Effect of the magnetic particles concentration on the ferro-oil’s dynamic viscosity in presence of an external magnetic field in the aspect of shear rate’s variations
Autorzy:
Frycz, M.
Horak, W.
Powiązania:
https://bibliotekanauki.pl/articles/246160.pdf
Data publikacji:
2013
Wydawca:
Instytut Techniczny Wojsk Lotniczych
Tematy:
ferro-oil
dynamic viscosity
magnetic particles concentration
rheometer
slide journal bearings
Opis:
The purpose of this study is to determine the effect of changes in the concentration of magnetic particles in ferrooil to change its physical properties, in particular the dynamic viscosity in a constant external magnetic field in terms of changes in shear rate and changes in the intensity of that field. Rheological studies were carried out on Physica MCR 301 rheometer in the “plate -plate” measurement system with an adapter to magneto-rheological studies MRD 180/1T. The applied adapter enable to obtain almost homogeneous distribution of magnetic field strength. Thermal stabilization was carried out by a water jacket in a closed chamber and controlling the nature of the magnetic field was conducted by current’s changes. Tests were performed for shear rate’s changes from 0 to 1000 1/s as regards changes an external magnetic field intensity 0–700 mT. The selected concentrations of magnetic particles in a ferro-oil were 1, 2, 4, 6 and 8% and the tested ferrofluid was product of FerroTec of Unterensingen (Germany), which is a mixture of colloidal mineral motor oil Penzzoil’s LongLife Gold's SAE 15W-40 with Fe3O4 magnetic particles and the surfactant. The paper presents, in the form of graphs, the changes of ferro-oil’s dynamic viscosity as a function of shear rate and concentration of magnetic particles in the aspect of external magnetic field’s intensity changes. The results of research were also subjected to analysis. The obtained characteristics of ferro-oil’s viscosity show clear evidence of non-Newtonian properties of the liquids. There is observed progression of these properties with increasing of magnetic particles concentration. This fact indicates the essential effect of the addition mentioned particles to the change of the ferro-oil’s viscosity characteristics.
Źródło:
Journal of KONES; 2013, 20, 3; 139-144
1231-4005
2354-0133
Pojawia się w:
Journal of KONES
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Effect of the magnetic particles concentration on the ferro-oil’s dynamic viscosity in presence of an external magnetic field in the aspect of temperature changes
Autorzy:
Czaban, A.
Frycz, M.
Horak, W.
Powiązania:
https://bibliotekanauki.pl/articles/247080.pdf
Data publikacji:
2013
Wydawca:
Instytut Techniczny Wojsk Lotniczych
Tematy:
ferro-oil
dynamic viscosity
magnetic particles concentration
temperature changes
external magnetic field
Opis:
There is presented an effect of the changes of the concentration of magnetic particles included in the ferro-oil on its dynamic viscosity in the presence of external magnetic field in this paper. The study was conducted in the context of temperature’s changes. The authors assume that the concentration of magnetic particles in ferro-oil can significantly affects its basic physical properties as dynamic viscosity, as well as the operational properties of journal sliding bearings ferro-oil’s lubricated. The equally significant as the above mentioned properties may affect the external environmental conditions of operation, especially temperature changes. In this context, an important technique’s issue appears to determine the principles of selection of optimal concentration of above mentioned particles according to the existing environmental conditions of its operation, or the expectations laid against the operation of the devices. Rheological studies were carried out on Physica MCR 301 rheometer in the “plate-to-plate” measurement system with an adapter to magneto-rheological studies MRD 180/1T. Thermal stabilization was carried out by a water jacket in a closed chamber and controlling the nature of the magnetic field was conducted by current’s changes. Tests were performed for four selected temperature range of 60º, 70º, 80º and 90ºC as regards changes an external magnetic field intensity 0-700 mT. The selected concentrations of magnetic particles in a ferro-oil were 1, 2, 4, 6 and 8%.
Źródło:
Journal of KONES; 2013, 20, 2; 55-60
1231-4005
2354-0133
Pojawia się w:
Journal of KONES
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-2 z 2

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies