Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "time distribution" wg kryterium: Temat


Wyświetlanie 1-5 z 5
Tytuł:
68Ge/68Ga radioisotope generator as a source of radiotracers for water flow investigations
Autorzy:
Palige, J.
Majkowska, A.
Herdzik, I.
Ptaszek, S.
Powiązania:
https://bibliotekanauki.pl/articles/146239.pdf
Data publikacji:
2011
Wydawca:
Instytut Chemii i Techniki Jądrowej
Tematy:
Ga-68
generator
residence time distribution (RTD)
Opis:
Radiotracer experiments on the model of rectangular settler with a volume of 3 m3, with a consecutive application as a tracer of the aqueous phase fluoresceine (representative tracer of water), eluate from a 68Ge/68Ga radioisotope generator (0.1 N HCl solution) and chelates after Ga ions complexation with 1,4,7-triazacyclononane-1,4,7-triacetic acid (NOTA) and 1,4,7,10-tetrazacyclododecane-1,4,7,10-tetraacetic acid (DOTA) were carried out. The obtained residence time distribution (RTD) functions indicate that only the complex compounds of gallium are stable in the water phase and are not adsorb on the vessel walls, so they can be recommended as tracers of the water phase.
Źródło:
Nukleonika; 2011, 56, 1; 77-80
0029-5922
1508-5791
Pojawia się w:
Nukleonika
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Radiotracer investigations of municipal sewage treatment stations
Autorzy:
Farooq, M.
Khan, I.
Ghiyas-ud-Din, Ghiyas-ud-Din
Gul, S.
Palige, J.
Dobrowolski, A.
Powiązania:
https://bibliotekanauki.pl/articles/971492.pdf
Data publikacji:
2003
Wydawca:
Instytut Chemii i Techniki Jądrowej
Tematy:
wastewater treatment
residence time distribution
activated sludge
radiotracer
Opis:
Tracer techniques, which are well-established methods in process dynamics studies in industry, were applied to investigate the dynamics of sewage treatment process. The concept of residence time distribution (RTD) was used to investigate the efficiency of the primary clarifier, aeration tank and secondary clarifier of a sewage treatment plant. Preliminary treatment and modeling of the tracer data was performed using the software DTS Pro Ver. 4.20. A big short - circuiting (by-passing) with a large volume of stagnant zones were found in the primary and secondary clarifiers, while no stagnant zone was detected in the aeration tank.
Źródło:
Nukleonika; 2003, 48, 1; 57-61
0029-5922
1508-5791
Pojawia się w:
Nukleonika
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Radioisotope tracer study in an indirectly heated rotary dryer
Autorzy:
Pant, H.
Powiązania:
https://bibliotekanauki.pl/articles/147094.pdf
Data publikacji:
2002
Wydawca:
Instytut Chemii i Techniki Jądrowej
Tematy:
holdup
lanthanum-140
mean residence time
radioisotope tracer
residence time distribution
rotary dryer
variance
Opis:
A radioisotope tracer study was carried-out in a pilot scale indirectly heated rotary dryer to measure residence time distribution (RTD) of sand particles. Lanthanum-140 labeled sand was used as a tracer. Mean residence time (MRT) and variance of the tracer distribution curves were calculated from the measured RTD curves. From the calculated MRTs, solid holdup in the dryer was estimated. The qualitative comparison of the dimensionless variance with the data published in the literature led to the conclusion that the rotary dryer behaves as a plug flow system. The results of the study were used to design a full-scale industrial rotary dryer.
Źródło:
Nukleonika; 2002, 47, 4; 173-176
0029-5922
1508-5791
Pojawia się w:
Nukleonika
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Measurement of liquid holdup and axial dispersion in trickle bed reactors using radiotracer technique
Autorzy:
Pant, H.
Saroha, A.
Nigam, K.
Powiązania:
https://bibliotekanauki.pl/articles/146732.pdf
Data publikacji:
2000
Wydawca:
Instytut Chemii i Techniki Jądrowej
Tematy:
axial dispersion model
holdup
mean residence time
Peclet number
residence time distribution
trickle-bed reactor
Opis:
The holdup and axial dispersion of aqueous phase has been measured in trickle bed reactors as a function of liquid and gas flow rates using radioisotope tracer technique. Experiments were carried out in a glass column of inner diameter 15.2´10-2 m column for air-water system using three different types of packings i.e. non-porous glass beads, porous catalysts of tablet and extrudate shape. The range of liquid and gas flow rates used were 8.3´10-5-3.3´10-4 m3/s and 0-6.67´10-4 m3/s, respectively. Residence time distributions of liquid phase were measured and mean residence times were determined. The values of liquid holdup were calculated from the measured mean residence times. It was observed that liquid holdup increased with increase in liquid flow rates and was independent of increase in gas flow rates used in the study. Two-parameter axial dispersion model was used to simulate measured residence time distribution data and values of mean residence time and Peclet number were obtained. It was observed that values of Peclet number increases with increase in liquid flow rate for glass beads and tablets and remains almost constant for extrudates. The values of mean residence time obtained from model simulation were found to be in good agreement with the values measured experimentally.
Źródło:
Nukleonika; 2000, 45, 4; 235-241
0029-5922
1508-5791
Pojawia się w:
Nukleonika
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Laser-induced ablation: physics and diagnostics of ion emission
Autorzy:
Torrisi, L.
Powiązania:
https://bibliotekanauki.pl/articles/146624.pdf
Data publikacji:
2011
Wydawca:
Instytut Chemii i Techniki Jądrowej
Tematy:
laser-generating plasma
Boltzmann distribution
time-of-flight
Opis:
Pulsed lasers generating beams of different intensities may be used to produce ablation of solid targets placed in high vacuum and to generate pulsed plasma and ion acceleration. The plasma is in a non-equilibrium condition and in the first instant the particles being generated are subject to thermal interactions, to a supersonic gas expansion in vacuum and to a Coulomb acceleration due to the high electric field developed along the normal to the target surface. The ion diagnostics, based on time-of-flight technique, allow us to measure the mean ion energy, the total number of ions, as well as the ion energy and charge state distributions. The ion energy distributions may be described by the Coulomb- -Boltzmann-Shifted (CBS) function, which after fitting to the experimental data may be used to determine the equivalent ion temperature and the accelerating voltage. Given the equivalent acceleration voltage and the plasma Debye length, it is possible to estimate the magnitude of the electric field developed in the plasma. Measurements of the ablation yield, plasma dimension and optical spectroscopy allow us to calculate the atomic and electronic plasma density and to evaluate the coronal plasma temperature. Some applications of the laser-induced ablation consist in the realization of laser ion sources (LIS), generation of multi-energetic ion beams by using a post-accelerating voltage, use of ultra-intense fs lasers to accelerate ions to energies of the order of tens MeV/nucleon. Other special applications include the pulsed laser deposition (PLD) of thin films, the laser ablation coupled to mass quadrupole spectrometry (LAMQS) probes, ablation of biological tissues, and generation of plasma for astrophysical and nuclear investigations.
Źródło:
Nukleonika; 2011, 56, 2; 113-117
0029-5922
1508-5791
Pojawia się w:
Nukleonika
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-5 z 5

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies