwiększenia efektywności usuwania azotu w głównym ciągu technologicznym zaproponowano implementację procesu deamonifikacji odcieków z odwadniania osadów w celu redukcji ładunku azotu amonowego wprowadzanego do części biologicznej oczyszczalni.
Źródło:
Rocznik Ochrona Środowiska; 2019, Tom 21, cz. 2; 1445-1460
1506-218X
Pojawia się w:
Rocznik Ochrona Środowiska
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Usuwanie fosforanów z wykorzystaniem osadów potechnologicznych pochodzących ze stacji uzdatniania wody
Removal of Phosphates with Post-technological Sludge from Water Treatment Plant
Autorzy:
Totczyk, G.
Klugiewicz, I.
Pasela, R.
Górski, Ł.
Powiązania:
https://bibliotekanauki.pl/articles/1818613.pdf
Data publikacji:
2015
Wydawca:
Politechnika Koszalińska. Wydawnictwo Uczelniane
Tematy:
osady z uzdatniania wody
osady pokoagulacyjne zawierające glin
defosfatacja
TZB
oczyszczalnia ścieków
water processing sludge
alumina water processing sludge
dephosphatation
RBC
sewage treatment plant
Opis:
With the treatment of water, especially surface waters, there is produced a high amount of sewage and sludge. They make up a serious ecology problem that due to a high volume and the content of sludge of iron or aluminium oxide-hydroxide or, pollution which occur in the intaken water (mineral and organic substances, algae, protozoa and bacteria) as well as the chemicals added. The environmental protection requires limiting materials as well as it makes you search for effective waste management problem-solving methods. The waste generated at present during water treatment most often undergo dehydration and drying and then they are deposited at the landfill site. The currently binding environmental protection law makes you look for the possibilities of the use of sludge as recycled materials, e.g. in brick factories, cement factories or with sewage treatment. Sludge containing aluminium or iron can be used e.g. in the process of municipal sewage treatment. The application of sludge containing aluminium for dephosphatation has the advantage of protecting the system from secondary release of precipitated phosphates in the environment deprived of dissolved oxygen. The possibilities of sludge application to remove phosphates differ, depend not only on the sludge characteristics but also on the sewage treatment process. The article demonstrates the results of research into using sludge derived from water treatment station in Lubicz to remove phosphates from sewage. At present the sludge after sedimentation and mechanical dehydration with the filtration press finally reaches the municipal landfill site. The sludge, applied for research, concentrated in settling vessels, is a mixture of post-coagulation sludge and washings from anthracite-sand and carbon filters. Its hydration accounting for 98,7% shows a high colour, above 80 mg Pt/dm3, it contains about 2,6 g/dm3 of aluminium as well as organic compounds expressed with BOD5 value equal 170 mg O2/dm3. The sludge shows a high COD of 3990 mg O2/dm3, and organic substance – for 31,6% of dry weight. The study of effectiveness of the removal of phosphates was made with the vessel test method. The sludge was dispensed at a changing volume from 0,5 to 100 cm3 per 1 dm3 of prepared water and then sewage. Both in water and in sewage there was recorded a 90% removal of phosphates by applying 80 cm3 of sludge per 1 dm3 of the sample. Additionally there was investigated the effect of dispensed sludge on the effectiveness of sewage treatment with the model of the treatment plant with rotating biological contactors. Applying the rate of 40 cm3 of sludge per 1 dm3 produced 96,0% elimination of COD, 97,7% removal of organic compounds characterised with the values of COD and BOD5 as well as 100% removal of phosphates. Finally it was found that it is possible to use the sludge to remove phosphates from sludge. During dephosphatation there was reported no use-up of the natural alkalinity of sewage. Sludge dispensing did not result in a decrease in the effectiveness of sewage treatment with the method of rotating biological contactors. The research is preliminary in nature and it needs to be continued.
Źródło:
Rocznik Ochrona Środowiska; 2015, Tom 17, cz. 2; 1660-1673
1506-218X
Pojawia się w:
Rocznik Ochrona Środowiska
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Podczyszczanie ścieków organicznych metodą koagulacji siarczanem glinu
Pre-treatment of Organic Wastewater by Coagulation with Aluminium Sulphate
Autorzy:
Kościelnik, B.
Kowalska, A.
Powiązania:
https://bibliotekanauki.pl/articles/1813867.pdf
Data publikacji:
2017
Wydawca:
Politechnika Koszalińska. Wydawnictwo Uczelniane
Tematy:
podczyszczanie ścieków organicznych
kleje organiczne
przetwórstwo drewna
oczyszczanie ścieków
koagulacja
siarczan glinu
organic sewage sludge
organic adhesives
wood processing
sewage treatment
coagulation
aluminum sulphate
Opis:
W pracy przedstawiono wyniki badań laboratoryjnych jednego węzła układu technologicznego podczyszczania ścieków przemysłowych, których dominującym składnikiem były resztki kleju oraz utwardzacza. Badania dotyczyły koagulacji siarczanem glinu Al2(SO4)3 i sedymentacji grawitacyjnej. Ponadto, oceniono wpływ dawki koagulanta, czasu sedymentacji oraz stężenia początkowego zanieczyszczeń na efektywność procesu. Zastosowanie koagulacji siarczanem glinu umożliwiło zmniejszenie o około 80% stężenia substancji organicznych trudno rozkładalnych wyrażonych jako ChZT oraz o 75% stężenia węgla organicznego. Jako optymalne warunki procesu przyjęto dawkę Al2(SO4)3 wynoszącą 0,6 g/dm3 oraz czas sedymentacji ts 2 godziny. Wartości wskaźników zanieczyszczeń w wodzie nadosadowej po koagulacji zależały ściśle od stężenia początkowego w ściekach, przy czym zależność ta (spadek) była liniowa. Zaproponowano, aby ścieki po koagulacji i sedymentacji grawitacyjnej były doczyszczane w kolejnych węzłach, tj. w procesie filtracji grawitacyjnej oraz sorpcji. Na podstawie uzyskanych wyników badań wyznaczono, stosując metodę punktu centralnego, równania analityczno-empiryczne opisujące wpływ poszczególnych parametrów niezależnych na wartości parametrów wynikowych.
This paper presents results of laboratory investigations on one node of proposed technological setup for pre-treatment of industrial wastewater, which contain mainly residual glue and hardener. The investigations concern coagulation process with application of Al2(SO4)3 and sedimentation process. Authors estimated influence of coagulant dose, sedimentation time and initial concentration of contaminants on process effectiveness. Applied process of coagulation with Al2(SO4)3 reduces concentration of organic substances hardy digestible (COD) almost 80% and 75% of organic carbon . The investigations allowed to determine optimal values of process parameters: Al2(SO4)3 dose – 0.6 g/dm3, sedimentation time – 2 hours. The values of contamination parameters in wastewater after sedimentation depended strictly on their concentration before process, and this dependence (decrease) was linear. Pre-treatment of wastewater containing glue using coagulation Al2(SO4)3 allowed to decrease concentrations of all contamination parameters, which were investigated in this work. However, when compared with requirements for wastewater inflowing to sewage system, wastewater after coagulation should undergo next processes proposed in technological setup, including filtration ad sorption. On the basis of investigation results, analytical and empirical equations, which describe influence of individual independent parameters on resulting parameters, were determined using method of central point.
Źródło:
Rocznik Ochrona Środowiska; 2017, Tom 19; 557-571
1506-218X
Pojawia się w:
Rocznik Ochrona Środowiska
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Ocena składu fizyczno-chemicznego osadów ściekowych pochodzących z komunalnej oczyszczalni ścieków
Evaluation of the Physico-chemical Composition of Sludge from Municipal Sewage Treatment Plant
Autorzy:
Milik, J.
Pasela, R.
Szymczak, M.
Chalamoński, M.
Powiązania:
https://bibliotekanauki.pl/articles/1818029.pdf
Data publikacji:
2016
Wydawca:
Politechnika Koszalińska. Wydawnictwo Uczelniane
Tematy:
osady ściekowe
skład chemiczny
metale ciężkie
substancja organiczna
oczyszczanie ścieków komunalnych
sewage sludge
chemical
heavy metals
organic material
waste waters treatment
Opis:
Municipal sewage sludge are a by-product of waste water treatment. The problems of sludge associated with the development of sludge require urgent solutions. Municipal sewage sludge may be used in agriculture in two forms: processed and unprocessed if they are stabilized and comply with acceptable levels of heavy metals and sanitation indicators and include the relevant product quantities of organic compounds and fertilizing nitrogen, phosphorus and potassium. Composition and quantity of sludge produced in the wastewater treatment process is different and depends on several parameters such as quality of waste water and processes for their purification. The presents shows an assessment of the physical and chemical sludge from sewage treatment plants selected and the results of research and analysis for the sludge collected from said object. Analysis of the results was carried out for possibilities to use sewage sludge for agricultural purposes. Sewage sludge derived from a sewage treatment plant mechanical-biological stabilization of sludge anaerobic digestion with a capacity of 26,400 m3. per day. The sediment samples were collected in the period from January to September 2015 year with a two-month interval. Attempts were subjected to microwave mineralization in a closed system in aqua regia. The heavy metal concentrations determined with a spectrophotometer Coupled Plasma emission ICP-OES Perkin-Elmer Optima 8000 detecting elements P, Ca, Mg, Pb, Cd, Hg, Ni, Zn, Cu, Cr. The collected sediment were determined: pH, dry weight of sediment, organic matter (marked as loss on ignition at 550 ° C), total nitrogen (Kjeldahl) and ammonium nitrogen. The results were compared with the limit values according to the law. It has been shown that the predominant heavy metals present in the sludge was copper and zinc, mercury was not detected. The value of organic matter sludge tested ranged from 49.36 to 63.15% of dry matter. The content of heavy metals in sediments was measured by reference to the existing provisions governing the use of natural sewage sludge. The contents of heavy metals were low and did not exceed the limit values in sewage sludge for their use in agriculture and land reclamation. The studied sediments were stable nature. The results indicate the good properties of the sludge, which can be used as organic fertilizer. It has been shown that the sludge produced in the study treatment did not exceed in any case permissible concentrations of heavy metals specified for sewage sludge used for agricultural purposes. The annual average content of heavy metals in the study period remained at a similar level. Understanding the composition of the physico-chemical sludge waste is the basis for the decision over their processing, use or disposal. The precipitate may be disposed by using thermal methods for combustion of solid comprising 90% of dry matter.
Źródło:
Rocznik Ochrona Środowiska; 2016, Tom 18, cz. 2; 579-590
1506-218X
Pojawia się w:
Rocznik Ochrona Środowiska
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Zrównoważone gospodarowanie ściekami na przykładzie obszarów wiejskich
Sustainable Sewage Management in Rural Areas
Autorzy:
Obarska-Pempkowiak, H.
Kołecka, K.
Gajewska, M.
Wojciechowska, E.
Ostojski, A.
Powiązania:
https://bibliotekanauki.pl/articles/1818174.pdf
Data publikacji:
2015
Wydawca:
Politechnika Koszalińska. Wydawnictwo Uczelniane
Tematy:
oczyszczanie ścieków
oczyszczalnie hydrofitowe
gospodarka wodno-ściekowa
sanitacja
zagospodarowanie osadów ściekowych
wastewater treatment
constructed wetlands
water and wastewater management
sanitation
sewage sludge management
Opis:
The Baltic Sea is highly susceptible to eutrophication. Among the nine countries located in the Baltic Sea catchment area Poland discharges the biggest load of nitrogen and phosphorus. Although in recent years this load has been significantly reduced, however it is still too high. No sustainable municipal management results in the decreasing water quality of the Baltic Sea contributing to the sea eutrophication. The implementation of the National Programme for Development of Sewage caused a number of activities related to the construction and modernization of existing wastewater treatment plants. Although the number of wastewater treatment plants has been constantly increasing, still a number of households do not have the possibility to connect to the municipal wastewater treatment plant, mainly for economic reasons. Although in Poland there is 3157 municipal wastewater treatment plants (the most in Central and Eastern Europe), only 64% of the population is connected to them. It is estimated that 7.64 million people do not have the possibility of connection to municipal wastewater treatment plants. One of the solutions to wastewater management, especially in non-urbanized areas, are on-site wastewater treatment plants, for example treatment wetland systems. These technologies provide a sustainable solution of sewage and sludge management, since they can be used not only for treatment of wastewater, but also for dewatering and stabilization of produced sewage sludge. The article presents the results of research on local constructed wetlands for biological wastewater treatment (from 15 to 750 inhabitants) located in Darżlubie, Wieszyno, Wiklino, Sarbsk and Schodno as well as individual treatment wetlands representing 9 on-site wastewater treatment plants built in three different configurations in the municipality of Stężyca. There are also results of research from sludge treatment reed beds used for dewatering and stabilization of sewage sludge from municipal wastewater treatment plants located in Denmark (Helsinge, Rudkobing, Nakskov, Vallo) and in Poland (Gniewino). Based on studies related to the latest examples of wastewater and sewage sludge management using treatment wetlands it has been shown that this method is a good example of ecological engineering. Local treatment wetland systems can be used as the second stage of wastewater treatment up to 3500 residents. With proper operation of primary tanks, these systems are characterized by high treatment efficiency. Treatment wetland systems can work as on-site wastewater treatment plants. The highest efficiency of pollutant removal was observed in the hybrid systems. Another facilities, constructed as reed beds or basins, are applied to effective dewatering and stabilization of sewage sludge. These facilities offer a sustainable solution of sludge management in local conditions.
Źródło:
Rocznik Ochrona Środowiska; 2015, Tom 17, cz. 1; 585-602
1506-218X
Pojawia się w:
Rocznik Ochrona Środowiska
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-7 z 7

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies