Tytuł:
Speciation of arsenic in groundwater and technologies for removal of arsenic in drinking water in the spiro tunnel bulkhead, Park City, Utah, USA
Autorzy:
Pawlak, Z.
Rabiega, G.
Scanlan, L.
Cartwright, P.
Powiązania:
https://bibliotekanauki.pl/articles/347045.pdf
Data publikacji:
2003
Wydawca:
Politechnika Bydgoska im. Jana i Jędrzeja Śniadeckich. Wydział Technologii i Inżynierii Chemicznej
Tematy:
arsenic speciation
reverse osmosis treatment
coagulation filtration treatment
water treatment
Opis:
Application of an anion exchange resin column was performed to speciate of arsenic (III) and (V) in drinking water. This methodology was used to analyze water samples collectioned from the study of arsenic removal by two technologies, reverse osmosis membrane filtration and chemical coagulation/ filtration in pilot scale in anticipation of EPA=s new arsenic drinking water standard of 10 µg/L takes effect 2006. This EPA treatment technology project was to collect data on the performance of two existing water treatment processes to remove arsenic on pilot scale. Total arsenic concentrations were reduced by reverse osmosis from an average 60 µg/L in the source water to less than 1 µg/L, and chemical coagulation reduced total arsenic from an average 60 µg/L to 4 µg/L. The work reported here will focus on obtaining accurate readings for arsenic valence states (III) and (V), given the Edwards [17] method for arsenic speciation. Separation of arsenic As(III) and As(V) by speciation in field samples, was performed using an anion exchange resin column. The chloride interferences that affect the determination of 75Arsenic from chloride (35 isotope) molecular species (40Ar35Cl), were corrected using chloride measurements in all samples using equation: [75As(corr)] = [75As] - 3.127 × {[40Ar37Cl] - 0.815 [82Se]}. The use of sulfuric acid in the preservation procedure created interferences with ICP-MS in the range one ěg/L of arsenic. The problem of interference in determination of isotope 75As is due to sulfur 34S isotope which is present in sulfate. The (34S isotope, 4.21%) forms the polyatomic species (mass 75) (40Ar34S1H) and species (mass 74) (40Ar34S) which interferes with the determination of 75As isotope. The method detection limit, MDL, for arsenic for ICP-MS was determined to be 0.1 µg/L. Our spiked matrix recoveries, spiked blank samples, and reference materials deviate only a few percents from the listed true values.
Źródło:
Ars Separatoria Acta; 2003, 2; 71-83
1731-6340
Pojawia się w:
Ars Separatoria Acta
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-1 z 1

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies