Tytuł:
The influence of air conditioning changes on the effective dose due to radon and its short-lived decay products
Autorzy:
Grządziel, A.
Kozak, K.
Mazur, J.
Połednik, B.
Dudzińska, M. R.
Bilska, I.
Powiązania:
https://bibliotekanauki.pl/articles/147303.pdf
Data publikacji:
2016
Wydawca:
Instytut Chemii i Techniki Jądrowej
Tematy:
radon
radon progeny
attached fraction of radon progeny
unattached fraction of radon progeny
dose conversion factor
Opis:
Most people spend the majority of their time in indoor environments where the level of harmful pollutants is often significantly higher than outdoors. Radon (222Rn) and its decay products are the example of radioactive pollutants. These radioisotopes are the main source of ionizing radiation in non-industrial buildings. The aim of the study was to determine the impact of air-conditioning system on radon and its progeny concentrations and thus on the effective dose. The measurements were carried out in the auditorium at the Environmental Engineering Faculty (Lublin University of Technology, Poland). Measurements of radon and its progeny (in attached and unattached fractions) as well as measurements of the following indoor air parameters were performed in two air-conditioning (AC) operation modes: AC ON and AC ON/OFF. The air supply rate and air recirculation were taken into consideration. The separation of radon progeny into attached and unattached fractions allowed for determining, respectively, the dose conversion factor (DCF) and the inhalation dose for teachers and students in the auditorium. A considerable increase of the mean radon progeny concentrations from 1.2 Bq/m3 to 5.0 Bq/m3 was observed in the AC ON/OFF mode compared to the AC ON mode. This also resulted in the increase of the inhalation dose from 0.005 mSv/y to 0.016 mSv/y (for 200 h/year). Furthermore, the change of the air recirculation rate from 0% to 80% resulted in a decrease of the mean radon concentration from 30 Bq/m3 to 12 Bq/m3 and the reduction of the mean radon progeny concentration from 1.4 Bq/m3 to 0.8 Bq/m3. This resulted in the reduction of the inhalation dose from 0.006 mSv/y to 0.003 mSv/y.
Źródło:
Nukleonika; 2016, 61, 3; 239-244
0029-5922
1508-5791
Pojawia się w:
Nukleonika
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Intercomparison of radon CR-39 detector systems conducted in CLORs calibration chamber
Autorzy:
Mamont-Cieśla, K.
Stawarz, O.
Karpińska, M.
Kapała, J.
Kozak, K.
Grządziel, D.
Chałupnik, S.
Chmielewska, I.
Olszewski, J.
Przylibski, T. A.
Żebrowski, A.
Powiązania:
https://bibliotekanauki.pl/articles/148842.pdf
Data publikacji:
2010
Wydawca:
Instytut Chemii i Techniki Jądrowej
Tematy:
radon-222
CR-39 track detector
intercomparison
RadoSys
Opis:
Six radon laboratories, which perform indoor radon measurements to jointly investigate temporal variations of radon concentration in houses in a couple of regions in Poland, participated in the intercomparison exercise. There are involved three commercially available Hungarian RadoSys systems and four own laboratory methods. All of them are based on the etched-track CR-39 detectors. The intercomparison was conducted in a calibration laboratory of the Central Laboratory for Radiological Protection (CLOR), Warsaw, Poland, accredited by the Polish Center for Accreditation (previously AP 101, at present AP 057). Comparison measurements were performed during three expositions in the CLOR’s radon calibration chamber under controlled normal climatic conditions and steady radon concentration. The results were referred to the value of the radon concentration determined by AlphaGUARD monitor traceable to the primary 222Rn standard in Physikalisch-Technische Bundesanstalt (PTB), Braunchweig, Germany. The mean performance ratio defined as a ratio of the reference to participant’s result range from 0.88 to 1.31.
Źródło:
Nukleonika; 2010, 55, 4; 589-593
0029-5922
1508-5791
Pojawia się w:
Nukleonika
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Preliminary results of radon survey in thermal spas in V4 countries
Autorzy:
Műllerová, M.
Mazur, J.
Blahušiak, P.
Grządziel, D.
Holý, K.
Kovács, T.
Kozak, K.
Nagy, E.
Neznal, M.
Shahrokhi, A.
Powiązania:
https://bibliotekanauki.pl/articles/146825.pdf
Data publikacji:
2016
Wydawca:
Instytut Chemii i Techniki Jądrowej
Tematy:
indoor radon
thermal spas
thermal water
Opis:
Radon concentration was measured in 11 thermal spas in Visegrad countries (Czech Republic, Hungary, Poland, and Slovakia). The results showed that in 84% of spas radon activity concentration is less than 400 Bq·m–3. However, areas with radon activity concentration exceeding 1000 Bq·m–3 were found in the Czech Republic and Slovakia as well. Preliminary analyses indicated that the highest radon activities in spas were found in places with thermal pools. Radon concentration in waters used in spas ranged from 0.5 Bq/l to 384 Bq/l. The influence of radon activity concentration in water on radon activity in the air inside the spa was observed. It was found to increase indoor radon with increasing radon in the waters. Correlation with indoor radon and radon in water was more significant for baths and less significant for pool waters. In the cases filling of the bath from water taps, significantly contribute to the increased radon was observed in the pool and bath areas of the spa.
Źródło:
Nukleonika; 2016, 61, 3; 303-306
0029-5922
1508-5791
Pojawia się w:
Nukleonika
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-3 z 3

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies