Tytuł:
Energy composition of high-energy neutral beams on the COMPASS tokamak
Autorzy:
Mitosinkova, A.
Stöckel, J.
Varju, J.
Weinzettl, V.
Powiązania:
https://bibliotekanauki.pl/articles/147959.pdf
Data publikacji:
2016
Wydawca:
Instytut Chemii i Techniki Jądrowej
Tematy:
tokamak
neutral beam injection (NBI)
Doppler effect
beam composition
beamlet divergence
Opis:
The COMPASS tokamak is equipped with two identical neutral beam injectors (NBI) for additional plasma heating. They provide a beam of deuterium atoms with a power of up to ~(2 × 300) kW. We show that the neutral beam is not monoenergetic but contains several energy components. An accurate knowledge of the neutral beam power in each individual energy component is essential for a detailed description of the beam- -plasma interaction and better understanding of the NBI heating processes in the COMPASS tokamak. This paper describes the determination of individual energy components in the neutral beam from intensities of the Doppler-shifted Dα lines, which are measured by a high-resolution spectrometer viewing the neutral beam-line at the exit of NBI. Furthermore, the divergence of beamlets escaping single aperture of the last accelerating grid is deduced from the width of the Doppler-shifted lines. Recently, one of the NBI systems was modifi ed by the removal of the Faraday copper shield from the ion source. The comparison of the beam composition and the beamlet divergence before and after this modifi cation is also presented.
Źródło:
Nukleonika; 2016, 61, 4; 419-423
0029-5922
1508-5791
Pojawia się w:
Nukleonika
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Calculation of edge ion temperature and poloidal rotation velocity from carbon III triplet measurements on the COMPASS tokamak
Autorzy:
Tomeš, M.
Weinzettl, V.
Pereira, T.
Imríšek, M.
Seidl, J.
Powiązania:
https://bibliotekanauki.pl/articles/148182.pdf
Data publikacji:
2016
Wydawca:
Instytut Chemii i Techniki Jądrowej
Tematy:
high-resolution spectroscopy
spectra processing
peak detection
line detection
line fitting
poloidal plasma rotation
ion temperature
Opis:
A high-resolution spectroscopic system for the measurements of the CIII triplet at 465 nm was installed at the COMPASS tokamak. The Doppler broadening and shift of the measured spectral lines are used to calculate the edge ion temperature and poloidal plasma rotation. At first, the spectroscopic system based on two-grating spectrometer and the calibration procedure is described. The signal processing including detection and removal of spiky features in the signal caused by hard X-rays based on the difference in the behaviour of Savitzky-Golay and median filters is explained. The detection and position estimation of individual spectral lines based on the continuous wavelet transform is shown. The method of fitting of Gaussians using the orthogonal distance regression and estimation of the error of estimation of the rotation velocity and ion temperature is described. At the end, conclusions about the performance of the spectroscopic system and its shortcomings based on summary of results calculated from 2033 processed spectral lines measured in 61 shots are drawn and the possible enhancements are suggested.
Źródło:
Nukleonika; 2016, 61, 4; 443-451
0029-5922
1508-5791
Pojawia się w:
Nukleonika
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Optimization of soft X-ray tomography on the COMPASS tokamak
Autorzy:
Imríšek, M.
Mlynář, J.
Löffelmann, V.
Weinzettl, V.
Odstrčil, T.
Odstrčil, M.
Tomeš, M.
Powiązania:
https://bibliotekanauki.pl/articles/146251.pdf
Data publikacji:
2016
Wydawca:
Instytut Chemii i Techniki Jądrowej
Tematy:
soft X-ray
tomography
Tikhonov regularization
tokamak
Opis:
The COMPASS tokamak is equipped with the soft X-ray (SXR) diagnostic system based on silicon photodiode arrays shielded by a thin beryllium foil. The diagnostic is composed of two pinhole cameras having 35 channels each and one vertical pinhole camera with 20 channels, which was installed recently to improve tomographic inversions. Lines of sight of the SXR detectors cover almost complete poloidal cross section of the COMPASS vessel with a spatial resolution of 1–2 cm and temporal resolution of about 3 s. Local emissivity is reconstructed via Tikhonov regularization constrained by minimum Fisher information that provides reliable and robust solution despite limited number of projections and ill-conditionality of this task. Improved border conditions and numerical differentiation matrices suppressing artifacts in reconstructed radiation were implemented in the code. Furthermore, a fast algorithm eliminating iterative processes was developed, and it is foreseen to be tested in real-time plasma control.
Źródło:
Nukleonika; 2016, 61, 4; 403-408
0029-5922
1508-5791
Pojawia się w:
Nukleonika
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
First dedicated observations of runaway electrons in the COMPASS tokama
Autorzy:
Vlainić, M.
Mlynář, J.
Weinzettl, V.
Papřok, R.
Imríšek, M.
Ficker, O.
Vondráček, P.
Havlíček, J.
Powiązania:
https://bibliotekanauki.pl/articles/971514.pdf
Data publikacji:
2015
Wydawca:
Instytut Chemii i Techniki Jądrowej
Tematy:
plasma diagnostics
runaway electrons
tokamak
Opis:
Runaway electrons present an important part of the present efforts in nuclear fusion research with respect to the potential damage of the in-vessel components. The COMPASS tokamak a suitable tool for the studies of runaway electrons, due to its relatively low vacuum safety constraints, high experimental flexibility and the possibility of reaching the H-mode D-shaped plasmas. In this work, results from the first experimental COMPASS campaign dedicated to runaway electrons are presented and discussed in preliminary way. In particular, the first observation of synchrotron radiation and rather interesting raw magnetic data are shown.
Źródło:
Nukleonika; 2015, 60, 2; 249-255
0029-5922
1508-5791
Pojawia się w:
Nukleonika
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-4 z 4

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies