Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "Owczarek, Mariusz" wg kryterium: Wszystkie pola


Wyświetlanie 1-4 z 4
Tytuł:
An experimental method for estimating the thermal diffusivity of building elements, depending on the resolution of temperature measurement
Autorzy:
Owczarek, Mariusz
Powiązania:
https://bibliotekanauki.pl/articles/132057.pdf
Data publikacji:
2019
Wydawca:
Centrum Rzeczoznawstwa Budowlanego Sp. z o.o.
Tematy:
thermal diffusivity
physical properties
Opis:
Thermal diffusivity, also known as temperature equalization coefficient, is the basic parameter in the Fourier equation for non-stationary heat exchange. Its values are known for homogeneous materials with a specific composition. Building elements made of reinforced concrete, for example, have a heterogeneous structure. For such cases, table values from the literature may differ significantly from the specific object for in real constructions. More accurate thermal diffusivity values can be obtained from measurements for a given element. Since these are usually large sized elements, the measurement method should take into account the material in the entire volume of the element. Proposals for such a method based solely on temperature measurement at several depths in the sample were presented. It consists in solving the inverse problem assuming a polynomial solution of the Fourier equation. An attempt was made to validate the method through a numerical experiment. Temperature variability was simulated with one-dimensional flow in the wall with assumed thermal diffusivity. Then the value of this diffusivity was determined from the calculated temperatures. On the inside of the partition, a constant temperature was maintained and on the outside it changed periodically. The dependence of the error in the obtained diffusivity value on the precision of temperature results was analyzed. Depending on the precision of the calculations, a minimum relative error of 2 to 6 percent was obtained. With the help of the data presented in the article, conclusions can be drawn as to the conditions that must be met to determine the value of diffusivity in real measurements with the required accuracy. The obtained results indicate that this method is worth further research.
Źródło:
Modern Engineering; 2019, 1; 28-33
2450-5501
Pojawia się w:
Modern Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Hybrydowe układy ogrzewania
Autorzy:
Gawryś, Daniel
Owczarek, Mariusz
Powiązania:
https://bibliotekanauki.pl/articles/111019.pdf
Data publikacji:
2019
Wydawca:
Centrum Rzeczoznawstwa Budowlanego Sp. z o.o.
Tematy:
hybrydowy system ogrzewania
pompy ciepła
kolektory słoneczne
węzły cieplne
hybrid heating system
heat pumps
solar collectors
heat centre
Opis:
Wybór najlepszego rozwiązania ma na celu zbadanie ekonomiczności rozwiązań dla hybrydowych układów ogrzewania oraz wybór według kryterium najniższego kosztu. Poddany analizie budynek jest biurowym obiektem budowlanym o fasadzie szklanej. Przyjęte zostały dwa układy hybrydowe. Pierwszy z nich zakłada pompę ciepła oraz węzeł cieplny do spełnienia całego zapotrzebowania na ciepło. Drugi układ przewiduje zastosowanie pompy ciepła oraz węzła cieplnego do ogrzania budynku oraz kolektory słoneczne do zapewnienia ciepłej wody użytkowej.
Choosing the best solution is to examine the cost-effectiveness of hybrid heating systems and the choice one of the criterion of the lowest cost. Analyzed building is an office building structure with a glass facade. We adopted two hybrid systems. The first of these involves the heating pump and the substation to meet total demand for heat. The second system provides for the use of heat pumps and district heating to heat the building and solar panels to deliver hot water.
Źródło:
Inżynieria Bezpieczeństwa Obiektów Antropogenicznych; 2019, 1-2; 1-7
2450-1859
2450-8721
Pojawia się w:
Inżynieria Bezpieczeństwa Obiektów Antropogenicznych
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Analytical model of wetting the porous medium
Autorzy:
Owczarek, Stefan
Owczarek, Mariusz
Gawryś, Daniel
Powiązania:
https://bibliotekanauki.pl/articles/111129.pdf
Data publikacji:
2020
Wydawca:
Centrum Rzeczoznawstwa Budowlanego Sp. z o.o.
Tematy:
humidity in porous materials
heat transfer coefficient
moisturizing
wilgotność w materiałach porowatych
współczynnik przewodzenia ciepła
nawilżanie
Opis:
The purpose of this article is to develop an analytical model for determining the weakening of the thermal insulation capacity of porous materials - mineral wool and polystyrene because of increased water content. In the dry state, it was assumed that the sample consists of a skeleton and air-filled pores without process moisture content. In the second shot, however, dry material skeleton and pores with dry air and moisture content were taken into account. In addition, the results of tests involving the process of absorbing moisture in different moisturizing environments for both types of materials were presented. Based on the adopted calculation model, the value of the heat conduction coefficient in the dry state was determined based on the sum of the products of the volume shares of individual components of the material sample, i.e. the apparent volume of the sample material skeleton and the volume of air pores contained. The results of the thermal conductivity coefficient λ obtained in this way are consistent with those obtained from measurements during the experiment. This allowed to determine the validation of the adopted calculation model.
Celem tego artykułu jest opracowanie modelu analitycznego do określania osłabienia zdolności izolacji termicznej materiałów porowatych - wełny mineralnej i polistyrenu z powodu zwiększonej zawartości wody. W stanie suchym przyjęto, że próbka składa się ze szkieletu i wypełnionych powietrzem porów bez zawartości wilgoci procesowej. W stanie wilgotnym wzięto pod uwagę szkielet i pory suchego materiału z zawartością suchego powietrza i wilgoci. Ponadto przedstawiono wyniki badań procesu absorpcji wilgoci w różnych środowiskach nawilżających dla obu rodzajów materiałów. Na podstawie przyjętego modelu obliczeniowego wartość współczynnika przewodzenia ciepła w stanie suchym została ustalona na podstawie sumy iloczynów udziałów objętościowych poszczególnych składników próbki materiału, tj. szkieletu i porów. Uzyskane w ten sposób wyniki współczynnika przewodzenia ciepła λ są zgodne z wynikami uzyskanymi z pomiarów podczas eksperymentu. Umożliwiło to weryfikację poprawności przyjętego modelu obliczeniowego.
Źródło:
Inżynieria Bezpieczeństwa Obiektów Antropogenicznych; 2020, 1; 1-18
2450-1859
2450-8721
Pojawia się w:
Inżynieria Bezpieczeństwa Obiektów Antropogenicznych
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Application of thermal insulating plaster for retrofitting of a building under conservation protection
Autorzy:
Owczarek, Mariusz
Sadowska, Beata
Kuczerowski, Michał Jakub
Baryłka, Adam
Powiązania:
https://bibliotekanauki.pl/articles/24201296.pdf
Data publikacji:
2023
Wydawca:
Centrum Rzeczoznawstwa Budowlanego Sp. z o.o.
Tematy:
measurements of insulation material properties
retrofitting
thermal insulation plaster
conservation protection
energy efficiency improvement
tynk termoizolacyjny
modernizacja
poprawa efektywności energetycznej
pomiar właściwości materiałów izolacyjnych
ochrona konserwatorska
Opis:
The article presents the results of measurements of selected thermal, moisture and mechanical properties of thermal insulating plaster, which is one of the alternatives to traditional methods of retrofitting the walls of buildings under conservation protection. An insulating plaster based on perlite was tested. Its thermal conductivity, vapor permeability and compression strength were determined. Images of the tested plaster under the microscope, at a magnification of 10-45x, were also taken. Through computer simulations, the possibility of improving the energy efficiency of an educational building by applying a layer of such plaster on external walls was determined. Changes in the heat loss structure were analyzed, and the obtained results were compared with the effectiveness of reducing heat loss through the walls using a traditional thermal insulation material. It turned out that the thermal conductivity coefficient of the tested plaster obtained by measurement was 0.0877 W/(m∙K), which confirmed the value declared by the manufacturer. Application of thermal insulating plaster with a thickness of 5 cm on the walls of the analyzed building, with other partitions of good thermal quality, reduced its energy demand by over 20%.
Źródło:
Inżynieria Bezpieczeństwa Obiektów Antropogenicznych; 2023, 2; 17--25
2450-1859
2450-8721
Pojawia się w:
Inżynieria Bezpieczeństwa Obiektów Antropogenicznych
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-4 z 4

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies