Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "endotoxins" wg kryterium: Temat


Wyświetlanie 1-2 z 2
Tytuł:
Aerozole pochodzenia bakteryjnego w pomieszczeniach roboczych zakładu gospodarki odpadami
Aerosols of Bacterial Origin in Working Rooms of Waste Management Facility
Autorzy:
Cyprowski, M.
Stobnicka, A.
Górny, R.
Gołofit-Szymczak, M.
Ławniczek-Wałczyk, A.
Powiązania:
https://bibliotekanauki.pl/articles/1818046.pdf
Data publikacji:
2016
Wydawca:
Politechnika Koszalińska. Wydawnictwo Uczelniane
Tematy:
zakład gospodarki odpadami
bakterie
peptydoglikany
endotoksyny
rozkłady ziarnowe
waste management facility
airborne bacteria
peptidoglycans
endotoxins
size distribution
Opis:
The aim of the research was to identify aerosols of bacterial origin, including aerobic and anaerobic bacteria, peptidoglycans and endotoxins in working rooms of waste management facility, which included sorting and composting of municipal waste. Four sampling points were located in the plant: in the pre-sorting cab, in sorting hall at conveyor belts, in the composting bunkers hall, as well as in the front of entrance gate, as a sample of external background. Air samples for the presence of bacteria were collected using a 6-stage Andersen impactor, wherein two types of microbial media were loaded: TSA agar with defibrinated sheep blood for aerobic bacteria and Schaedler's agar for anaerobic bacteria. Air samples for the presence of endotoxins and peptidoglycans were carried out using 8-stage cascade impactor, wherein the glass fiber filters were provided. Biochemical API tests were used for a detailed identification of bacteria. Determination of peptidoglycans was carried out using the SLP test (Silkworm Larvae Plasma) and endotoxin - LAL assay (Limulus Amebocyte Lysate). The results of the quantitative analysis of bioaerosols at the three tested working rooms showed the following geometric mean (GM) concentrations: aerobic bacteria – 4348 cfu/m3 (geometric standard deviation, GSD = 1.14); anaerobic bacteria – 19914 cfu/m3 (GSD = 3.65); endotoxins – 173.6 ng/m3. (GSD = 2.39); peptidoglycans – 1446.6 ng/m3 (GSD = 1.21). Comparative analysis revealed statistically significant differences (p < 0.01) between the concentrations of aerobic bacteria in the working rooms and the external background – 551 cfu/m3. Anaerobic bacteria were the dominant group and accounted for 82% of all identified microorganisms. A total of 22 species of bacteria, belonging to 13 genera was identified in waste management facility. The greatest taxonomic diversity was observed in the sorting area (21 species), composting – 15, while in the background samples – 13 species. Among the identified species, six (Actinomyces israelii, A. meyeri, A. naeslundii, Clostridium perfrin-gens, Proteus vulgaris, and Streptomyces spp. can be treated as potentially harmful to waste workers, as they were classified into the second risk group by the ordinance of Minister of Health from 2005. Analysis of size distributions of bacteria showed that they occurred mostly in the form of single cells with an aerodynamic diameter in the range of 1.1-2.1 µm, and in the range of 4.7-7.0 µm, where the process of aggregation of bacterial cells with organic dust particles takes place. In the case of endotoxins and peptidoglycans we found a gradual increase in the concentrations of particles with aerodynamic diameters in the range of 3.3-11.0 µm. On the basis of the study it can be stated that the working rooms in waste management facility were heavily contaminated with aerosols of bacterial origin. Examination provided the pioneer results for anaerobic bacteria, which were the dominant group. Bacteria that can pose a health risk to exposed workers were also found in the air. The analysis of particle size distribution suggests that the bioaerosols observed in these rooms can accumulate in the middle and upper respiratory tract of employees, causing irritation of the nose and throat.
Źródło:
Rocznik Ochrona Środowiska; 2016, Tom 18, cz. 2; 294-308
1506-218X
Pojawia się w:
Rocznik Ochrona Środowiska
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Transport of Microbial Components in Coarse and Fine Particle Fractions in Office Buildings
Transport cząstek pochodzenia mikrobiologicznego w drobnej i grubej frakcji aerozolu w budynkach biurowych
Autorzy:
Ławniczek-Wałczyk, Anna
Górny, Rafał L.
Powiązania:
https://bibliotekanauki.pl/articles/1812026.pdf
Data publikacji:
2019
Wydawca:
Politechnika Koszalińska. Wydawnictwo Uczelniane
Tematy:
office
endotoxins
β-D-glucans
PM1
PM2.5
PM2.5-10
bioaerosol
biuro
endotoksyny
β-D-glukany
bioaerozol
Opis:
In old and modern interiors, particular attention is focused on the air quality as one of major determinants of the well-being of occupants. Exposure to microbiological contaminants in such close indoor space may be associated with the occurrence of various adverse health outcomes in the exposed individuals. Because the size of inhaled particles determines their place of deposition in the human airways and the associated adverse health outcomes, a detailed characteristic of airborne microbial components carried on fine dust particles in office buildings is needed. The aim of this study was to determine the concentrations of endotoxins, (1-3)-β-D-glucans and culturable microorganisms in coarse, fine and aerosol fractions collected in two office buildings in Warsaw. The concentrations of particulate aerosol were measured using Sioutas impactors in PM1, PM2.5, and PM2.5-10. Kinetic-QCL LAL and Glucatell assays were used to detect endotoxin and (1-3)-β-D-glucan concentrations, respectively. The bioaerosol samples were taken using six-stage Andersen impactor as coarse (> 7-2.1µm) and fine (< 2.1µm) fractions, as well. The mean concentrations of particulate aerosol, endotoxins and (1-3)-β-D-glucans in all studied offices were: in PM1 – 6 μg/m3, 4 EU/m3 and 5 ng/m3; in PM2.5 – 11 μg/m3, 6 EU/m3 and 10 ng/m3; and PM10-2.5 – 3.5 μg/m3, 2 EU/m3 and 2.5 ng/m3, respectively. The concentrations of endotoxins and (1-3)-β-glucans in PM2.5 were significantly higher than in PM10-2.5 (p < 0.01 and p < 0.001, respectively) and accounted for 71% and 84% of their total load in PM10. The airborne bacteria occurred mostly in fine fraction (average 3.9 · 102 CFU/m3, p < 0.01), while fungi in coarse fraction of aerosol (5.6 · 101 CFU/m3). The concentrations of endotoxins showed a positive correlation with PM1 (r = 0.61, p < 0.05) and PM2.5 levels (r = 0.76, p < 0.05) as well as with Gram-negative rods in fine fraction (r = 0.75, p < 0.05). The concentrations of (1-3)-β-D-glucans showed positive correlation with PM2.5 (r = 0.54, p < 0.05) and fungi in fine fraction (r = 0.59, p < 0.05). This study demonstrated that endotoxins and (1-3)-β-D-glucans are associated mostly with fine fraction of aerosol particles. Such particles can penetrate the lower parts of the human respiratory system posing a health risk for exposed people. The main source of endotoxins in the offices were Gram-negative rods. The sources of (1-3)-β-D-glucans were probably both fungal conidia and their fragments of aerodynamic diameters <2.1 μm. The noted concentrations of endotoxins and microorganism were within the range normally observed in this type of facilities. Nevertheless, constant monitoring of the hygienic condition is suggested, including regular cleaning and replacement of air filters in the air-conditioning system.
Zarówno w starych, jak i nowoczesnych wnętrzach budynków biurowych szczególną uwagę zwraca się na jakość powietrza, która jest wyznacznikiem dobrostanu mieszkańców. Narażenie na zanieczyszczenia mikrobiologiczne w takich zamkniętych pomieszczeniach może być związane z pojawianiem się różnych niekorzystnych efektów zdrowotnych u narażonych osób. Ponieważ wielkość wdychanych cząstek determinujeich miejsce osadzania w drogach oddechowych człowieka i związane z tym problemy zdrowotne, potrzebna jest szczegółowa charakterystyka frakcji cząstek pyłowych transportujących cząstki pochodzenia mikrobiologicznego w budynkach biurowych. Celem niniejszego badania było poznanie zakresów stężeń endotoksyn, (1-3)-β-D-glukanów i mikroorganizmów w drobnej i grubej frakcji aerozolu ziarnistego w dwóch budynkach biurowych w Warszawie. Stężenia aerozolu ziarnistego zmierzono przy użyciu impaktorów Sioutas we frakcjach PM1, PM2.5 i PM2.5-10. Testy Kinetic-QCL LAL i Glucatell zastosowano odpowiednio do detekcji endotoksyn i β-D-glukanów. Próbki biaerozolu pobrano przy użyciu sześcio-stopniowego impaktora Andersena we frakcji gruboziarnistej (> 7-2,1 μm) i drobnej (< 2,1 μm). Średnie stężenia aerozolu ziarnistego, endotoksyn i β-D-glukanów w wszystkich badanych biurach wynosiły odpowiednio: w PM1 – 6 μg/m3, 4 JE/m3 i 5 ng/m3; w PM2.5 – 11 μg/m3, 6 JE/m3 i 10 ng/m3 i w PM10-2.5 – 3.5 μg/m33, 2 JE/m3 i 2.5 ng/m3. Stężenia endotoksyn i β-D-glukanów w PM2.5 były znacznie wyższe niż w PM10-2.5 (odpowiednio p < 0.01 i p < 0.001) i stanowiły 71% i 84% frakcji PM10. W badanych pomieszczeniach, bakterie występowały głównie w drobnej frakcji aerozolu (3.9·102 JTK/m3, p < 0.01), podczas gdy grzyby izolowano najczęściej z frakcji gruboziarnistej aerozolu (5.6·101 JTK/m3). Stwierdzono pozytywną korelację pomiędzy stężeniami endotoksyn a stężeniami pyłu PM1 (r = 0.61, p < 0.05) i PM2.5 (r = 0.76, p < 0.05), jak również Gram-ujemnymi pałeczkami (r = 0.75, p < 0.05). Stężenia β-D-glucans wykazały korelację z PM2.5 (r = 0.54, p < 0.05) oraz grzybami w drobnej frakcji (r = 0.59, p < 0.05). Niniejsze badania wykazały, że głównym nośnikiem endotoksyn i (1-3)-β-Dglukanów w pomieszczeniach biurowych były drobne frakcje aerozolu ziarnistego. Cząstki te mogą przenikać do dolnych dróg oddechowych powodując niekorzystne skutki zdrowotne u narażonych osób. Stwierdzono, że głównym źródłem endotoksyn były Gram-ujemne pałeczniki. Źródłami (1-3)-β-D-glukanów były głównie fragmenty strzępek grzybni (lub spor) o aerodynamicznych średnicach <2,1 μm. Odnotowane stężenia endotoksyn i mikroorganizmów w biurach mieściły się w zakresie normalnie obserwowanym w tego typu obiektach. Niemniej jednak sugerowane jest stałe monitorowanie stanu higienicznego tych pomieszczeń, w tym regularne czyszczenie i wymienianie filtrów powietrza w instalacji klimatyzacyjnej.
Źródło:
Rocznik Ochrona Środowiska; 2019, Tom 21, cz. 2; 1099-1115
1506-218X
Pojawia się w:
Rocznik Ochrona Środowiska
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-2 z 2

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies