Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "flat plate" wg kryterium: Temat


Wyświetlanie 1-4 z 4
Tytuł:
Comparing the efficiency of evacuated tube and flat-plate solar collectors in real installation conditions
Autorzy:
Jurczak, Marlena Anna
Skotnicka-Siepsiak, Aldona
Powiązania:
https://bibliotekanauki.pl/articles/2065635.pdf
Data publikacji:
2020
Wydawca:
Politechnika Częstochowska
Tematy:
flat plate solar collectors
evacuated tube collectors
efficiency of solar collectors
płaskie kolektory słoneczne
kolektory rurowe
sprawność kolektorów słonecznych
Opis:
The subject of the work is an analysis of two types of solar collectors: flat-plate and evacuated tube collectors in the same, natural working conditions during the period from 1st May 2017 to 30th September 2017. The scope of work includes a descriptive presentation of a measuring setup, located on the roof of the building of the Construction University of Warmia and Mazury in Olsztyn, and also the research methodology, as well as an analysis of the results and conclusions obtained. The measurements allow a comparison of the efficiency of the flat-plate and evacuated tube collectors by calculating heat yields, based on the following variants: average hourly irradiation, outdoor air temperature, temperature of the medium supplying the collectors and temperature of the returning medium. An analysis of the heat yield was made in relations to the individual absorber surface, to determine which of the tested collectors showed higher efficiency under real operating conditions during the spring-summer period.
Źródło:
Budownictwo o Zoptymalizowanym Potencjale Energetycznym; 2020, 9, 2; 31--38
2299-8535
2544-963X
Pojawia się w:
Budownictwo o Zoptymalizowanym Potencjale Energetycznym
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
The calculation of flat plate systems taking into account seismic action
Obliczenia płyt stropowych płaskich przy uwzględnieniu obciążeń sejsmicznych
Autorzy:
Avagyan, H.
Powiązania:
https://bibliotekanauki.pl/articles/2065470.pdf
Data publikacji:
2016
Wydawca:
Politechnika Częstochowska
Tematy:
flat plate
reinforced concrete
seismic load
bending moment
axial force
płyty płaskie
konstrukcje żelbetowe
obciążenia sejsmiczne
momenty zginające
siły osiowe
Opis:
The four storey in situ reinforced concrete frame-wall building by flat plate system is presented in the article, which under static and seismic loads was calculated. Only the middle column of the building in the paper was reviewed and all computations by LIRA were done. The calculations according to Armenian and Russian building codes were implemented and satisfied these conditions. The supremum and infimum bending moments and axial forces of column for flat plate analyses were determined and compared. At the same time there were carried out computations taking into account the punching shear action of slabs. The results are shown that the differences of axial forces between static and dynamic loads are negligible, however of the volume of punching shear is huge enough.
W artykule przedstawiono istniejący budynek czterokondygnacyjny o żelbetowej konstrukcji szkieletowej słupowo-płytowej, do którego obliczeń przyjęto wpływ obciążeń statycznych oraz sejsmicznych. W opracowaniu omówiono słup środkowy, a analizy obliczeniowej dokonano za pomocą programu obliczeniowego LIRA. Analizę wykonano na podstawie norm armeńskich oraz rosyjskich, a otrzymane wyniki spełniają założenia obu norm. W celu przeprowadzenia analiz płyty płaskiej określono i porównywano obwiednie momentów zginających oraz sił osiowych słupa. Przeprowadzono również obliczenia mające na celu sprawdzenie nośności płyty na przebicie. W wyniku analizy stwierdzono, że różnice sił osiowych wyznaczonych przy uwzględnieniu obciążeń statycznych oraz dynamicznych są niewielkie, jednakże róż- nice wielkości nośności na przebicie są dość duże.
Źródło:
Budownictwo o Zoptymalizowanym Potencjale Energetycznym; 2016, 2 (18); 15--20
2299-8535
2544-963X
Pojawia się w:
Budownictwo o Zoptymalizowanym Potencjale Energetycznym
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
The stress–strain state estimation of slabs with shear reinforcement according to Armenian and foreign building codes
Badanie stanu naprężenie–odkształcenie zbrojonych płyt poddanych ścinaniu na podstawie ormiańskich i obcojęzycznych norm budowlanych
Autorzy:
Avagyan, H.
Powiązania:
https://bibliotekanauki.pl/articles/2067949.pdf
Data publikacji:
2018
Wydawca:
Politechnika Częstochowska
Tematy:
seismic action
finite element method
building codes
flat plate
shear reinforcement
oddziaływanie sejsmiczne
metoda elementów skończonych
normy budowlane
płaska płyta
zbrojenie na ścinanie
Opis:
The paper presents the results of punching shear values with reinforcement based on calculations of two and four storey cast–in–place reinforced concrete flat plate system buildings with spans of 4 and 7 m in accordance with Armenian, Russian, European and American building codes under seismic action. The effect of punching shear on both interior and edge columns was carried out. All calculations by LIRA, Design Expert and RCM ACI–builder softwares were implemented. In contrast to Eurocode 2 (EN 2) and American Concrete Institute (ACI), the building codes of the Republic of Armenia (SNiP) do not include the influence of bending moment in shear stress equation. To analyze the systems finite element method (FEM) was used. The results of comparison analyses shown that according to SNiP the shear stresses do not exceed the limit even without reinforcement, whereas by foreign standards the differences between peak shear stresses with reinforcement and permissible shear reinforcement are marginal. To conclude, in shear stress condition the internal bending moments have a significant role, especially in seismic regions.
W artykule przedstawiono wyniki pomiarów wytrzymałości na ścinanie w oparciu o obliczenia dla dwu i czteropiętrowych budynków żelbetowych o rozpiętości 4 i 7 m, zgodnie z ormiańskimi, rosyjskimi, europejskimi i amerykańskimi normami budowlanymi, w strefie oddziaływań sejsmicznych. Przeprowadzono badania dotyczące przebicia zarówno dla słupów wewnętrznych, jak i narożnych. Wszystkie obliczenia wykonano w programach LIRA, Design Expert i RCM ACI–builder. W przeciwieństwie do Eurokodu 2 (EN 2) oraz American Concrete Institute (ACI) przepisy budowlane Republiki Armenii (SNiP) nie uwzględniają wpływu momentu zginającego na równanie dla naprężeń stycznych. Do analizy układów konstrukcyjnych wykorzystano metodę elementów skończonych (MES). Wyniki analiz porównawczych wykazały, że zgodnie z SNiP naprężenia ścinające nie przekraczają wartości granicznych nawet bez użycia zbrojenia, podczas gdy według norm obcojęzycznych różnice pomiędzy ekstremalnymi naprężeniami ścinającymi z użyciem zbrojenia a dopuszczalnym ścinaniem zbrojenia są marginalne. Podsumowując, dla warunków dotyczących naprężenia ścinającego wewnętrzne momenty zginające mają duże znaczenie, zwłaszcza na obszarach objętych oddziaływaniami sejsmicznymi.
Źródło:
Zeszyty Naukowe Politechniki Częstochowskiej. Budownictwo; 2018, 24 (174); 13-18
0860-7214
Pojawia się w:
Zeszyty Naukowe Politechniki Częstochowskiej. Budownictwo
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
The comparison analyses of nonlinear calculations of flat plate systems with and without shear reinforcement
Analiza porównawcza nieliniowych obliczeń systemów płaskich płyt ze zbrojeniem i bez zbrojenia
Autorzy:
Dadayan, T.
Karapetyan, L.
Avagyan, H.
Powiązania:
https://bibliotekanauki.pl/articles/2067952.pdf
Data publikacji:
2018
Wydawca:
Politechnika Częstochowska
Tematy:
reinforced concrete structures
flat plate
nonlinear analyses
finite element method
shear reinforcement
konstrukcje żelbetowe
płyty płaskie
analiza nieliniowa
metoda elementów skończonych
zbrojenie na ścinanie
Opis:
Linear, nonlinear and test comparison analyses of flat plate slabs with shear reinforcement are presented in the article. Analyses of slabs with and without shear reinforcement by nonlinear simulations are introduced. The calculations of slabs without and with 0.16 m eccentricities were performed. For analyses finite element method were used. Design models of flat slab with column by “Lira SAPR” software were carried out. After the calculations whole results with experimental investigations were compared. The comparison analyses were shown, that presence of shear reinforcement far increase the capacity of slabs. Furthermore, the presence of shear reinforcement depends on eccentricity increases the axial force approximately 25%. Moreover, the difference between tests and nonlinear analyses results are about 6.4%.
W artykule przedstawiono liniowe, nieliniowe i doświadczalne analizy porównawcze płaskich płyt stropowych ze zbrojeniem na ścinanie. Przeprowadzono analizy płyt ze wzmocnieniem i bez zbrojenia z wykorzystaniem symulacji nieliniowych. Wykonano obliczenia płyt bez mimośrodów i z mimośrodami 0,16 m. Do analiz wykorzystano metodę elementów skończonych. Wykonano modelowanie płaskiej płyty ze słupem za pomocą oprogramowania "Lira SAPR". Po zakończeniu obliczeń porównano wyniki z badaniami eksperymentalnymi. Analizy porównawcze wykazały, że obecność zbrojenia na ścinanie znacznie zwiększa zdolność płyt do przenoszenia obciążeń. Ponadto obecność zbrojenia na ścinanie zależy od mimośrodowości, a siła osiowa wynosi około 25%. Co więcej, różnica pomiędzy testami i wynikami analiz nieliniowych wynosi około 6,4%.
Źródło:
Zeszyty Naukowe Politechniki Częstochowskiej. Budownictwo; 2018, 24 (174); 60-65
0860-7214
Pojawia się w:
Zeszyty Naukowe Politechniki Częstochowskiej. Budownictwo
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-4 z 4

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies