- Tytuł:
- Dust Emission and Efficiency of Local Exhaust Ventilation During Cast Iron Grinding
- Autorzy:
- Gliński, M.
- Powiązania:
- https://bibliotekanauki.pl/articles/89758.pdf
- Data publikacji:
- 2002
- Wydawca:
- Centralny Instytut Ochrony Pracy
- Tematy:
-
local exhaust ventilation
dust
grinders
pyły
systemy wentylacji
wentylacja wyciągowa
szlifierka - Opis:
- A method of determining dust emission and efficiency of its removal by means of local exhaust ventilation from machinery has been described. It complies with Standard No. EN 1093-3:1996 (European Committee for Standardization, 1996) and consists in determining air pollution concentrations in the measurement duct used for air removal from the chamber incorporating devices to be tested. The air volume stream that is pumped is measured at the same time. Test results are presented for dust emission and the efficiency of local exhaust ventilation for cast iron grinding by means of manual power tools and a bench-sander. It has been found that application of local exhaust ventilation contributes to a significant reduction of dust emission with efficiency greater than 90%.
- Źródło:
-
International Journal of Occupational Safety and Ergonomics; 2002, 8, 1; 95-105
1080-3548 - Pojawia się w:
- International Journal of Occupational Safety and Ergonomics
- Dostawca treści:
- Biblioteka Nauki