Wyszukujesz frazę "false" wg kryterium: Temat


Wyświetlanie 1-5 z 5
Tytuł:
Reducing the Multi-Sensor Smoke Detectors Susceptibility to False Triggering
Ograniczenie podatności wielodetektorowych czujek pożarowych na mylne wzbudzenia
Autorzy:
Szafarczyk, Kalina
Powiązania:
https://bibliotekanauki.pl/articles/34670981.pdf
Data publikacji:
2022
Wydawca:
Centrum Naukowo-Badawcze Ochrony Przeciwpożarowej im. Józefa Tuliszkowskiego
Tematy:
fire detector
false alarms
detector operating modes
reduction of false triggering of fire detectors
czujka pożarowa
fałszywe alarmy
tryby pracy czujki
ograniczenie mylnych wzbudzeń czujek pożarowych
Opis:
Purpose: An assessment of the possibility of reducing the susceptibility of fire detectors to false alarms was carried out by: 1) analysing the impact of changing the operating modes of a multi-sensor detector on minimizing false alarms, and 2) verifying, using ANOVA tests, two hypotheses: either the settings or the sensitivity of the sensor affect the susceptibility of the detectors to false alarms. Project and methods: In order to assess the impact of false alarms on the operation of facilities equipped with a Fire Alarm System, a survey was conducted, directed at their administrators. A study of the fire detectors susceptibility to false alarms included placing the DTC-6046 multi-sensor detector in a closed test chamber and initiating the detector’s triggering by a deceptive agent. It was then observed whether the detector would initiate a fire alarm depending on different operating mode settings. The operation of the sensors was changed to interdependent, independent or coincidence work. Sensitivity settings of the sensors were changed from normal to increased by 20%, decreased by 20% or by 40%. An analysis using ANOVA test was conducted to verify which settings have a significant impact on minimising false alarms. Based on the results, example configuration guidelines were developed. Results: Based on the study, the following main results were formulated. The configuration least prone to false triggering is the one in which the sensors operate interdependently and the sensitivity is reduced by 40%. The highest number of false alarms was observed when sensitivity was increased by 20% with independent sensors and in coincidence, as well as for independent sensors working at normal sensitivity. Performing verification using ANOVA analysis of variance, the hypothesis that sensor settings have a statistically significant effect on minimising false alarms was rejected. Conclusions: There is a need to search for and implement ways to minimise false alarms of Fire Alarm Systems. The most common reason for false triggering of fire detectors are external factors that are not fire hazards (e.g. dust, dirt). The way of minimising false alarms is a proper setting of the detector operating modes (not often used in practice). The operating modes are based on changing the settings of sensor cooperation and detector sensitivity, where changing only the settings of the sensors does not result in such significant changes as changing the sensitivity of the detectors to increased or decreased compared to normal (result of ANOVA analysis).
Cel: Ocena możliwości ograniczania podatności czujek pożarowych na mylne wzbudzenia wykonana na podstawie: 1) analizy wpływu zmiany trybów pracy czujki wielodetektorowej na minimalizację fałszywych alarmów oraz 2) weryfikacji przy wykorzystaniu testów ANOVA dwóch hipotez: nastawy albo czułość sensorów wpływają na podatność czujek na mylne wzbudzenia. Projekt i metody: Aby ocenić wpływ fałszywych alarmów na funkcjonowanie obiektów, przeprowadzono ankietę, skierowaną do administratorów obiektów wyposażonych w system sygnalizacji pożarowej. Badania laboratoryjne podatności czujek pożarowych na mylne wzbudzenia polegały na umieszczeniu czujki wielodetektorowej DTC-6046 w zamkniętej komorze badawczej i próbie wzbudzenia jej czynnikiem zwodniczym. Obserwowano, czy czujka zainicjuje alarm pożarowy w zależności od różnych ustawień trybów pracy. Zmieniane były parametry określające pracę sensorów (współzależnie, niezależnie, w koincydencji) oraz ustawienia ich czułości z normalnej na podwyższoną o 20%, obniżoną o 20% bądź 40%. Przebadano 12 konfiguracji. Wyniki poddano analizie statystycznej metodą ANOVA, która pozwoliła na weryfikację, które ustawienia wpływają znacząco na minimalizację fałszywych alarmów. Na tej podstawie opracowane zostały przykładowe wytyczne konfiguracji. Wyniki: Na podstawie przeprowadzonych badań sformułowano poniższe główne ich wyniki. Najmniej podatna na fałszywe zadziałania jest konfiguracja, w której sensory działają współzależnie, a czułość jest obniżona o 40%. Najwyższą liczbą fałszywych alarmów charakteryzują się ustawienia czułości podwyższonej o 20% w przypadku sensorów niezależnych oraz będących w koincydencji, jak i dla sensorów niezależnych zadziałanie przy czułości normalnej. Przeprowadzenie weryfikacji, wykorzystując analizę wariancji ANOVA, pozwoliło odrzucić hipotezę, jakoby nastawy sensorów w istotnie statystyczny sposób wpływały na minimalizację fałszywych alarmów. Wnioski: Występuje konieczność poszukiwania i wdrażania sposobów minimalizowania fałszywych alarmów SSP. Najczęstszym powodem mylnego wzbudzania czujek pożarowych są czynniki zewnętrzne, niebędące zagrożeniem pożarowym (np. pył, kurz). Sposobem na ograniczenie tego zjawiska jest właściwe ustawienie trybów pracy czujki (stosowane w praktyce niezbyt często). Tryby pracy opierają się na zmianie ustawień współpracy sensorów oraz czułości czujki, gdzie zmiana tylko ustawień sensorów nie powoduje tak znaczących zmian, jak zmiana czułości czujek na podwyższoną bądź obniżoną w stosunku do normalnej (wynik analizy ANOVA).
Źródło:
Safety and Fire Technology; 2022, 60, 2; 164-174
2657-8808
2658-0810
Pojawia się w:
Safety and Fire Technology
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Wpływ pyłów pochodzenia drzewnego na działanie czujek pożarowych dymu
Influence of Wooden-Based Dusts on Smoke Fire Detectors
Autorzy:
Wnęk, W.
Jargieło, M.
Porowski, R.
Powiązania:
https://bibliotekanauki.pl/articles/373369.pdf
Data publikacji:
2016
Wydawca:
Centrum Naukowo-Badawcze Ochrony Przeciwpożarowej im. Józefa Tuliszkowskiego
Tematy:
systemy sygnalizacji pożarowej
czujki dymu
fałszywe alarmy
pył drzewny
fire detection systems
smoke detectors
false alarms
wooden dust
Opis:
Cel: Obecnie poszukuje się rozwiązań w zakresie czujek pożarowych dymu, które nie będą wrażliwe na sygnały zwodnicze powodujące fałszywe alarmy pożarowe central sygnalizacji pożarowej. Jednym z takich sygnałów jest występujący w pomieszczeniach pył drzewny traktowany przez czujkę jako dym o dużych cząstkach. W artykule opisano wykonane badania wybranych czujek dymu dla różnych pyłów drzewnych. Celem podstawowym artykułu jest wybór najbardziej odpornej czujki dymu na cząstki pyłu, bez pogorszenia jej właściwości detekcyjnych. Wprowadzenie: Podczas projektowania instalacji systemów sygnalizacji pożarowej napotyka się na problemy doboru czujek pożarowych pracujących w otoczeniu różnych zakłóceń powodujących fałszywe alarmy. Początkowo zbadano wpływ pyłu celulozowego wytwarzanego przy produkcji czasopism w jednej z drukarni. Następnie przeanalizowano również wpływ innych pyłów. Przy pomiarach mieszaniny cząstek o różnych wielkościach nie można jednoznacznie ocenić ich wpływu na sposób wykrywania. W związku z tym dokonano podziału pyłu ze względu na wielkość jego cząstek na pył o średnicach 100 μm, 200 μm i 500 μm. Pozwoliło to na zbadanie wpływu nie tylko rodzaju drewna, ale także wielkości cząstek pyłu na zadziałanie czujek. Metodologia: W trakcie badań opracowano metodę pomiaru wpływu pyłu na zadziałanie czujek. Dobrano ciśnienie sprężonego powietrza na poziomie 1,5 bar wraz z czasem otwarcia zaworu butli ze sprężonym powietrzem tak, aby osiągnąć najlepsze rozprowadzenie pyłu w pomieszczeniu badawczym. Za krótki czas otwarcia zaworu powodował pozostawanie pyłu w pojemniku, za długi powodował natomiast rozdmuchiwanie obłoku pyłu. W kilku próbach jako optymalny czas przyjęto 3 s. Czujki umieszczono umieszczono pryzmatycznie na przeciwległych ściankach pod sufitem komory w układzie nadajnik-odbiornik, nadajnik-lusterko. Wyniki pomiarów były rejestrowane za pomocą układu komputerowego. Wnioski: W wyniku przeprowadzonych badań, z uwzględnieniem zachowania czujek pożarowych dymu, określono rozwiązanie konstrukcyjne w postaci czujki systemu OSID jako czujki, która najlepiej poradziła sobie z pyłem występującym w zabezpieczanych pomieszczeniach. Jest to spowodowane sposobem obróbki sygnału w czujce. Na zadziałanie miały wpływ wielkość pyłów oraz, w mniejszym stopniu, rodzaj pyłu w odniesieniu do gatunku badanego drewna.
Aim: There is a need of fire detection solutions which are sensitive to deceptive signals. They can lead to false fire alarms. One of such signals is the activation of detectors in case of wooden dusts accumulated in the protected area which is regarded by the detector as smoke with large particles. This paper describes selected experimental results on various detectors and different wooden dusts. The aim of this project is to select a detector that is highly resistant to dust particles. Introduction: During designing fire detection systems there is always a problem in a proper selection of fire detectors operating in environments where there are various sources of false alarms. Initially, the influence of cellulose dusts as could be observed during the production of newspapers at the printing house was studied. Then the influence of other dusts was analyzed. During the measurement of smoke particles of different sizes the influence of particles on the detection cannot be explicitly determined. Due to this fact, tested dust was divided taking into consideration the size of the particles where the diameter was 100 μm, 200 μm and 500 μm. It made it possible to test the influence on the operation of the detectors of not only wooden-based materials but also of the size of dust particles. Methodology: During the tests the methodology of measuring the influence of dust on the activation time of detectors was prepared. The pressure of the compressed air was set at 1,5 bars together with the opening time of the valve of the compressed air container in order for the dust to be emitted evenly in the test chamber. If the valve opening time was too short, the dust remained in the container. If it was too long – the dust was blown all over the chamber. The optimum time was set as 3 s. Tested detectors were located by the ceiling of the chamber in the following manner: transmitter-receiver, transmitter-prismatic mirror on opposite walls. Measurement results were registered using a computer system. Conclusions: As a result of the conducted tests, which included the behaviour of fire detectors smoke, the best design solution was determined that best coped with duste present in protected areas. It is OSID smoke detection system. It is a result of how the signal was processed by the detector. The size of dust particles and, to a smaller degree, type of dust with respect to the tested species of wood influenced the operation of the smoke detector.
Źródło:
Bezpieczeństwo i Technika Pożarnicza; 2016, 42, 2; 43-55
1895-8443
Pojawia się w:
Bezpieczeństwo i Technika Pożarnicza
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Analysis of the Problem of False Fire Alarms Generated by Fire Alarm Systems in Poland and Other Selected Countries
Analiza problematyki fałszywych alarmów pożarowych generowanych przez systemy sygnalizacji pożarowej w Polsce i innych wybranych krajach
Autorzy:
Pietrzak, Michał
Chmiel, Michał
Feltynowski, Mariusz
Powiązania:
https://bibliotekanauki.pl/articles/35011322.pdf
Data publikacji:
2022
Wydawca:
Centrum Naukowo-Badawcze Ochrony Przeciwpożarowej im. Józefa Tuliszkowskiego
Tematy:
fire alarm system
fire alarm
false alarm
fire detectors
system sygnalizacji pożarowej
alarm pożarowy
fałszywy alarm
czujka pożarowa
Opis:
Aim: The aim of this article is to discuss the issue of false fire alarms by presenting the most common causes of their occurrence and statistical data, along with the presentation of selected regulatory issues. The article also addresses the issue of minimizing false alarms and the means by which this can be accomplished. Introduction: Due to the fact that triggered fire alarms from fire alarm systems (SSP) initiate a number of triggers of fire protection equipment and can lead to the initiation of fire department actions, it is extremely important to correctly identify the report and confirm its authenticity. However, analysing the statistically available data, it should be noted that unfortunately – despite a number of security methods – false alarms still account for a large percentage of identified calls. This article presents selected false alarm issues from Poland and other countries, such as the United States of America, Germany, Denmark, the Czech Republic, the United Kingdom, Switzerland and Austria. Special attention was paid to statistics on the occurrence of false alarms, formal and legal regulations, causes of false alarms, and used detection elements, including their susceptibility to false reports, along with the methods to reduce them. Methodology: The article uses the results of the authors’ own analysis of the study, made on the basis of the available statistical data from incidents that have occurred, and technical and engineering knowledge of the components of fire alarm system. Conclusions: Analysing the available statistical data, it can be observed that the problem of false alarms is not disappearing. On the contrary – in many countries over the years it is increasing. An increasing percentage of reports from detection systems are false alarms. In addition, considering the available legal regulations, it can be observed that regulations related to false alarms currently focus only on regulating penalties for false alarm reports. Only in a few cases do they concern any other provisions. Nowadays, there are various available methods to protect installations from the occurrence of false alarms, but in order to use them correctly, it is essential that they are properly designed and installed by people with knowledge and experience in this area. Thus, according to the authors, it is reasonable to conclude that the basic requirement for these systems in terms of false fire alarms should be to provide opportunities for obtaining appropriate qualifications and competence among designers, installers and maintainers of SSP systems alike. Keywords: fire alarm system, fire alarms, false alarm, fire detectors.
Cel: Celem artykułu jest omówienie problematyki fałszywych alarmów pożarowych poprzez przedstawienie najczęstszych przyczyn ich występowania oraz danych statystycznych wraz z prezentacją wybranych zagadnień z zakresu regulacji prawnych. Praca porusza także kwestię minimalizacji liczby fałszywych alarmów oraz środków, jakimi może to zostać zrealizowane. Wprowadzenie: Z uwagi na fakt, że wywoływane alarmy pożarowe z systemów sygnalizacji pożarowej (SSP) inicjują szereg wysterowań urządzeń przeciwpożarowych oraz mogą prowadzić do inicjacji działań straży pożarnej, niezwykle istotne jest poprawne rozpoznanie zgłoszenia oraz potwierdzenie jego autentyczności. Jednakże, analizując statystycznie dostępne dane, stwierdzić należy, że niestety – pomimo szeregu metod zabezpieczających – fałszywe alarmy wciąż stanowią duży procent identyfikowanych zgłoszeń. W niniejszym artykule przedstawiono wybrane zagadnienia fałszywych alarmów z Polski i innych krajów, takich jak: Stany Zjednoczone Ameryki, Niemcy, Dania, Czechy, Wielka Brytania, Szwajcaria i Austria. Szczególną uwagę poświęcono statystykom występowania fałszywych alarmów, regulacjom formalnoprawnym, przyczynom powstawania fałszywych alarmów oraz wykorzystywanym elementom detekcyjnym, w tym ich podatności na fałszywe zgłoszenia wraz z metodami pozwalającymi na ich ograniczanie. Metodologia: W pracy wykorzystano wyniki własnej analizy autorów opracowania, dokonanej na podstawie dostępnych danych statystycznych z zaistniałych zdarzeń oraz wiedzę techniczną i inżynierską w zakresie elementów systemu sygnalizacji pożarowej. Wnioski: Analizując dostępne dane statystyczne, można zaobserwować, że problem fałszywych alarmów nie zanika, a wręcz przeciwnie – w wielu krajach na przestrzeni lat nasila się. Coraz większy odsetek zgłoszeń z systemów detekcyjnych stanowią fałszywe alarmy. Dodatkowo, uwzględniając dostępne regulacje prawne, można zauważyć, że przepisy powiązane z fałszywymi alarmami skupiają się obecnie jedynie na regulacji kar za zgłoszenia fałszywych alarmów. Jedynie w nielicznych przypadkach dotyczą one jakichkolwiek innych zapisów. Obecnie dostępne są różne metody pozwalające na zabezpieczanie instalacji przed pojawianiem się fałszywych alarmów, niemniej w celu poprawnego ich wykorzystania niezbędne jest właściwe ich zaprojektowanie i zainstalowanie przez osoby posiadające wiedzę i doświadczenie w tym zakresie. Zasadny jest więc w opinii autorów wniosek, że podstawowym wymaganiem w odniesieniu do tych systemów w aspekcie fałszywych alarmów pożarowych powinno być zapewnienie możliwości zdobycia odpowiednich kwalifikacji i kompetencji zarówno wśród projektantów, instalatorów, jak i konserwatorów instalacji SSP.
Źródło:
Safety and Fire Technology; 2022, 60, 2; 118-132
2657-8808
2658-0810
Pojawia się w:
Safety and Fire Technology
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Fałszywe alarmy pożarowe
Autorzy:
Kośnik, J.
Powiązania:
https://bibliotekanauki.pl/articles/372960.pdf
Data publikacji:
2007
Wydawca:
Centrum Naukowo-Badawcze Ochrony Przeciwpożarowej im. Józefa Tuliszkowskiego
Tematy:
fałszywy alarm pożarowy
System Automatyki Pożarniczej
pole elektromagnetyczne
przyczyny
zaburzenia
urządzenia ochrony przeciwpożarowej
false fire alarm
Fire Automation System
electromagnetic field
causes
disorder
fire protection equipment
Opis:
Nowe systemy radiokomunikacyjne i teleinformatyczne wprowadzają zagrożenia w prawidłowej pracy Systemów Automatyki Pożarniczej. Działające na czujkę pożarową pole elektromagnetyczne telefonu komórkowego GSM lub bezprzewodowej lokalnej sieci komputerowej WLAN, może wywołać fałszywy alarm pożarowy. W analizie przyczyn alarmów posłużono się danymi statystycznymi otrzymanymi z Komendy Głównej PSP.
New generation teleinformatic and radio systems bring distortions into Automatic Fire Systems. A fire picket which receive the electromagnetic field from a GSM mobile phone or from wireless local network (WLAN) can initiate a false fire alarm. Analyze of alarms reasons was realized based on
Źródło:
Bezpieczeństwo i Technika Pożarnicza; 2007, 2; 179-188
1895-8443
Pojawia się w:
Bezpieczeństwo i Technika Pożarnicza
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
False Alarms in the Decision Support System of the State Fire Service
Alarmy fałszywe w Systemie Wspomagania Decyzji Państwowej Straży Pożarnej
Autorzy:
Marzec, Marek
Kuskowski, Jacek
Powiązania:
https://bibliotekanauki.pl/articles/35007526.pdf
Data publikacji:
2022
Wydawca:
Centrum Naukowo-Badawcze Ochrony Przeciwpożarowej im. Józefa Tuliszkowskiego
Tematy:
false alarm
Decision Support System of the State Fire Service
principles of recording incidents
State Fire Service
spatial analysis
alarm fałszywy
System Wspomagania Decyzji Państwowej Straży Pożarnej
zasady ewidencjonowania zdarzeń
Państwowa Straż Pożarna
analiza przestrzenna
Opis:
Aim: The aim of the article is to analyse the recording of false alarm cases using the Decision Support System of the State Fire Service (SWD PSP) in terms of certain requirements for a firefighter creating information from an incident. The cases under consideration belong to one of the types of incidents involving fire protection units. Introduction: Since 1993, when PSP began recording incidents using a database system, the scope of information on false alarms has not changed. To this day, in the incident sheet constituting Annex No. 5 to the regulation on the detailed organization of the national rescue and firefighting system, there is no false alarm as a separate type of incident apart from fire and local emergency. A detailed analysis of the data on false alarms was created in connection with the need to prepare a speech by representatives of KG PSP during a scientific conference organized by CNBOP-PIB entitled “False alarms generated by fire alarm systems”. The authors did not limit themselves to the analysis of alarms from detection installations, and the material was expanded to include a spatial analysis of the occurrence of such events. Methodology: The results of the authors’ own analyses performed on the basis of data collected in SWD PSP and software from the geographic information systems (GIS) were used. In their deliberations, the authors also relied on years of experience in creating and revising the rules for recording incidents in SWD PSP and building a new information system for fire protection units. Conclusions: The scope of data collected by PSP on false alarms is insufficient to carry out accurate and thorough analyses, particularly with regard to the causes of occurrence, detailed information about the facility (site of the incident) and the equipment of buildings with fire alarm systems and others that facilitate or hinder the activities of fire protection units. There is an urgent need to expand the minimum scope of data needed to be recorded in PSP databases. The presented analytical results also indicate that there is insufficient distinction between a local emergency and a false alarm. The upcoming revision of the rules for recording events is expected to include provisions that should improve the quality of data. However, a more detailed analysis will be possible only after the implementation of the newly built SWD PSP, including, among other things, an operational module of the object catalogue.
Cel: Celem artykułu jest analiza ewidencjonowania przypadków alarmów fałszywych za pomocą Systemu Wspomagania Decyzji Państwowej Straży Pożarnej (SWD PSP) pod kątem określonych wymagań wobec strażaka tworzącego informację ze zdarzenia. Rozpatrywane przypadki należą do jednego z rodzajów zdarzeń, w których uczestniczą jednostki ochrony przeciwpożarowej. Wprowadzenie: Od 1993 roku, kiedy rozpoczęto w PSP ewidencjonowanie zdarzeń za pomocą systemu bazodanowego, zakres informacji dotyczących alarmów fałszywych nie uległ zmianie. Do dzisiaj w formatce ze zdarzenia stanowiącej załącznik nr 5 do rozporządzenia w sprawie szczegółowej organizacji krajowego systemu ratowniczo-gaśniczego brak jest alarmu fałszywego jako odrębnego rodzaju zdarzenia poza pożarem i miejscowym zagrożeniem. Szczegółowa analiza danych dotyczących alarmów fałszywych powstała w związku z potrzebą przygotowania wystąpienia przedstawicieli KG PSP podczas konferencji naukowej organizowanej przez CNBOP-PIB pt. „Fałszywe alarmy generowane przez systemu sygnalizacji pożarowej”. Autorzy nie ograniczyli się tylko do analizy alarmów z instalacji wykrywania, a materiał został rozszerzony o analizę przestrzenną występowania tego rodzaju zdarzeń. Metodologia: Wykorzystano wyniki własnych analiz autorów wykonanych na podstawie danych zgromadzonych w SWD PSP oraz oprogramowanie z zakresu systemów informacji geograficznej (GIS). W swoich rozważaniach autorzy opierali się również na wieloletnim doświadczeniu przy tworzeniu i nowelizowaniu zasad ewidencjonowania zdarzeń w SWD PSP oraz budowie nowego systemu informatycznego dla jednostek ochrony przeciwpożarowej. Wnioski: Zakres danych gromadzonych przez PSP w zakresie alarmów fałszywych jest niewystarczający do przeprowadzenia dokładnych i wnikliwych analiz, w szczególności w zakresie przyczyn wystąpienia, szczegółowych informacji o obiekcie (miejscu zdarzenia) oraz wyposażeniu budynków w systemy sygnalizacji pożarowej oraz inne ułatwiające lub utrudniające prowadzenie działań jednostkom ochrony przeciwpożarowej. Istnieje pilna potrzeba rozbudowania minimalnego zakresu danych niezbędnych do ewidencjonowania w bazach danych PSP. Przedstawione wyniki analiz wskazują również na niedostateczne rozgraniczenie pomiędzy miejscowym zagrożeniem a alarmem fałszywym. Najbliższa nowelizacja zasad ewidencjonowania zdarzeń ma zawierać zapisy, które powinny poprawić jakość danych. Dokładniejsza analiza będzie jednak możliwa dopiero po wdrożeniu nowobudowanego SWD PSP, uwzględniającego między innymi moduł operacyjnego katalogu obiektów.
Źródło:
Safety and Fire Technology; 2022, 60, 2; 134-145
2657-8808
2658-0810
Pojawia się w:
Safety and Fire Technology
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-5 z 5

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies