Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "Dabrowski, D." wg kryterium: Autor


Wyświetlanie 1-4 z 4
Tytuł:
Oczyszczanie odcieków z beztlenowej stabilizacji osadów z oczyszczalni ścieków mleczarskich przy zastosowaniem metody hydrofitowej
Treatment of Reject Water from Anaerobic Sewage Sludge Stabilization in Constructed Wetland
Autorzy:
Dąbrowski, W.
Wiater, J.
Boruszko, D.
Powiązania:
https://bibliotekanauki.pl/articles/1818578.pdf
Data publikacji:
2015
Wydawca:
Politechnika Koszalińska. Wydawnictwo Uczelniane
Tematy:
odcieki
stabilizacja osadów ściekowych
złoża hydrofitowe
reject water
sewage sludge stabilization
constructed wetland
Opis:
The paper presents author's experience related to reject water treatment with constructed wetland (CW). CW technology is well known worldwide to treat municipal wastewater, rainwater and also industrial wastewater. The problem with reject water is mainly concerning high concentration of ammonia nitrogen. It is observed mainly in municipal WWTPs utilizing anaerobic sewage sludge stabilization. Dairy WWTP belonging to Mlekovita was modernized in 2013 with implementation of flotation process in wastewater line and anaerobic stabilization of excess and flotation sludge. Probably this is the biggest dairy WWTP in Poland. It is operating (July 2014) with 6886 m3/d and personal equivalent about 278 000 (project was done for PE 35 0000 and maximum flow 75000 m3/d). Reject water as a byproduct like sewage sludge is returned to the beginning of wastewater line. During own research with reject water it was found that concentration of ammonia nitrogen was varied from 291 N-NH4+/dm3to 423 mg N-NH4+/dm3. while value of BOD5 from 132 to 185 mg O2/dm3. Laboratory scale investigation was carried out with vertical flow CW model with total depth 0,65 m. filled with gravel and sand. Two hydraulic loads were applied during investigations – 0,1 and 0,2 m/d. The temperature during two series was changing from 22,0 do 26,0°C. High efficiency of BOD5 removal (up to 91%) from reject water produced in dairy WWTP was observed. The efficiency of ammonia nitrogen removal was varied from 78,3% to 90,0%. The efficiency of total phosphorus removal was low in both series. Vertical flow constructed wetland can be used as a low cost method to decrease load of dairy WWTP utilizing anaerobic sewage sludge utilization. To increase efficiency of reject water treatment lower hydraulic load (from 0,05 m/d) should be applied. Future researches will be carried out with real scale installation in Wysokie Mazowieckie equipped with special aeration system to supply vertical flow CW with oxygen.
Źródło:
Rocznik Ochrona Środowiska; 2015, Tom 17, cz. 2; 869-879
1506-218X
Pojawia się w:
Rocznik Ochrona Środowiska
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Wpływ nawożenia kompostem z osadów komunalnych na jakość gleby lekkiej pod uprawą wierzby wiciowej w czteroletnim cyklu uprawy
The Effect of Fertilization with Compost from Municipal Sewage Sludge on the Quality of Light Soil under Cultivation of Coppice Willow during Four-year Cycle
Autorzy:
Styszko, L.
Fijałkowska, D.
Dąbrowski, J.
Powiązania:
https://bibliotekanauki.pl/articles/1813863.pdf
Data publikacji:
2017
Wydawca:
Politechnika Koszalińska. Wydawnictwo Uczelniane
Tematy:
gleba
wierzba
nawożenie
kompost
zawartość w próchnicy w glebie
odczyn gleby
soil
willow
fertilization
compost
content of humus in the soil
soil reaction
Opis:
Celem pracy była ocena niektórych zmian w jakości gleby lekkiej w warstwie 0-90 cm, pod uprawą wierzby wiciowej (Salix viminalis) w 4-letnim cyklu, na skutek zastosowania nawożenia kompostem z osadów komunalnych i nawożenia mineralnego. Doświadczenie realizowano w latach 2006-2009 na polu doświadczalnym Politechniki Koszalińskiej w Kościernicy, gmina Polanów (16°24´N i 54°8´E). Doświadczenie założono na glebie lekkiej klasy IVb – V, kompleksu żytniego dobrego, o składzie granulometrycznym piasku gliniastego lekkiego do głębokości 100 cm oraz gliny lekkiej poniżej 100 cm. Czynnikami doświadczenia były: nawożenie (I) – (a) obiekty bez nawożenia, (b) nawożone kompostem z osadów komunalnych (10 t·ha-1 s. m.), (c) nawożone kompostem z osadów komunalnych (10 t·ha-1 s. m.) i azotem mineralnym w ilości 90 kg N·ha-1 oraz (d) nawożone kompostem z osadów komunalnych (10 t·ha-1 s. m.) i azotem mineralnym w ilości 180 kg N·ha-1 oraz klony wierzby wiciowej (II) – 1047, 1054, 1023, 1013, 1052, 1047D, 1056, 1033 i 1018. Kompost charakteryzował się: pHKCl – 6,63, zawartość suchej masy – 68,42%, a zawartość w suchej masie wyniosła: materii organicznej – 39,06%, N – 1,75%, P – 1,60%, K – 0,112%, Ca – 3,426% i Mg – 0,325%. Kompost zastosowano wiosną 2006 roku, a nawóz azotowy wysiewano corocznie przed ruszeniem wegetacji wierzby w latach 2006-2009. Poletko miało powierzchnię 34,5 m2, na którym wysadzono 120 zrzezów (34782 sztuk· ha-1). Corocznie po zakończeniu wegetacji wierzby pobierano z każdego poletka próby gleby z trzech głębokości: 0-30 cm, 31-60 cm i 61-90 cm. Analiza gleby po zakończeniu wegetacji wierzby po pierwszym (2006 r.), po drugim (2007 r.), po trzecim (2008 r.) oraz po czwartym roku (2009) obejmowała ocenę na zawartość: suchej masy, próchnicy i węgla organicznego, azotu ogólnego, amonowego, azotanowego i mineralnego oraz odczynu gleby. Badania wykazały, w miarę upływu lat odstania pędów wierzby malała zawartość w glebie azotu ogólnego, azotanowego i mineralnego, a wzrastała zawartość azotu amonowego, węgla organicznego i próchnicy. Nawożenie wierzby kompostem z osadów komunalnych zwiększało zawartość w glebie próchnicy i węgla organicznego oraz podnosiło odczyn gleby, a nie wpływało na zawartość mineralnych form azotu. Stosowanie mineralnego nawożenia azotowego uprawy wierzby energetycznej podnosiło w glebie zawartość azotanów i azotu mineralnego, obniżało odczyn gleby, a nie wpływało na zawartość próchnicy, węgla organicznego, azotu ogólnego i amonowego.
The aim of the study was to evaluate selected changes of the quality of light soil in a layer of 0-90 cm, under cultivation of willow coppice (Salix viminalis) in the 4-year cycle, due to fertilization with compost from municipal sewage sludge and mineral fertilizers. The experiment was carried out in 2006-2009 on the experimental field of Koszalin University of Technology in Kościernica, Polanów municipality (16°24'N and 54°8'E). The experiment was established on light soil of class IVb-V, of good rye complex, and granulometric composition of light loamy sand to a depth of 100 cm and light loam below 100 cm. The experiment factors were: fertilization (I) – (a) objects without fertilization, (b) fertilized with compost from municipal sewage sludge (10 t·ha-1 d.m.), (c) fertilized with compost from municipal sewage sludge (10 t·ha-1 d.m.) and mineral nitrogen in the amount of 90 kg N· ha-1, and (d) fertilized with compost from municipal sewage sludge (10 t· ha-1 d.m.) and mineral nitrogen in the amount of 180 kg N·ha-1 and clones of willow (II) – 1047, 1054, 1023, 1013, 1052, 1047D, 1056, 1033 and 1018. Compost characterized by: pHKCl – 6.63, dry mass content – 68.42%, and content in dry mass was as follows: organic matter – 39.06%, N – 1.75%, P – 1.60%, K – 0.112%, Ca – 3,426% and Mg – 0.325%. Compost was applied in the spring of 2006, and nitrogen fertilizer was applied each year before start of vegetation of willow in the years 2006-2009. The field area was 34.5 m 2, it was planted 120 cuttings (34782) pieces·ha-1. Each year, after vegetation period of willow soil samples were taken from each plot from three depths: 0-30 cm, 31-60 cm, 61-90 cm. Analysis of soil after first (2006), second (2007), third (2008) and fourth year (2009) the willow vegetation periods included assessment of the content of dry matter, humus and organic carbon, total, ammonium, nitrate and mineral nitrogen and soil pH. Studies show that during years of shoots regrowth of willow content of total, nitrate and mineral nitrogen decreased in soil and content of ammonium nitrogen, organic carbon and humus increased. Fertilization of willow with compost from municipal sewage sludge caused increase of the content of humus and organic carbon in soil and raised soil pH. It did not affect the content of mineral nitrogen forms. Fertilization of willow with mineral nitrogen caused increase of nitrate and mineral nitrogen content in the soil, and decrease of soil pH, and did not affect the content of humus, organic carbon, total and ammonium nitrogen.
Źródło:
Rocznik Ochrona Środowiska; 2017, Tom 19; 618-632
1506-218X
Pojawia się w:
Rocznik Ochrona Środowiska
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Wpływ Efektywnych Mikroorganizmów na zmiany zawartości WWA w osadach ściekowych podczas stabilizacji beztlenowej
Influence of Effective Microorganisms Bacteria on the PAHs Content in Sewage Sludge from the Dairy Wastewater Treatment During Anaerobic Stabilization
Autorzy:
Boruszko, D.
Dąbrowski, W.
Piekutin, J.
Wiater, J.
Powiązania:
https://bibliotekanauki.pl/articles/1818588.pdf
Data publikacji:
2015
Wydawca:
Politechnika Koszalińska. Wydawnictwo Uczelniane
Tematy:
wielopierścieniowe węglowodory aromatyczne
mleczarskie osady ściekowe
efektywne mikroorganizmy
polycyclic aromatic hydrocarbons
dairy sewage sludge
effective microorganisms bacteria
Opis:
There is a leak of information in literature about anaerobic stabilization of sewage sludge from dairy wastewater treatment plants (WWTPs). Different population of microorganisms are responsible for anaerobic sewage sludge stabilization. Own research were focused on using effective microorganisms (EM) invented by Teuro Higa for anaerobic stabilization. Sewage sludge was taken from dairy WWTP belonging to Mlekovita Cooperative in Wysokie Mazowieckie. It was mixture of excess and flotation sludge from pre-treatment of dairy sewage. Researches were conducted with laboratory scale model with two reactors – one was supplied with EM. Before stabilization average value of 16 PAHs was 0,690 μg·g-1 DM. It was found that trinuclear fraction was 46,4% of total PAHs and four nuclear 35,2% of total PAHs. General tendency of PAHs changes during anaerobic stabilization in both reactors(with and without EM) was similar. In first part of anaerobic stabilization (acid fermentation) after seven days it was observed increasing of total PAHs in reactor with and without EM. The sum of PAHs in reactor with EM was 1,125 μg· g-1 DM while in the other reactor without EM it was 1,201 μg· g-1 DM. This is typical for first part of sewage sludge anaerobic stabilization process. Addition of EM did not inhibited of PAHs release and during hydrolysis higher concentration of PAHs sum was observed due to concentration in raw sewage sludge. After two weeks’ time of anaerobic stabilizations decreasing of total sum of PAHs was observed due to concentration after first week of stabilization. It was smaller in reactor without EM .In the last part of sewage sludge stabilization decrease of most checked hydrocarbons was observed. Total concentration of PAHs in sewage sludge without EM was decreased up to 30,5% due to initial concentration. It was 0,479 μg· g-1 DM. In sewage sludge with EM it was decreasing up to 0,172 μg· g-1 DM (75,1% decrease). It was proved that using EM in anaerobic sewage sludge stabilization was responsible for decreasing of PAHs concentration.
Źródło:
Rocznik Ochrona Środowiska; 2015, Tom 17, cz. 2; 914-930
1506-218X
Pojawia się w:
Rocznik Ochrona Środowiska
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Ustalenie warunków technologicznych pracy podczyszczalni ścieków palarni kawy MK-Cafe w Skibnie
Determining of technological conditions of sewage pre-treatment from coffee roasting plant in Skibno
Autorzy:
Dąbrowski, J.
Dąbrowski, T.
Kościelnik, B.
Malej, J.
Piecuch, T.
Piekarski, J.
Kościerzyńska-Siekan, G.
Chanulak, D.
Wolski, H
Powiązania:
https://bibliotekanauki.pl/articles/1826310.pdf
Data publikacji:
2000
Wydawca:
Politechnika Koszalińska. Wydawnictwo Uczelniane
Tematy:
podczyszczalnia ścieków
skład jakościowy ścieków
palarnia kawy
Opis:
Od kwietnia 1999 trwają prace badawcze nad ustaleniem warunków quasi optymalnych pracy układu technologicznego podczyszczalni ścieków w Palarni Kawy w Skibnie prowadzone przez Katedrę Technologii Wody, Ścieków i Odpadów Politechniki Koszalińskiej. Zaprojektowany w Katedrze i wybudowany układ jak na schemacie maszynowym rys. 1 [1] został przedstawiony fragmentarycznie na fotografii 1 oraz na fotografii 2 fragment hali podczyszczalni ścieków. Według technologii ścieki surowe wprowadza się do zbiornika koagulacyjnego - rys. 1 o pojemności roboczej 5m3. Zbiornik ten ma zainstalowane wolnoobrotowe mieszadło z falownikiem. W celu zdekantowania jak największej ilości cieczy nadosadowej zbiornik posiada trzy poziomy przelewowe. Po 24 godzinnym procesie sedymentacji przelew odprowadza się do rząpia, a wylew - na filtr grawitacyjny piaskowy. Następnie ciecz nadosadowa zawracana jest pompą do zbiornika koagulacyjnego, gdzie poddawana jest procesowi napowietrzania. Po procesie napowietrzania i sedymentacji ciecz nadosadowa kierowana jest do procesu filtracji, po czym przechodzi na kolumnę sorpcyjną. Celem niniejszej publikacji jest przedstawienie ostatecznych wyników badań przeprowadzonych w tym układzie w Palarni Kawy MK-Cafe w Skibnie. W trakcie wielu badań [1,3] stwierdzono istotną różnicę składu jakościowego ścieków popłucznych. Wynika to z faktu, że w Palarni Kawy w Skibnie są przetwarzane dwa rodzaje kawy: Robusta - o gorszej charakterystyce wskaźników zanieczyszczeń ścieku (większy ładunek zanieczyszczeń), na którym przeprowadzono badania przedstawione w tej publikacji oraz Arabica - o charakterystyce zanieczyszczeń łatwiejszej do oczyszczenia (mniejszy ładunek zanieczyszczeń). W tabeli 1 przedstawiono wskaźniki zanieczyszczeń ścieku surowego zbliżonego do najgorszego ścieku otrzymywanego w procesie produkcyjnym w Palarni Kawy w Skibnie.
Research work, done by the Division of Water, Wastewater and Wastes Technology, on determining quasi-optimal conditions of work of technological system of sewage from Coffee Roasting Plant in Skibno pre-treatment has been going on since April 1999. The system designed in the Division and built according to the machine diagram (Fig. 1) [1] is shown fragmentarily on photograph 1 and fragment of sewage pretreatment hall on photograph 2. According to technology the raw sewage is poured into coagulation tank, Fig. 1, with working volume of 5 m3. This tank has a slow rotary mixer with inverter installed inside. In order to decant as much sedimentation water as possible, the tank has been furnished with three overflow levels. After 24 hours of sedimentation clarified water is poured into a concrete tank, and sludge on gravitational sand filter. Then the clarified water is pumped back to the coagulation tank, where it is aerated. After aeration process the clarified water is directed to the filter and then it goes to the sorptional column. Technological hall has a steel construction with 4x4x4.5 m of dimensions. Roof and walls are made of PW-8 plates. Investment costs of building part came to 67.000 zł. Building works were made by STOLREM - Koszalin Company. Investment costs of machine part, that is: coagulation tank, filtration column, sorptional column, pumps came to about 52.000 zł. Devices were made by EKOTECHNIKA - Koszalin Company. So the total investment cost came to 119.000 zł - in prices from first half of 1999. During many tests essential difference of qualitative composition of post rinsing wastewater was revealed. This results from the fact, that in the Coffee Roasting Plant in Skibno two kinds of coffee are produced: Arabica - with worse characteristics of wastewater contamination indexes (higher contaminants load), which was treated during research presented in this paper, and Robusta - with contamination characteristics easier to remove (lower contaminants load). Raw wastewater, which characteristics is shown in Table 1, is first treated using coagulation process in coagulation tank 1 (Photo 1). Bentonite and calcium hydroxide Ca(OH)2 are used as coagulants. Reagents dose depends on the kind of post-rinsing wastewater. For more polluted wastewater dose of reagents is: 2 kg Ca(OH)2/m3 of wastewater and 0.2 kg bentonite/m3 of wastewater. For the wastewater with lower contaminants load dose of reagents is: 1 kg Ca(OH)2/m3 of wastewater and 0.2 kg bentonite/m3 of wastewater. After 24 hours of sedimentation process decanted sedimentation water is directed to the filtration process, and then sorption process. Filtration column 2 (Photo 1) with 0.75 m of height, is filled with gravel which grains diameter is in the range of 0,5÷1,2 mm. The sorption process 3 (Photo 1) is conducted on the active carbon WA 1÷4. Columns are washed with technological water, what for sure has influence on results worsening. Post coagulation sludge from the tank is directed to the gravitation sand filter 4 (Photo 1) with area of 4 m2. Outflow was not analysed, it is directed back to the coagulation process along with raw wastewater from production. During conducting research it turned out, that correction of pH index is necessary. Excessive value of pH index is caused by calcium hydroxide usage, which increases precipitation of metals hydroxides and other sediments increasing pH value at the same time [2]. This problem is solved using wastewater aeration, when CO2 as a acid anhydride causes decrease of pH value. Wastewater are aerated eight hours. Conducted research allows to draw certain general conclusions: Technological system for post-rinsing sewage pre-treatment in the Coffee Roasting Plant in Skibno with the highest contaminants load requires application of filtration bed before sorption process, To reduce sewage pollution index - pH it is necessary to apply aeration, The stuff of the wastewater pre-treatment plant cannot let the filtration bed and the sorptional bed dry up - it always has to be flooded with wastewater or water, All indexes of raw sewage pollution have reached standard values, allowing to pipe off sewage to open reservoirs and ground waters.
Źródło:
Rocznik Ochrona Środowiska; 2000, Tom 2; 114-123
1506-218X
Pojawia się w:
Rocznik Ochrona Środowiska
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-4 z 4

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies