Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "bioactive fibres" wg kryterium: Temat


Wyświetlanie 1-3 z 3
Tytuł:
New Filtering Antimicrobial Nonwovens With Various Carriers for Biocides as Respiratory Protective Materials Against Bioaerosol
Autorzy:
Majchrzycka, K.
Gutarowska, B.
Brochocka, A.
Brycki, B.
Powiązania:
https://bibliotekanauki.pl/articles/91240.pdf
Data publikacji:
2012
Wydawca:
Centralny Instytut Ochrony Pracy
Tematy:
melt-blown filtering material
bioactive fibres
alkylammonium microbiocides
perlite
bentonite
Opis:
This study evaluated the bioactivity of polypropylene melt-blown filtering nonwovens used in respiratory protective devices (RPD) with a biocidal agent (alkylammonium microbiocides) on 2 mineral carriers. Two types of carriers were tested: a bentonite, with an aluminosilicate base, and a perlite, volcanic glass. High biostatic and biocidal effects of modified nonwovens with biocides were tested against Escherichia coli (E. coli) and Staphylococcus aureus (S. aureus) bacteria. Nonwovens modified with a biocide on a bentonite carrier showed an opposite reaction to a biocide on a perlite. The research also showed that 10% concentration of a biocidal agent on a perlite carrier was sufficient to inhibit the growth of bacteria (100% reduction) placed in the structure of a filtering material during normal use of RPD. A comparison of the biological activity of 2 filtering materials, each containing 10% of a perlite and produced in a laboratory and industrial conditions, showed no statistically significant differences.
Źródło:
International Journal of Occupational Safety and Ergonomics; 2012, 18, 3; 375-385
1080-3548
Pojawia się w:
International Journal of Occupational Safety and Ergonomics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Aspects of Tests and Assessment of Filtering Materials Used for Respiratory Protection Against Bioaerosols. Part I: Type of Active Substance, Contact Time, Microorganism Species
Autorzy:
Majchrzycka, K.
Gutarowska, B.
Brochocka, A.
Powiązania:
https://bibliotekanauki.pl/articles/89937.pdf
Data publikacji:
2010
Wydawca:
Centralny Instytut Ochrony Pracy
Tematy:
filtering material
bioactive fibres
microorganisms
biostatic and biocidal activity
contact time
Opis:
This paper presents the results of a study on antimicrobial activity of polymer filter nonwovens produced by needle-punching or melt-blowing with an addition of disinfecting agents. The first part of the paper discusses how the biocidal activity of nonwovens is a function of the active agent added to the nonwovens, the duration of the contact of microorganisms with nonwovens and the type of microorganisms. The types of fibres and disinfecting agents had a considerable effect on the biocidal activity of nonwovens. The biocidal effect of nonwovens increased with the duration of their contact with microorganisms. Fibre activity differed considerably depending on the species of the microorganism. The microorganisms most sensitive to biocidal activity of the active filter nonwoven were S. aureus, M. flavus and E. coli. There were no biocidal effects on spore-forming bacterium B. subtilis.
Źródło:
International Journal of Occupational Safety and Ergonomics; 2010, 16, 2; 263-273
1080-3548
Pojawia się w:
International Journal of Occupational Safety and Ergonomics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Aspects of Tests and Assessment of Filtering Materials Used for Respiratory Protection Against Bioaerosols. Part II: Sweat in the Environment, Microorganisms in the Form of a Bioaerosol
Autorzy:
Majchrzycka, K.
Gutarowska, B.
Brochocka, A.
Powiązania:
https://bibliotekanauki.pl/articles/91054.pdf
Data publikacji:
2010
Wydawca:
Centralny Instytut Ochrony Pracy
Tematy:
filtering material
bioactive fibres
bacteria, biostatic and biocidal activity
sweat
bioaerosol
filtration
Opis:
The second part of the article presents the results of a study of antimicrobial activity of filter nonwovens with an addition of biocides, as a function of the presence of sweat in the environment and the method of microbe deposition on a nonwoven in the form of a liquid and a bioaerosol. At the same time, the filtration efficiency of nonwovens against microorganisms in the form of a bioaerosol was tested with the dynamic method. The results showed that the addition of sweat on the surface of a nonwoven resulted in an insignificant decrease of biological activity that still remained high. Moreover, an active nonwoven showed biostatic and biocidal activity only when microbes were deposited on the surface in the form of a solution. The nonwoven did not show any biological activity after deposition of microorganisms with the dynamical method in the form of a bioaerosol.
Źródło:
International Journal of Occupational Safety and Ergonomics; 2010, 16, 2; 275-280
1080-3548
Pojawia się w:
International Journal of Occupational Safety and Ergonomics
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-3 z 3

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies