Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "occupational contact dermatitis" wg kryterium: Temat


Wyświetlanie 1-8 z 8
Tytuł:
Occupational exposure to propranolol: A rarely recognised cause of allergic contact dermatitis
Autorzy:
Ali, Faisal R.
Shackleton, David B.
Kingston, Timothy P.
Williams, Jason D.
Powiązania:
https://bibliotekanauki.pl/articles/2177357.pdf
Data publikacji:
2015-05-13
Wydawca:
Instytut Medycyny Pracy im. prof. dra Jerzego Nofera w Łodzi
Tematy:
allergic contact dermatitis
occupational contact dermatitis
propranolol
beta blocker
Źródło:
International Journal of Occupational Medicine and Environmental Health; 2015, 28, 3; 639-640
1232-1087
1896-494X
Pojawia się w:
International Journal of Occupational Medicine and Environmental Health
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Occupational allergic and irritant contact dermatitis in workers exposed to polyurethane foam
Autorzy:
Kieć-Świerczyńska, Marta
Świerczyńska-Machura, Dominika
Chomiczewska-Skóra, Dorota
Nowakowska-Świrta, Ewa
Kręcisz, Beata
Powiązania:
https://bibliotekanauki.pl/articles/2178820.pdf
Data publikacji:
2014-05-17
Wydawca:
Instytut Medycyny Pracy im. prof. dra Jerzego Nofera w Łodzi
Tematy:
polyurethanes
isocyanates
4’-diphenylmethane diisocyanate (MDI)
diaminodiphenylmethane (MDA)
occupational contact dermatitis
Opis:
Objectives: To evaluate sensitization to chemicals present in work environment after an outbreak of contact dermatitis in workers of vehicle equipment factory, exposed to polyurethane foam, based on 4,4'-diphenylmethane diisocyanate (MDI). Material and Methods: From among 300 employees, 21 individuals reporting work-related skin and/or respiratory tract symptoms underwent clinical examination, patch testing, skin prick tests, spirometry and MDI sIgE measurement in serum. Patch tests included isocyanates series, selected rubber additives, metals, fragrances, preservatives, and an antiadhesive agent. Results: Clinical examination revealed current eczema in the area of hands and/or forearms in 10 workers. Positive patch test reactions were found in 10 individuals, the most frequent to diaminodiphenylmethane and 4-phenylenediamine (7 persons). Reactions to an antiadhesive agent were assessed as irritant (5 workers). Except for sensitization to common aeroallergens, no significant abnormalities were found in the remaining tests. Occupational allergic contact dermatitis was diagnosed in 7 workers, irritant contact dermatitis in 10 and coexisiting allergic and irritant contact dermatitis in 3 workers. Conclusions: In workers manufacturing products from polyurethane foam, attention should be paid to the risk of developing contact dermatitis. Skin problems in our study group were attributable probably to insufficient protection of the skin.
Źródło:
International Journal of Occupational Medicine and Environmental Health; 2014, 27, 2; 196-205
1232-1087
1896-494X
Pojawia się w:
International Journal of Occupational Medicine and Environmental Health
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Occupational contact allergy to omeprazole and ranitidine
Autorzy:
Herrera-Mozo, Inmaculada
Sanz-Gallen, Pere
Martí-Amengual, Gabriel
Powiązania:
https://bibliotekanauki.pl/articles/2164096.pdf
Data publikacji:
2017-05-16
Wydawca:
Instytut Medycyny Pracy im. prof. dra Jerzego Nofera w Łodzi
Tematy:
occupational exposure
occupational contact dermatitis
proton pump inhibitors
ranitidine
omeprazole
active pharmaceutical ingredients
Opis:
Omeprazole is a proton pump inhibition and ranitidine is an H2 histamine receptor antagonist widely used in the treatment of gastroesophageal reflex disease, peptic ulcer disease, Zollinger-Ellison syndrome and as a protector of the gastric mucosae. We report a case of occupational contact allergy to omeprazole and ranitidine. A 48-year-old man, with no pre-existing history of atopy or lifestyle factors. He neither had any medical history of consumption of drugs such as ranitidine and omeprazole. He worked for 19 months in the pharmaceutical company that manufactured ranitidine base. He presented rash in the face and eczema on the dorsum of the hands with itching. The study by prick tests with ranitidine gave negative response. Patch testing with ranitidine base and ranitidine hydrochloride gave positive response. A month later, when the patient was asymptomatic he returned to the pharmaceutical company, being switched from this previous job to the reactor manufacturing omeprazole. A few days after that, he presented erythematous eruptions involving face and neck with itching. Prick tests, path tests and in vitro laboratories studies with omeprazole gave positives. In this case the patient presented hypersensitivity type I at omeprazole and hypersensitivity type IV at omeprazole and ranitidine. Our aportation indicates the importance of careful analysis of the occupational exposure histories of patients with the suspected type I or type IV hypersensitivity to allergens, to determine whether work exposure is the cause. Med Pr 2017;68(3):433–435
Źródło:
Medycyna Pracy; 2017, 68, 3; 433-435
0465-5893
2353-1339
Pojawia się w:
Medycyna Pracy
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Severe facial reaction to thiurams in surgeons
Autorzy:
Coppeta, Luca
Papa, Francesca
Pietroiusti, Antonio
De Zordo, Ludovico M.
Perrone, Stefano
Barone, Silvia
Magrini, Andrea
Powiązania:
https://bibliotekanauki.pl/articles/2162627.pdf
Data publikacji:
2019-02-28
Wydawca:
Instytut Medycyny Pracy im. prof. dra Jerzego Nofera w Łodzi
Tematy:
occupational dermatitis
allergy
contact dermatitis
concomitant contact sensitization
occupational allergens
thiurams
Opis:
Contact dermatitis is a major problem in the healthcare environment and in other sectors. Healthcare professionals may be exposed to a large number of chemical agents, including the accelerators for rubber vulcanization process. The prevalence of allergic contact dermatitis among operators in the sector ranges 13–30%. This paper describes the case of a 46-year-old male cardiac surgeon affected by a severe skin reaction localized on the face in the absence of hand dermatitis, presumably resulting from the use of a surgical patch applied to the face. Patch tests were performed and the result was negative for latex and positive (+++) for thiuram mix. A thiuram-free tape was prescribed and the operator’s dermatitis improved significantly. Thus, it would be very important to pay attention to skin disorders in health workers and thiuram as an occupational allergen. Med Pr. 2019;70(1):121–4
Źródło:
Medycyna Pracy; 2019, 70, 1; 121-124
0465-5893
2353-1339
Pojawia się w:
Medycyna Pracy
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Direct and airborne contact dermatitis in a beekeeper from the Małopolska region
Autorzy:
Basista, Katarzyna
Powiązania:
https://bibliotekanauki.pl/articles/2180078.pdf
Data publikacji:
2012-09-01
Wydawca:
Instytut Medycyny Pracy im. prof. dra Jerzego Nofera w Łodzi
Tematy:
allergic contact dermatitis
propolis
beekeepers
occupational diseases
occupational allergy
airborne contact dermatitis
Opis:
The paper describes an atypical case of simultaneous airborne and direct contact dermatitis in a beekeeper from the Małopolska region. This is the third such case described in a beekeeper in the world and the fi rst in Poland. I suggest that propolis should be regarded as both a direct and airborne contact allergen in beekeepers.
Źródło:
International Journal of Occupational Medicine and Environmental Health; 2012, 25, 4; 499-500
1232-1087
1896-494X
Pojawia się w:
International Journal of Occupational Medicine and Environmental Health
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Airborne contact dermatitis and asthma in a nail art operator
Autorzy:
Vaccaro, Mario
Guarneri, Fabrizio
Barbuzza, Olga
Cannavò, Serafinella P.
Powiązania:
https://bibliotekanauki.pl/articles/2178806.pdf
Data publikacji:
2014-01-01
Wydawca:
Instytut Medycyny Pracy im. prof. dra Jerzego Nofera w Łodzi
Tematy:
occupational asthma
acrylates
airborne allergic contact dermatitis
nail art
Opis:
Nail art (creation and decoration of artificial nails) is a growing fashion trend. Proportionally to its popularity, the number of allergic reactions to the materials used has recently increased. We report the case of a nail art operator who developed occupational allergy to acrylates, manifested with the unusual simultaneous presence of asthma and dermatitis. Cutaneous lesions only affected areas not covered by individual protection devices or clothes, even if such areas were not in direct contact with acrylates, suggesting airborne allergic contact dermatitis. While respiratory problems were solved with the correct use of a mask at the workplace, facial dermatitis proved impossible to avoid or control and, for this reason, the patient had to change her work.
Źródło:
International Journal of Occupational Medicine and Environmental Health; 2014, 27, 1; 137-140
1232-1087
1896-494X
Pojawia się w:
International Journal of Occupational Medicine and Environmental Health
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Molecular profile of sensitization in subjects with short occupational exposure to latex
Autorzy:
Lamberti, Monica
Buonanno, Rosaria
Ritonnaro, Chiara
Giovane, Giancarlo
Crispino, Vincenzo
Feola, Antonia
Medici, Nicola
Sannolo, Nicola
Di Carlo, Angelina
Di Domenico, Marina
Powiązania:
https://bibliotekanauki.pl/articles/2177165.pdf
Data publikacji:
2015-07-17
Wydawca:
Instytut Medycyny Pracy im. prof. dra Jerzego Nofera w Łodzi
Tematy:
occupational exposure
ImmunoCAP
natural rubber latex
skin prick test
contact dermatitis
gloves
Opis:
Objectives We examined the prevalence of latex allergy in subjects with occupational exposure to latex allergens for less than 5 years, determining the disease spectrum in symptomatic workers. We identified the most frequent molecular allergens by Immuno- CAP (ICAP), correlating the findings with skin prick test (SPT) results. Material and Methods Seven hundred twenty-three healthcare students using latex gloves on a regular basis were invited to participate in a baseline questionnaire screening. An ICAP serum test was performed only when a possible latex allergy was indicated by the questionnaire. Results The total number of participants responding to the baseline survey was 619. Glove-related symptoms were indicated by 4% (N = 25) of the students. The most common symptom was contact dermatitis (N = 18, 72%). In 12 subjects, ICAP revealed a real sensitization to latex, with a recombinant latex allergen profile showing a high frequency for rHev b 6.01 specific immunoglobulin E (sIgE) (N = 9, 67%). In these individuals, skin symptoms were more prevalent than other types (88%). Conclusions The combined positivity for rHev b 6.01, rHev 8 and rHev b 5 determined by ICAP identified 92% of latex-allergic subjects with short-term exposure to latex.
Źródło:
International Journal of Occupational Medicine and Environmental Health; 2015, 28, 5; 841-848
1232-1087
1896-494X
Pojawia się w:
International Journal of Occupational Medicine and Environmental Health
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Konserwanty jako istotne czynniki etiologiczne alergicznego kontaktowego zapalenia skóry
Preservatives as important etiologic factors of allergic contact dermatitis
Autorzy:
Kręcisz, Beata
Chomiczewska-Skóra, Dorota
Kieć-Świerczyńska, Marta
Powiązania:
https://bibliotekanauki.pl/articles/2165387.pdf
Data publikacji:
2015-07-02
Wydawca:
Instytut Medycyny Pracy im. prof. dra Jerzego Nofera w Łodzi
Tematy:
metyloizotiazolinon
alergiczne kontaktowe zapalenie skóry
konserwanty
testy płatkowe
zawodowe zapalenie skóry
methylisothiazolinone
allergic contact dermatitis
preservatives
patch tests
occupational dermatitis
Opis:
Wstęp Konserwanty zawarte w kosmetykach i wielu innych produktach przemysłowych mogą być przyczyną alergicznego kontaktowego zapalenia skóry. Celem pracy było określenie częstości uczulenia na wybrane konserwanty u kolejnych pacjentów Instytutu Medycyny Pracy im. prof. J. Nofera w Łodzi diagnozowanych z powodu kontaktowego zapalenia skóry oraz ustalenie, czy osoby uczulone na formaldehyd reagują jednocześnie na donory formaldehydu. Materiał i metody U 405 osób (308 kobiet, 97 mężczyzn), diagnozowanych w latach 2011–2013, przeprowadzono serię testów płatkowych z 13 środkami konserwującymi (mieszanina parabenów, formaldehyd, Quaternium 15, mieszanina chlorometyloizotiazolinon/metyloizotiazolinon, metyloizotiazolinon, metylodibromo- glutaronitryl, diazolinydylomocznik, imidazolidynylomocznik, DMDM hydantoina, 2-bromo-2-nitropropano-1,3-diol, butylokarbaminian jodopropynylu, chlorek benzalkonium, pirosiarczan sodowy – prod. Chemotechnique Diagnostics, Szwecja). Wyniki U 405 pacjentów stwierdzono 74 dodatnie wyniki testów płatkowych, w tym 52 u kobiet. Uczulenie na przynajmniej jeden z badanych konserwantów zaobserwowano u 47 osób (11,6%), w tym 34 kobiet (11%) i 13 mężczyzn (13,4%). Najczęściej uczulał metyloizotiazolinon (4,7%, w tym 5,2% kobiet, 3,1% mężczyzn), a najrzadziej parabeny, 2-bromo-2-nitropropano-1,3-diol i imidazolidynylomocznik (0,2%). Czternaście osób (3,4%), w tym 10 kobiet (3,2%) i 4 mężczyzn (4,1%), było uczulonych na formaldehyd lub/i donory formaldehydu. Aż u 11 z nich (78,6%) uczulenie miało charakter jednoważny. U 13 osób (3,2% ogółu badanych) uczulenie na konserwanty mogło mieć charakter zawodowy. Wnioski Środki konserwujące, szczególnie pochodne izotiazolinonu, są istotnymi czynnikami przyczynowymi alergicznego kontaktowego zapalenia skóry, w tym o pochodzeniu zawodowym. Osoby uczulone na formaldehyd mogą reagować jednocześnie na niektóre donory formaldehydu, ale reakcja ta zachodzi stosunkowo rzadko. Med. Pr. 2015;66(3):327–332
Background Preservatives present in cosmetics and other industrial products can cause allergic contact dermatitis. The aim of the study was to assess the frequency of allergy to selected preservatives in consecutive patients examined due to contact dermatitis in the Nofer Institute of Occupational Medicine, Łódź, and to establish whether individuals sensitized to formaldehyde react simultaneously to formaldehyde releasers. Material and Methods A group of 405 patients (308 females and 97 males) was examined in 2011–2013. In all participants patch tests with a series of 13 preservatives (paraben mix, formaldehyde, Quaternium 15, chloromethylisothiazolinone/methylisothiazolinone mix, methyldibromoglutaronitrile, diazolidinyl urea, imidazolidinyl urea, DMDM hydantoin, 2-bromo-2-nitropropane-1,3-diol, iodopropynyl butylcarbamate, benzalkonium chloride, sodium metabisulfite, produced by Chemotechnique Diagnostics, Sweden) were performed. Results Of the 405 patients 74 (including 52 females) showed positive results of patch tests. Contact allergy to at least 1 preservative was noted in 47 (11.6%) patients, including 34 (11%) females and 13 (13.4%) males. Methylisothiazolinone proved to be the most frequent sensitizer – 4.7% (5.2% females, 3.1% males) while parabens, 2-bromo-2-nitropropane-1,3-diol and imidazolidinyl urea (0.2%) were found to be the least frequent. Fourteen (3.4%) participants, 10 women and 4 men, were allergic to formaldehyde and/or formaldehyde releasers. In 11 (78.6%) of them monovalent hypersensitivity was observed. In 13 (3.2% of the examined group) patients allergy to preservatives might have been of occupational origin. Conclusions Preservatives, particularly isothiazolinones, are significant causal factors of allergic contact dermatitis, including occupational cases. Individuals sensitized to formaldehyde may react simultaneously to formaldehyde releasers, however, such reactions are relatively rare. Med Pr 2015;66(3):327–332
Źródło:
Medycyna Pracy; 2015, 66, 3; 327-332
0465-5893
2353-1339
Pojawia się w:
Medycyna Pracy
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-8 z 8

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies