Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "pierścień" wg kryterium: Temat


Wyświetlanie 1-2 z 2
Tytuł:
Anatomia diagnostyczna i diagnostyka patologii strefy entezy pierścienia rotatorów
Diagnostic anatomy and diagnostics of enthesal pathologies of the rotator cuff
Autorzy:
Czyrny, Zbigniew
Powiązania:
https://bibliotekanauki.pl/articles/1061620.pdf
Data publikacji:
2012
Wydawca:
Medical Communications
Tematy:
MRI
RM
US
USG
anatomy
enthesopathy
rotator cuff
rm
us
usg
anatomia
entezopatia
pierścień rotatorów
Opis:
Detailed anatomy, crucial in modern high-definition diagnostics imaging, is a base for understanding diagnostic images and the nature of the diagnosed disease. The aim of this paper is presentation of a new anatomical model of the rotator cuff, which includes definition of tendinous and capsule-ligamentous layers as equally important to rotator cuff function understanding. Schematic and diagnostic (ultrasonography, magnetic resonance imaging) anatomy of the rotator cuff based on the core tendon concept is presented. Appropriate tissue layers of the cuff are discussed in detail. In the diagnostics part some enthesal pathologies of the rotator cuff are presented. Material and methods: New anatomical data was analyzed in the context of rotator cuff layers – their presence, thickness and structure observed on magnetic resonance imaging and ultrasonographic images. Conclusions: Rotator cuff should be regarded as a multilayer structure consisting of fused fibers of tendons and capsuloligamentous complex. The thickness of these layers is comparable therefore it is important to realize that capsular pathologies may become a serious obstacle to normal shoulder joint function. Understanding of anatomical rotator cuff layers explains the formation of calcific cavities within the rotator cuff. In fact between layers of the cuff. Calcific cavities are a sequelae of chronic enthesopathy/enthesal tear with hydroxyapatite filling and probably delaminating the tendinous layer from the capsuloligamentous one.
Anatomia szczegółowa, jakiej wymaga nowoczesna diagnostyka obrazowa, jest podstawą zrozumienia obrazów diagnostycznych oraz natury diagnozowanej choroby. Celem pracy jest przedstawienie nowego modelu anatomicznego struktur mięśniowo-ścięgnistych i torebkowo-więzadłowych o kompleksowej nazwie pierścień rotatorów, na podstawie schematów anatomicznych i anatomii diagnostycznej (ultrasonografia i rezonans magnetyczny) pierścienia z zastosowaniem koncepcji rdzeni ścięgnistych. Omawiane są odpowiednie warstwy tkankowe pierścienia rotatorów. W części diagnostycznej przedstawiono niektóre patologie entezy ramiennej pierścienia rotatorów. Materiał i metoda: Przeanalizowano najnowsze dane z badań anatomicznych struktury warstw pierścienia rotatorów – ich lokalizację, wymiary i strukturę w badaniach ultrasonograficznym i rezonansu magnetycznego. Wnioski: Pierścień rotatorów powinien być rozpatrywany jako wielowarstwowa struktura składająca się z przeplatających się i zespalających ze sobą włókien ścięgien i kompleksu torebkowo-więzadłowego spełniających różne funkcje statyczno- dynamiczne. Grubość tych warstw jest porównywalna, stąd duże znaczenie ma świadomość, że patologie kompleksu torebkowo-więzadłowego mogą stać się poważną przeszkodą w prawidłowym funkcjonowaniu stawu ramiennego, mając istotny wpływ na zachowanie się całego pierścienia rotatorów. Zrozumienie anatomii i funkcji warstw pierścienia rotatorów wyjaśnia część zagadki tworzenia się hydroksyapatytowych jam wapiennych pomiędzy warstwami ścięgien/kompleksu. Jamy te są konsekwencją uszkodzeń entezy pierścienia rotatorów na granicy przyczepu warstwy ścięgnistej i torebkowo- więzadłowej. Takie uszkodzenie entezy otwiera drogę do wypełniania już istniejących rozwarstwień ścięgna-kompleksu oraz aktywnego ich rozlaminowywania poprzez ciągłe wypełnianie materiałem wapiennym.
Źródło:
Journal of Ultrasonography; 2012, 12, 49; 178-187
2451-070X
Pojawia się w:
Journal of Ultrasonography
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Inter-rater reliability in the classification of supraspinatus tendon tears using 3D ultrasound – a question of experience?
Zgodność oceny stopnia uszkodzenia ścięgna mięśnia nadgrzebieniowego w ultrasonografii 3D – kwestia doświadczenia?
Autorzy:
Tamborrini, Giorgio
Marx, Christian
Micheroli, Raphael
Powiązania:
https://bibliotekanauki.pl/articles/1052514.pdf
Data publikacji:
2016
Wydawca:
Medical Communications
Tematy:
3D ultrasound
inter-rater reliability
odtwarzalność
pierścień rotatorów
reproducibility
shoulder rotator cuff
ultrasonografia
ultrasonografia 3D
ultrasound
zgodność ocen
Opis:
Background: Three-dimensional (3D) ultrasound of the shoulder is characterized by a comparable accuracy to two-dimensional (2D) ultrasound. No studies investigating 2D versus 3D inter-rater reliability in the detection of supraspinatus tendon tears taking into account the level of experience of the raters have been carried out so far. Objectives: The aim of this study was to determine the inter-rater reliability in the analysis of 3D ultrasound image sets of the supraspinatus tendon between sonographer with different levels of experience. Patients and methods: Non-interventional, prospective, observational pilot study of 2309 images of 127 adult patients suffering from unilateral shoulder pain. 3D ultrasound image sets were scored by three raters independently. The intra-and interrater reliabilities were calculated. Results: There was an excellent intra-rater reliability of rater A in the overall classification of supraspinatus tendon tears (2D vs 3D κ = 0.892, pairwise reliability 93.81%, 3D scoring round 1 vs 3D scoring round 2 κ = 0.875, pairwise reliability 92.857%). The inter-rater reliability was only moderate compared to rater B on 3D (κ = 0.497, pairwise reliability 70.95%) and fair compared to rater C (κ = 0.238, pairwise reliability 42.38%). Conclusions: The reliability of 3D ultrasound of the supraspinatus tendon depends on the level of experience of the sonographer. Experience in 2D ultrasound does not seem to be sufficient for the analysis of 3D ultrasound imaging sets. Therefore, for a 3D ultrasound analysis new diagnostic criteria have to be established and taught even to experienced 2D sonographers to improve reproducibility.
Wprowadzenie: Ultrasonografia trójwymiarowa (3D) barku jest uznawana za metodę o porównywalnej dokładności w stosunku do ultrasonografii dwuwymiarowej (2D). Jak dotąd nie przeprowadzono żadnego badania porównującego ultrasonografię 2D i 3D w diagnostyce zerwania ścięgna mięśnia nadgrzebieniowego z uwzględnieniem poziomu doświadczenia badaczy. Cele: Celem niniejszego badania było porównanie oceny patologii ścięgna nadgrzebieniowego za pomocą badania 3D pomiędzy operatorami o różnym poziomie doświadczenia. Pacjenci i metody: Pilotażowe nieinterwencyjne, prospektywne, obserwacyjne badanie 2309 obrazów uzyskanych z badań 127 dorosłych pacjentów cierpiących z powodu jednostronnego bólu barku. Zestawy obrazów 3D zostały ocenione w sposób niezależny przez trzech badaczy. Obliczono poziom zgodności pomiędzy badaczami oraz świadozgodność ocen jednego badacza. Wyniki: Badacz A wykazał się bardzo wysokim poziomem zgodności swoich ocen w ogólnej klasyfikacji zerwania ścięgna mięśnia nadgrzebieniowego (2D vs 3D κ = 0,892, porównywalność parami 93,81%, runda ocen obrazów 3D nr 1 vs runda ocen obrazów 3D nr 2 κ = 0,875, porównywalność parami 92,857%). Zgodność pomiędzy badaczami była tylko umiarkowana w porównaniu z badaczem B (obrazy 3D) (κ = 0,497, porównywalność parami 70,95%) i przeciętna w porównaniu z badaczem C (κ = 0,238, porównywalność parami 42,38%). Wnioski: Wiarygodność interpretacji obrazów 3D ścięgna mięśnia nadgrzebieniowego jest zależna od poziomu doświadczenia operatora. Doświadczenie w ultrasonografii 2D zdaje się być niewystarczające do analizy zestawów obrazów 3D. Z tego powodu należy opracować nowe kryteria diagnostyczne dla analizy obrazów 3D i wprowadzić nauczanie interpretacji badań ultrasonografii trójwymiarowej, aby w ten sposób zwiększyć poziom odtwarzalności.
Źródło:
Journal of Ultrasonography; 2016, 16, 66; 252-259
2451-070X
Pojawia się w:
Journal of Ultrasonography
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-2 z 2

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies