Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "kindergartens" wg kryterium: Wszystkie pola


Wyświetlanie 1-2 z 2
Tytuł:
Slovenian approach in managing exposure to radon at workplaces
Autorzy:
Vaupotič, J.
Powiązania:
https://bibliotekanauki.pl/articles/148828.pdf
Data publikacji:
2010
Wydawca:
Instytut Chemii i Techniki Jądrowej
Tematy:
radon
kindergartens
schools
wineries
spas
water plants
hospitals
karst caves
mitigation
Opis:
Radon was surveyed in all the kindergartens and schools, major hospitals, water plants, wineries, spas, in a number of other public buildings, and karst caves with emphasis on the Postojna Cave (Slovenia). In addition to radon, also the concentration of radon short-lived decay products, equilibrium factor between radon and decay products, and unattached fraction of decay products have been monitored. Effective doses were calculated and used as a criterion to require remediation.
Źródło:
Nukleonika; 2010, 55, 4; 565-571
0029-5922
1508-5791
Pojawia się w:
Nukleonika
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Radon exposure in kindergartens in one Bulgarian district
Autorzy:
Angelova, Antoaneta
Chobanova, Nina
Kunovska, Bistra
Djunakova, Desislava
Ivanova, Kremena
Stojanovska, Zdenka
Powiązania:
https://bibliotekanauki.pl/articles/24202747.pdf
Data publikacji:
2023
Wydawca:
Instytut Chemii i Techniki Jądrowej
Tematy:
Bulgaria
effective dose
kindergarten
passive detector
radon concentration
Opis:
The major part of the radiation dose that humans receive from natural radioactive sources is due to inhalation of radon and its decay products. The study focuses on radon concentration (CRn) investigation in kindergartens and nurseries in the district of Montana. The infl uence of building characteristics on CRn was evaluated. The measurement of the CRn was performed using passive detectors. The survey was carried out between December 2019 and May 2020 with a total number of 602 detectors. The average value of CRn in the premises of the studied kindergartens and nurseries in this district is 125 Bq·m−3 , and the geometric mean (GM) value is 88 Bq·m−3 . The buildings that have built ventilation and sewerage systems have lower CRn. The effective doses of the children and workers were evaluated in order to assess the radon exposure.
Źródło:
Nukleonika; 2023, 68, 2; 51--56
0029-5922
1508-5791
Pojawia się w:
Nukleonika
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-2 z 2

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies