Tytuł:
Comparative analysis of using borehole heat exchangers in Macedonia and in Poland
Autorzy:
Kowalski, T.
Ruvceska, A.
Śliwa, T.
Bieda, A.
Powiązania:
https://bibliotekanauki.pl/articles/298667.pdf
Data publikacji:
2017
Wydawca:
Akademia Górniczo-Hutnicza im. Stanisława Staszica w Krakowie. Wydawnictwo AGH
Tematy:
borehole heat exchangers
geothermal energy
heat pump
hot tap water
Opis:
Using borehole heat exchangers for heating and cooling in different climate conditions were analysed and compared in this paper, considering the heating and cooling modes of the heat pump. Economic analysis were made according to the energy demand for heating, cooling and hot tap water with borehole heat exchangers for a typical family house. The costs for running borehole heat exchangers in Macedonia and Poland were also based on the average monthly temperatures and geological profile of the location.
Źródło:
AGH Drilling, Oil, Gas; 2017, 34, 1; 141-156
2299-4157
2300-7052
Pojawia się w:
AGH Drilling, Oil, Gas
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Health risk assessment resulting from the presence of Legionella bacteria in domestic hot water in public buildings – the results of a pilot study
Autorzy:
Kmiecik, Ewa
Wątor, Katarzyna
Chochorek, Aneta
Kołodziej, Mateusz
Mika, Anna
Krawiec, Arkadiusz
Herzig, Janusz
Powiązania:
https://bibliotekanauki.pl/articles/1841764.pdf
Data publikacji:
2021
Wydawca:
Akademia Górniczo-Hutnicza im. Stanisława Staszica w Krakowie. Wydawnictwo AGH
Tematy:
Legionella pneumophila
tap water
public building
quantitative risk assessment
microbial risk assessment
risk matrix
Opis:
The aim of the study was to assess the risk posed by Legionella bacteria in a public building in Krakow. An old building with internal installation risers of different ages, as well as draw-off points of different types, was selected for testing. Samples were collected during two campaigns. In one sample of the first series of tests, no bacteria were found. During the second series of tests, no Legionella bacilli were found in just one sample and in one sample only 4 colony-forming units were detected. At the remaining draw-off points (water taps), the bacteria count detected were greater than the maximum threshold allowed by legal regulations (admissible threshold for public utility buildings – 100 cfu/100 mL). No morphological differences were observed with respect to the occurrence of specific serogroups. In 14 samples, Legionella pneumophila serogroups 2–14 were found, while the Legionella pneumophila serogroup 1 was only found in one sample. The risk assessment was also carried out based on a semi-quantitative risk matrix approach and as a quantitative microbial risk assessment. The risk matrix approach was successfully implemented for the recognition of the potential risk associated with the Legionella occurrence in a water system. The calculated annual cumulative risk is high. The research shows that even if the weekly inhalation exposure dose (and therefore the calculated risk) is high, the number of Legionella pneumophila illness cases found can be equal to zero. This is probably due to the large uncertainty associated with QMRA determination. The size of the room in which the contaminated water is used also affects the possibility of infection.
Źródło:
Geology, Geophysics and Environment; 2021, 47, 1; 41-52
2299-8004
2353-0790
Pojawia się w:
Geology, Geophysics and Environment
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-2 z 2

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies