Wyszukujesz frazę "electrical resistivity tomography (ERT)" wg kryterium: Temat


Wyświetlanie 1-2 z 2
Tytuł:
Recognition of the flysch substrate using the electrical resistivity tomography (ERT) method to assess the effectiveness of the injection process
Autorzy:
Ćwiklik, Michał
Pasierb, Bernadetta
Porzucek, Slawomir
Powiązania:
https://bibliotekanauki.pl/articles/27310120.pdf
Data publikacji:
2023
Wydawca:
Akademia Górniczo-Hutnicza im. Stanisława Staszica w Krakowie. Wydawnictwo AGH
Tematy:
electrical resistivity tomography ERT
monitoring
Carpathian flysch
injection
Opis:
During the construction of a section of the S-7 Lubień – Rabka-Zdrój dual expressway, located in the area of the Carpathian flysch (Carpathian Flysch Belt, South Poland), damage to the embankment was observed, as well as cracks and depressions in the new pavement. An analysis of the geological and engineering conditions in the area of the road section under construction showed the existence of a complex tectonic structure of the flysch formations, a shallow groundwater table, and numerous landslides. In order to stabilize the road substrate, it was decided to carry out injections, and the locations of these injections were initially geotechnically tested. However, due to the high variability of the geological structure, the target method employed was electrical resistivity tomography (ERT), which performed the survey in two stages. In Stage I, the geoelectrical/geochemical structure of the near-surface zone was identified, and the probable causes of road damage were indicated. This stage was completed by performing the stabilization and sealing process of the ground with an injection mixture. In Stage II, studies were carried out to evaluate the effectiveness of the injection process. The ERT method effectively identified the shallow geological structure and, in particular, delineated the zone of strong fractures in the flysch and areas associated with faults. Using the electrical resistivity tomography method, it was also possible to determine the injection mixture’s approximate penetration depth and the loosening zone’s degree of filling.
Źródło:
Geology, Geophysics and Environment; 2023, 49, 2; 197--202
2299-8004
2353-0790
Pojawia się w:
Geology, Geophysics and Environment
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
2D Electrical Resistivity Tomography interpretation ambiguity - example of field studies supported with analogue and numerical modelling
Autorzy:
Bania, G.
Ćwiklik, M.
Powiązania:
https://bibliotekanauki.pl/articles/184445.pdf
Data publikacji:
2013
Wydawca:
Akademia Górniczo-Hutnicza im. Stanisława Staszica w Krakowie. Wydawnictwo AGH
Tematy:
electrical resistivity tomography ERT
ambiguity
2D inversion
analogue modelling
numerical modelling
Opis:
Single Electrical Resistivity Tomography (ERT) survey was carried out in the Manor and Park Complex in Nowa Huta (Krakow Branice, Poland). It was applied at a small distance and parallel to the longer wall of a monumental building containing an empty 3 m deep basement. Analogue modelling was performed in order to recreate the field study at the proper scale. The laboratory set-up consisted of a water tank where electrodes were mounted to the particular plate, which rested on water surface. The basement model was made out of a non-conducting material. The default and robust inversions were tested and these variants were also considered with the use of numerical modelling. Laboratory experiments have confirmed that zones visible in the interpreted field section are caused by the influence of the building cellar located next to the survey line. Zones of this kind are additionally disturbed by the local geological structure. The experiment has pointed out, among others, that as the distance between the survey line and the underground body increases, the inversion results are still burdened by an object influence. Thus, similar situations can be verified with the use of analogue modelling presented in this paper or 3D numerical one.
Źródło:
Geology, Geophysics and Environment; 2013, 39, 4; 331-339
2299-8004
2353-0790
Pojawia się w:
Geology, Geophysics and Environment
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-2 z 2

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies