Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "SOURCE" wg kryterium: Temat


Tytuł:
R&D of ECR ion sources: news and perspectives
Autorzy:
Gammino, S.
Powiązania:
https://bibliotekanauki.pl/articles/148656.pdf
Data publikacji:
2003
Wydawca:
Instytut Chemii i Techniki Jądrowej
Tematy:
ion source
plasma
Opis:
The future accelerators need ion beams with higher charge state and higher current. This demand will be met by the “third generation Electron Cyclotron Resonance Ion Sources” (ECRIS) which will make use of improved plasma confinement by means of higher magnetic field and of higher microwave frequency, thus boosting the performance of nowadays ECRIS operating at the frequency of 14 and 18 GHz. The possibility to obtain confining fields exceeding 4 tesla, by means of special design of NbTi superconducting magnets, open the way to a new operational domain, at the typical frequencies of gyrotrons, above 28 GHz, with plasma densities never achieved before in ECRIS (1013 cm–3 and higher). The test of SERSE at 28 GHz, confirming the theoretical frame on which the third generation ECR sources design is based, will be presented; a synthetic review of the new generation ECRIS is carried out, with a particular emphasis on the design of the GyroSERSE source. Finally, the scheme of an innovative hybrid source will be outlined and a short description of the ECLISSE (Electron Cyclotron Resonance ion source Coupled to a Laser Ion Source for charge State Enhancement) experiment is hereinafter presented.
Źródło:
Nukleonika; 2003, 48,suppl.2; 73-79
0029-5922
1508-5791
Pojawia się w:
Nukleonika
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Recent development in ECR sources
Autorzy:
Bieth, C.
Kantas, S.
Sortais, P.
Kanjilal, D.
Rodrigues, G.
Powiązania:
https://bibliotekanauki.pl/articles/148676.pdf
Data publikacji:
2003
Wydawca:
Instytut Chemii i Techniki Jądrowej
Tematy:
ion source
ECR source
superconducting coils
high temperature superconducting wires
high charge state ion source
ion implantation
Opis:
Recent developments and improvements on the ECR ion source family at PANTECHNIK S.A. are presented. A lot of work has been done in the Ion Implantation Technology with the MICROGAN IndustryŽ source: more than 3 mA have been produced on B1+, P1+ and few hundred žAe on charge state 3+, 4+. Three other developments are described in this paper: a) the construction of the first source using high temperature superconducting coils (30 K) PKSUSŽ - Space Cryomagnetics (UK), in collaboration with NSC (New Delhi); b) the construction of the PHOENIX ECR source (used in the “1+/n+” process for radioactive beam) for different laboratories; c) and the first results on PK 2.45 (a cheap source working at 2.45 GHz) able to produce high current of monocharged beam. We will also present some special products for beam acceleration and diagnosis.
Źródło:
Nukleonika; 2003, 48,suppl.2; 93-98
0029-5922
1508-5791
Pojawia się w:
Nukleonika
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
First beam from the DECRIS 14-2m ion source for Slovak Republic
Autorzy:
Loginov, V.
Bekhterev, V.
Bogomolov, S.
Efremov, A.
Lebedev, A.
Leporis, M.
Yazvitsky, N.
Zelenak, A.
Powiązania:
https://bibliotekanauki.pl/articles/148668.pdf
Data publikacji:
2003
Wydawca:
Instytut Chemii i Techniki Jądrowej
Tematy:
ECR ion source
injector
Opis:
The ECR laboratory of the Cyclotron Centrum of Slovak Republic (CC SR) in Bratislava, Slovakia, consists of the DECRIS 14-2m ion source and two low energy channels. It is a complete injector, consisting of an ECR ion source, focusing and steering elements, an analyzing magnet, a vacuum system, and an ion beam diagnostic system. The DECRIS 14-2m ion source is a multiply charged heavy ion source based on the electron cyclotron resonance principle. The ECR ion source DECRIS 14-2m and other system have been designed and manufactured at the FLNR JINR. The preliminary testing (magnetic field measurements, vacuum testing and testing of ECR ion source) has been performed at FLNR JINR. The final assembly of the DECRIS 14-2m will be done at the CC SR in Bratislava.
Źródło:
Nukleonika; 2003, 48,suppl.2; 85-88
0029-5922
1508-5791
Pojawia się w:
Nukleonika
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
The modifications of the JYFL 6.4 GHz ECR ion source
Autorzy:
Koivisto, H.
Liukkonen, E.
Moisio, M.
Nieminen, V.
Suominen, P.
Powiązania:
https://bibliotekanauki.pl/articles/148664.pdf
Data publikacji:
2003
Wydawca:
Instytut Chemii i Techniki Jądrowej
Tematy:
ECR ion source
ion beams
Opis:
A new JYFL 14 GHz ECRIS was completed in spring 2000 for the nuclear physics program at the Department of Physics, University of Jyväskylä (JYFL). The old JYFL 6.4 GHz ECRIS (built in 1990-1991) is now also available for the material physics experiments and for the research and development work of the ECR ion sources. During the last year remarkable modifications to the structure of the source have been undertaken. In the first phase, which was completed in fall 2001, the axial magnetic field was optimized using the old power supplies and the coils. The radial magnetic field was improved in spring 2002 by installing an iron cylinder around the hexapole permanent magnets. According to the measurements the improvement of about 25% to the radial magnetic field was achieved. The research work to improve the ion beam quality has been started.
Źródło:
Nukleonika; 2003, 48,suppl.2; 81-84
0029-5922
1508-5791
Pojawia się w:
Nukleonika
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Compensated ionization chamber for (n,α) reaction measurements at a spallation neutron source
Autorzy:
Andrzejewski, J.
Yu, M.
Gledenov, M.
Korejwo, A.
Sobczak, K.
Szałański, P.
Powiązania:
https://bibliotekanauki.pl/articles/146570.pdf
Data publikacji:
2007
Wydawca:
Instytut Chemii i Techniki Jądrowej
Tematy:
ionization chamber
pulsed neutron source
Opis:
The new spallation neutron facility n_TOF (neutron time-of-flight) at CERN opens wide possibilities in measurements of neutron induced reaction cross sections. The facility with its excellent energy resolution of neutrons, low repetition rate and most important – with a very high instantaneous luminosity, makes up an extra challenge for experimenters faced by doing measurements at a high peak intensity spallation source. Our proposition is directed to the use of a compensated ionization chamber for the (n, alpha) reaction cross section measurements we plan to carry out in a wide range of neutron energy. First experience gained with using such a kind of detector at ORELA (the Oak Ridge Electron Linear Accelerator) neutron source (ORNL) was very optimistic.
Źródło:
Nukleonika; 2007, 52, 2; 51-57
0029-5922
1508-5791
Pojawia się w:
Nukleonika
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Preliminary PM2.5 and PM10 fractions source apportionment complemented by statistical accuracy determination
Autorzy:
Samek, L.
Stegowski, Z.
Furman, L.
Powiązania:
https://bibliotekanauki.pl/articles/971538.pdf
Data publikacji:
2016
Wydawca:
Instytut Chemii i Techniki Jądrowej
Tematy:
chemical analysis
particulate matter
source identification
Opis:
Samples of PM10 and PM2.5 fractions were collected between the years 2010 and 2013 at the urban area of Krakow, Poland. Numerous types of air pollution sources are present at the site; these include steel and cement industries, traffic, municipal emission sources and biomass burning. Energy dispersive X-ray fluorescence was used to determine the concentrations of the following elements: Cl, K, Ca, Ti, Mn, Fe, Ni, Cu, Zn, Br, Rb, Sr, As and Pb within the collected samples. Defi ning the elements as indicators, airborne particulate matter (APM) source profiles were prepared by applying principal component analysis (PCA), factor analysis (FA) and multiple linear regression (MLR). Four different factors identifying possible air pollution sources for both PM10 and PM2.5 fractions were attributed to municipal emissions, biomass burning, steel industry, traffic, cement and metal industry, Zn and Pb industry and secondary aerosols. The uncertainty associated with each loading was determined by a statistical simulation method that took into account the individual elemental concentrations and their corresponding uncertainties. It will be possible to identify two or more sources of air particulate matter pollution for a single factor in case it is extremely difficult to separate the sources.
Źródło:
Nukleonika; 2016, 61, 1; 75-83
0029-5922
1508-5791
Pojawia się w:
Nukleonika
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Role of a biased electrode in the production of highly charged ions using the DECRIS 14-3 ion source
Autorzy:
Leporis, M.
Bogomolov, S.
Efremov, A.
Loginov, V.
Mironov, V.
Powiązania:
https://bibliotekanauki.pl/articles/148672.pdf
Data publikacji:
2003
Wydawca:
Instytut Chemii i Techniki Jądrowej
Tematy:
ECR ion source
plasma
biased electrode
Opis:
ECR ion sources are used for the production of highly charged ions in various accelerator facilities. In most of them biased electrodes are normally used to increase the ion yield. Physical processes in the plasma of an ion source are quite complicated and the role of a biased electrode is not clear. To investigate the effect of a biased electrode on the intensity of extracted highly charged ions, an axially movable electrode was placed into the plasma chamber of the DECRIS 14-3 ion source. It was found that the intensity of Ar ions depends on the position of the biased electrode and negative bias voltage. The optimal position of the biased electrode was found near the maximum of the magnetic field. Experiments with a pulsed biased electrode were also carried out. The influence of the negative pulse on the ion yield depends on the ion charge state.
Źródło:
Nukleonika; 2003, 48,suppl.2; 89-92
0029-5922
1508-5791
Pojawia się w:
Nukleonika
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
The TSL 6.4 GHz ECR ion source – status, improvements and measurements
Autorzy:
van Rooyen, D.
Wessman, D.
Powiązania:
https://bibliotekanauki.pl/articles/148680.pdf
Data publikacji:
2003
Wydawca:
Instytut Chemii i Techniki Jądrowej
Tematy:
ion source
after-glow mode
ECR
Opis:
The TSL 6.4 GHz ECR ion source performs reliably and is well optimized for the various ion species that are routinely provided for experiments. Beam intensities are comparable with other similar sources but at the lower end of the spectrum. We are thus investigating a number of methods of improvement. The development of a micro-oven for low melting point materials was successfully concluded. Further development is needed to improve the consumption rate in order to enable more effective use of expensive isotopes. Measurements with operation of the source in the after-glow mode were successful but the pulse to pulse reproducibility should be further improved. Although the maximum gain compared to the CW mode is satisfactory, accomplishing a higher factor would be even more advantageous for beams delivered to CELSIUS. A systematic study of various parameters was started in order to find optimal operating conditions running in the after-glow mode
Źródło:
Nukleonika; 2003, 48,suppl.2; 99-104
0029-5922
1508-5791
Pojawia się w:
Nukleonika
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Operation modes of the FALCON ion source as a part of the AMS cluster tool
Autorzy:
Girka, O.
Bizyukov, A.
Bizyukov, I.
Gutkin, M.
Mishin, S.
Powiązania:
https://bibliotekanauki.pl/articles/146245.pdf
Data publikacji:
2015
Wydawca:
Instytut Chemii i Techniki Jądrowej
Tematy:
FALCON
ion source
surface wave
cluster tool
Opis:
The paper investigates the options to increase the production yield of temperature compensated surface acoustic wave (SAW) devices with a defi ned range of operational frequencies. The paper focuses on the preparation of large wafers with SiO2 and AlN/Si3N4 depositions. Stability of the intermediate SiO2 layer is achieved by combining high power density UV radiation with annealing in high humidity environment. A uniform thickness of the capping AlN layer is achieved by local high-rate etching with a focused ion beam emitted by the FALCON ion source. Operation parameters and limitations of the etching process are discussed.
Źródło:
Nukleonika; 2015, 60, 2; 327-330
0029-5922
1508-5791
Pojawia się w:
Nukleonika
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Energy transformation in Plasma Focus discharge with wire and liner as a load
Autorzy:
Kubeš, P.
Kravárik, J.
Klír, D.
Scholz, M.
Paduch, M.
Tomaszewski, K.
Karpinski, L.
Ryc, L.
Juha, L.
Krasa, J.
Szydlowski, A.
Romanova, V.
Powiązania:
https://bibliotekanauki.pl/articles/147107.pdf
Data publikacji:
2002
Wydawca:
Instytut Chemii i Techniki Jądrowej
Tematy:
plasma focus
X-ray source
XUV spectroscopy
Opis:
We present the results of experiments focused on energy transformations during the implosion of the hydrogen current sheath towards an Al wire (120 ěm in diameter) positioned on the top of the inner electrode of the PF-1000 plasma focus facility at the IPPLM in Warsaw. A wire corona is formed at the current sheath impact and ~60 ns after the impact a soft X-ray pulse is emitted. Its spectrum contains AlVI-XII lines accompanied by their satellites. The amount of emitted energy is recorded by two filtered PIN diodes and thermoluminescent dosimeters and depends on symmetry of the current sheath and quality of the current sheath focus. The mean value of energy of keV photons emitted in the runs done without the wire (~1 J) is higher than the energy obtained with the wire (~0.4 J). A time delay between the impact of the current sheath and X-ray pulse, the plasma focus dynamics and soft X-ray emission are interpreted by an axial magnetic field generation and transformations.
Źródło:
Nukleonika; 2002, 47, 4; 151-153
0029-5922
1508-5791
Pojawia się w:
Nukleonika
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Occupational exposure to Am-Be neutron calibration source mounted in OB26 shielding container
Autorzy:
Szewczak, K.
Jednorog, S.
Powiązania:
https://bibliotekanauki.pl/articles/148315.pdf
Data publikacji:
2014
Wydawca:
Instytut Chemii i Techniki Jądrowej
Tematy:
occupational exposure
active instruments measurements
neutron source calibration
Opis:
Laboratory for Dosimetric and Radon Instruments Calibration which is a part of Central Laboratory for Radiological Protection (CLRP) in Warsaw is equipped with 241Am-Be neutron calibration source with activity of 185 GBq since 1999. The capsule was mounted in the OB26 type shielding container. The control room is separated from the above source by a concrete wall of 0.5 m in thickness. The calibration hall is adjacent to one side of the offi ce room. To comply with the requirements of the radiological protection system, the occupational exposure of persons that are working both in the offi ce and control room needs to be assessed. Two methods were involved for ambient dose equivalent rate determination. The active instrument measurements (AIMs) performed with the Berthold LB6411 neutron probe and the Monte Carlo simulation method (MCS) based on MCNP5 code. These estimations were completed for fi ve reference points. Additionally the γ-radiation component was measured by RSS131 ionisation chamber. An increased value of the ambient dose equivalent rate from neutrons was observed in two reference positions. The fi rst observation was done in the control room while the second one in the offi ce room. Expected individual dose equivalents were evaluated based on the results of the AIM and on the expected working time in particular reference points. The annual individual dose equivalent associated with calibration activities using mentioned neutron source was estimated at maximum 0.8 mSv.
Źródło:
Nukleonika; 2014, 59, 3; 97-103
0029-5922
1508-5791
Pojawia się w:
Nukleonika
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Mechanical design of the gamma blockers for the high-energy beam transport region of the European Spallation Source
Autorzy:
Wojciechowski, Marcin
Szymczyk, Karol
Wronka, Sławomir
Powiązania:
https://bibliotekanauki.pl/articles/24202754.pdf
Data publikacji:
2023
Wydawca:
Instytut Chemii i Techniki Jądrowej
Tematy:
European Spallation Source
ESS
gamma blocker
gamma radiation
Opis:
The European Spallation Source (ESS) is a collaboration of 13 European countries to build the world’s most powerful neutron source for research. The project, situated in the south of Sweden, is approaching the end of the construction phase, and the fi rst scientifi c results are planned for 2023. This paper gives an overview of mechanical design of the gamma blockers (GBs) in the accelerator to target (A2T) and dump line (DmpL) sections. The presence of GBs in the beam line should limit the gamma radiation emitted from the activated tungsten target and beam dump to allow the safe access of the staff to the machine. The presented design allows for effi cient operation and the same shutting time independently of the vacuum status.
Źródło:
Nukleonika; 2023, 68, 3; 77--80
0029-5922
1508-5791
Pojawia się w:
Nukleonika
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Stabilizing of Z-pinch and Plasma Focus discharges due to thick wires
Autorzy:
Kubeš, P.
Kravárik, J.
Paduch, M.
Tomaszewski, K.
Scholz, M.
Karpinski, L.
Szydlowski, A.
Bakshaev, Y.
Blinov, P.
Chernenko, A. S.
Gordeev, E. M.
Dan’ko, S. A.
Korolev, V. D.
Shashkov, A.
Tumanov, V. I.
Romanova, V.
Klír, D.
Powiązania:
https://bibliotekanauki.pl/articles/146991.pdf
Data publikacji:
2001
Wydawca:
Instytut Chemii i Techniki Jądrowej
Tematy:
plasma focus
X-ray source
XUV spectroscopy
Z-pinch
Opis:
This paper presents the results of the diagnostics observing the impact of the plasma sheath imploded in megaamper Z-pinch or plasma focus devices onto the Al or C wires of 30-300 mi m in diameter fixed in the center axis. The discharges were operated with a maximum current of 1.5-3 MA at two devices, PF 1000 at IPFLM in Warsaw, and Stand 300 at RRC Kurchatov Institute in Moscow. At the plasma impact the 10-50 ns XUV pulse was emitted in K-shell lines from the ring or helical-like forms on the surface of the wire corona. The scenario of the production of the non-equilibrium intensities of the C and Al H-like and He-like lines is discussed considering fast transformation of magnetic field, electron beams acceleration, total ionization of the ions and fast recombination in dense and magnetized wire corona.
Źródło:
Nukleonika; 2001, 46, 1; 5-7
0029-5922
1508-5791
Pojawia się w:
Nukleonika
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Pinch modes in the SPEED2 plasma focus
Autorzy:
Kies, W.
Decker, G.
Berntien, U.
Sidelnikov, U.
Glushkov, D.
Koshelev, K.
Simanovskij, D.
Bobashev, S.
Powiązania:
https://bibliotekanauki.pl/articles/146993.pdf
Data publikacji:
2001
Wydawca:
Instytut Chemii i Techniki Jądrowej
Tematy:
pinch plasma
pinch stability
plasma focus
plasma radiation
radiation source
Opis:
Deuterium discharges in the SPEED2 plasma focus (80 kJ, 200 kV, 2 MA, 400 ns) have been found unexpectedly stable within the operational regime as a neutron source. Only at higher filling pressures (above 6 mbar) sometimes m=0 instabilities appeared in the pinch column, especially in discharges of lower efficiency (moderate dynamics and neutron yield). Enhancing the electromagnetic radiation by doping these discharges with heavy gases (e.g. neon, argon) distinctly two pinch modes are produced, the micropinch mode (MPM) or the stable column mode (SCM), with a transition regime where the initial SCM is followed by the MPM. Micropinches are local radiative collapses initiated by m=0 instabilities of low-energy- density pinch plasmas. These instabilities and the successive micropinches can be suppressed by kinetic deuterons produced during dynamical compression of high-energy-density deuterium plasma sheaths. Depending on the relaxation of this fast deuteron component the pinch column can be stabilized for several tens of nanoseconds. While the short-lived (appr. 1 ns) micropinches erratically appear as point-like successive flashes along the pinch axis with temperatures about 1 keV and about solid density the reproducible SCM, optimized with respect to the compression ratio, forms a powerful linear radiation source of temperatures and densities similar to the MPM. The SCM needs powerful (fast) drivers in order to use the kinetic ion stabilization, but not necessarily MA currents as available from the SPEED2 driver. This opens the possibility to establish the SCM also in compact experiments like SPEED3 (8 kJ, 80 kV, 0.8 MA, 300 ns) or even SPEED4 (2 kJ, 40 kV, 250 kA, 300 ns).
Źródło:
Nukleonika; 2001, 46, 1; 9-14
0029-5922
1508-5791
Pojawia się w:
Nukleonika
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Production of actinium-225 from a (n,p) reaction: Feasibility and pre-design studies
Autorzy:
Abolaban, Fouad A.
Banoqitah, Essam M.
Taha, Eslam M.
Alhawsawi, Abdulsalam M.
Djouider, Fathi A.
Nisbet, Andrew
Powiązania:
https://bibliotekanauki.pl/articles/2055664.pdf
Data publikacji:
2021
Wydawca:
Instytut Chemii i Techniki Jądrowej
Tematy:
Actinium-225
radiopharmaceutical
Californium-252
neutron source
(n,p) reaction
Opis:
Actinium-225 is used in nuclear medicine for the treatment of malignant tumours. It can be applied to produce Bi-213 in a reusable generator or can be used alone as an agent for radiation therapy, in particular for targeted alpha therapy. However, the availability of Ac-225 for worldwide use, particularly in low- and middle-income countries, is limited. We present a feasibility study employing GATE, an open-source Monte Carlo simulation toolkit, on the production of Ac-225 from a neutron generator. This work suggests that a design consisting of three concentric cylinders, the innermost a Cf-252 neutron source, the middle nickel cylinder acting as a proton-producing target and the outer cylinder a RaCl2 target may provide a feasible design outline for an Ac-225 generator.
Źródło:
Nukleonika; 2021, 66, 2; 61--67
0029-5922
1508-5791
Pojawia się w:
Nukleonika
Dostawca treści:
Biblioteka Nauki
Artykuł

Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies