Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "microstructure" wg kryterium: Wszystkie pola


Tytuł:
Microstructure and properties of alloyed silver-gold nanoparticles
Autorzy:
Prymak, O.
Ristig, S.
Meyer-Zaika, W.
Raabe, D.
Epple, M.
Powiązania:
https://bibliotekanauki.pl/articles/285180.pdf
Data publikacji:
2014
Wydawca:
Akademia Górniczo-Hutnicza im. Stanisława Staszica w Krakowie. Polskie Towarzystwo Biominerałów
Tematy:
nanoparticles
microstructure
alloyed nanoparticles
Opis:
Alloyed silver-gold nanoparticles recently raised an interest in biomedicine as potential antibacterial and surface-functionalized agents for imaging, drugdelivery, and tumor thermo-therapy [1,2]. The here synthesized alloyed AgAu nanoparticles with different compositions of silver and gold, as determined by atomic absorption spectroscopy (AAS), were prepared by reduction with citrate and tannic acid in aqueous media and subsequently functionalized by the addition of polyvinylpyrrolidone (PVP) [3]. UV spectroscopy confirmed that the particles consisted of alloyed Ag:Au and are not of a separate core-shell structure. The resulting nanoparticles were monodisperse and had a uniform size of ~6 nm, except pure Ag and Ag:Au-90:10, as shown by differential centrifugal sedimentation (DCS) and transmission electron microscopy (TEM). By means of X-ray powder diffraction (XRD) and use of Rietveld refinement [4], the precise lattice parameters, crystallite size and microstrain were determined. Based on the results by XRD, DCS and TEM it was shown, that the nanoparticles were not twinned, except pure Ag and Ag:Au-90:10. Additionally, a distinct deviation from Vegard’s linear rule of alloy mixtures for the lattice parameter was found for the nanoparticles. This effect was also found for AgAu bulk materials, but was much more pronounced in the nanostate. Further investigations of the crystal structure of the alloyed nanoparticles by means of synchrotron radiation might be helpful to gain more information about the interactions of silver and gold atoms.
Źródło:
Engineering of Biomaterials; 2014, 17, no. 128-129; 77
1429-7248
Pojawia się w:
Engineering of Biomaterials
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Influence of microstructure and chemistry of carbon nanomaterials coatings on nerve cells
Autorzy:
Frączek-Szczypta, A.
Wedel-Grzenda, A.
Jantas, D.
Powiązania:
https://bibliotekanauki.pl/articles/285693.pdf
Data publikacji:
2016
Wydawca:
Akademia Górniczo-Hutnicza im. Stanisława Staszica w Krakowie. Polskie Towarzystwo Biominerałów
Tematy:
carbon nanomaterials
nerve cells
microstructure
Źródło:
Engineering of Biomaterials; 2016, 19, 138; 119
1429-7248
Pojawia się w:
Engineering of Biomaterials
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Assessment of the microstructure and mechanical properties of porous gelatin scaffolds
Autorzy:
Morawska-Chochół, Anna
Powiązania:
https://bibliotekanauki.pl/articles/2058382.pdf
Data publikacji:
2021
Wydawca:
Akademia Górniczo-Hutnicza im. Stanisława Staszica w Krakowie. Polskie Towarzystwo Biominerałów
Tematy:
scaffold
microstructure
tissue engineering
gelatin
freeze-drying
mikrostruktura
inżynieria tkankowa
żelatyna
Opis:
Gelatin scaffolds are in the interest of tissue engineering and drug release. The scaffold porosity and microarchitecture are of great importance in proper tissue regeneration. In this work, the freeze-drying method was used to produce the scaffolds. The effect of concentration of the initial gelatin solution and pre- -freezing temperature on the scaffold’s microstructure and microarchitecture (porosity, pores size, shape, and distribution) was evaluated. The mechanical tests of samples were performed. Moreover, the influence of the gentamicin sulphate addition on the gelatin scaffolds microstructure and mechanical properties was also studied. The linear relationship of porosity to the concentration of the initial solution was observed. Therefore, it is possible to obtain a scaffold with a planned porosity. Pores were interconnected with an aspect ratio between 1.5-1.8. For porosity 74 ± 9% the average pore size was 0.7 ± 0.6 mm, with most pores in the range 0.2-0.4 mm. For the samples with porosity 57 ± 14%, the average pore size was 0.2 ± 0.2 mm, with most pores in the range 0.05-0.2 mm. The process of pre-freezing the solution in liquid nitrogen caused the highest porosity of the sample, the smaller pores size and the lower pores size distribution in comparison to the sample pre-frozen in -20°C. The mechanical parameters for all the samples are sufficient for filling bone defects. The addition of a drug to gelatin caused only slight changes in the pore architecture. This material could be applied as a scaffold in the bone loss correlated to bacterial infection.
Źródło:
Engineering of Biomaterials; 2021, 4, 160; 22--27
1429-7248
Pojawia się w:
Engineering of Biomaterials
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Modification of microparticles’ microstructure with carbon dioxide for application as cell carriers in modular tissue engineering
Autorzy:
Mielan, B.
Krok-Borkowicz, M.
Pamuła, E.
Powiązania:
https://bibliotekanauki.pl/articles/284508.pdf
Data publikacji:
2018
Wydawca:
Akademia Górniczo-Hutnicza im. Stanisława Staszica w Krakowie. Polskie Towarzystwo Biominerałów
Tematy:
carbon dioxide
tissue engineering
microstructure
Źródło:
Engineering of Biomaterials; 2018, 21, 148; 102
1429-7248
Pojawia się w:
Engineering of Biomaterials
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Badania mikrostruktury porowatych pokryć modelowych implantów dokostnych
Experimental investigations of porous coatings microstructure of model endoosseous implants
Autorzy:
Uklejewski, R.
Winiecki, M.
Rogala, P.
Powiązania:
https://bibliotekanauki.pl/articles/284916.pdf
Data publikacji:
2009
Wydawca:
Akademia Górniczo-Hutnicza im. Stanisława Staszica w Krakowie. Polskie Towarzystwo Biominerałów
Tematy:
mikrostruktura
implanty
porowate pokrycia
microstructure
implants
porous coatings
Źródło:
Engineering of Biomaterials; 2009, 12, no. 89-91; 113-115
1429-7248
Pojawia się w:
Engineering of Biomaterials
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
The influence of prosthetic elements manufacturing technology on properties and microstructure shaping Co-Cr-Mo alloys
Autorzy:
Augustyn-Nadzieja, Joanna
Szczotok, Agnieszka
Powiązania:
https://bibliotekanauki.pl/articles/1844979.pdf
Data publikacji:
2020
Wydawca:
Akademia Górniczo-Hutnicza im. Stanisława Staszica w Krakowie. Polskie Towarzystwo Biominerałów
Tematy:
Co-Cr-Mo alloys
dental prosthetics
lost wax casting method
selective laser sintering of metal powders (DLMS)
microstructure
hardness
Opis:
The presented publication discusses the test results regarding samples of a prosthetic alloy from the Co-Cr-Mo system. The test samples were obtained by means of two different methods applied in prosthetics laboratories to compare their properties and microstructure. To obtain the samples via the traditional lost wax casting method, the cast alloy Co-Cr-Mo was used, commercially known as Wironit LA. In the case of the modern technique DMLS (Direct Metal Laser Sintering), metallic powder Co-Cr-Mo, called EOS Cobalt Chrome MP1, was used. The samples of both Co-Cr-Mo alloys obtained via the two methods were prepared for metallographic tests; they also underwent microstructural observations with the use of light microscopy (LM) and scanning electron microscopy (SEM), and next they were subjected to hardness tests. The obtained samples demonstrated a dendritic structure. In the samples cast with the lost wax casting method, a segregation of the chemical composition was revealed. The samples obtained by means of the DLMS method were characterized by chemical composition homogeneity. The hardness measurements with the statistical analysis of the measurement results showed a difference between the examined alloys. On the basis of the performed studies, it was stated that the applied methods of manufacturing prosthetic elements make it possible to obtain diversified microstructural and mechanical properties of the alloys. The hardness value significantly affects the subsequent mechanical and finishing treatment of prosthetic elements, such as metal bases of crown caps, bridges, mobile prostheses or other retention elements.
Źródło:
Engineering of Biomaterials; 2020, 23, 156; 24-31
1429-7248
Pojawia się w:
Engineering of Biomaterials
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Mikrostruktura i właściwości warstw tlenoazotowanych wytworzonych w obróbce hybrydowej w niskotemperaturowej plazmie
Microstructure and properties of oxynitrided surface layer produced under hybrid low temperature plasma treatment
Autorzy:
Tarnowski, M.
Sowińska, A.
Oleksiak, J.
Borowski, T.
Czarnowska, E.
Wierzchoń, T.
Powiązania:
https://bibliotekanauki.pl/articles/283793.pdf
Data publikacji:
2013
Wydawca:
Akademia Górniczo-Hutnicza im. Stanisława Staszica w Krakowie. Polskie Towarzystwo Biominerałów
Tematy:
tlenoazotowanie
warstwy powierzchniowe
mikrostruktura
topografia powierzchni
adhezja płytek krwi
oxynitriding
surface layers
microstructure
platelet adhesion
Opis:
Szczególne właściwości tytanu i jego stopów, takie jak: niska gęstość, wysoka wytrzymałość właściwa oraz dobra odporność na korozję i korzystny moduł Younga w zestawieniu z powszechnie stosowanymi stalami chirurgicznymi na implanty kostne powodują, że znajdują one coraz szersze zastosowanie w medycynie. Obecnie jednym z rozwijanych kierunków badań w aspekcie poprawy biozgodności tytanu i jego stopów jest poprawa łączenia się implantu z kością poprzez zwiększenie adhezji oraz aktywacji płytek krwi. Cel ten można osiągnąć poprzez zastosowanie technik inżynierii powierzchni, takich jak metody PVD i CVD, implantację jonów oraz obróbki jarzeniowe, np. tlenoazotowanie w niskotemperaturowej plazmie. Celem niniejszych badań była ocena mikrostruktury (SEM), składu chemicznego (EDS), topografii powierzchni (profilometr optyczny), mikrotopografii oraz mikrochropowatości powierzchni (AFM), mikrotwardości, odporności korozyjnej w roztworze Ringera (metoda potencjodynamiczna) oraz biozgodności warstw tlenoazotowanych wytworzonych podczas procesu tlenoazotowania jarzeniowego w niskotemperaturowej plazmie w temperaturze 650°C. Dyfuzyjna warstwa typu TiO2+TiN+Ti2N+aTi(N) wytworzona na stopie tytanu Ti6Al4V charakteryzuje się wysoką twardością, dobrą odpornością korozyjną i wyższą, niż stop tytanu w stanie wyjściowym, twardością. Badania biozgodności w zakresie adhezji i aktywacji płytek krwi wykazały, że adherowały one w większym stopniu i wykazywały cechy większej aktywacji na warstwach tlenoazotowanych niż na stopie tytanu Ti6Al4V w stanie wyjściowym. Rezultaty wskazują, że wytworzenie warstwy tlenoazotowanej pozwala poprawić właściwości biomateriałów tytanowych w aspekcie integracji z kością.
Specific properties of titanium and its alloys such as: low density, high tensile strength, good corrosion resistance and advantageous elastic modulus in comparison to commonly used surgical steels for bone implants are the reasons for their wider application in medicine. Nowadays, one of the most expandable directions of investigation in the aspect of enhancing biocompatibility of titanium and its alloys is improvement of platelets adhesion and activation to bone implant. This goal can be achieved through the use of several surface engineering methods like PVD and CVD methods, ion implantation and treatment in glow discharge conditions like low temperature plasma oxynitriding. This study was aimed to evaluate the microstructure (SEM), chemical composition (EDS), topography (optical profilometer), microtopography and microroughness (AFM), microhardness, corrosion resistance in Ringer solution (potentiodynamic method) and biocompatibility of oxynitrided surface layer produced at low temperature of glow discharge process. The diffusive surface layer of TiO2+TiN+T2N+aTi(N) type produced on Ti6Al4V titanium alloy exhibited advantageous properties such as high hardness, good corrosion resistance and higher than titanium alloy microhardness. Biocompatibility investigated in range of platelets adhesion and activation revealed that these cells adhered in higher extent and dislayed morphological features of larger activation on oxynitrided layer compared to titanium alloy. Results suggest that produced oxynitrided surface layer have a potential to improve titanium biomaterials in rage of integration with bone.
Źródło:
Engineering of Biomaterials; 2013, 16, 120; 13-18
1429-7248
Pojawia się w:
Engineering of Biomaterials
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Effect of titanium on the sintering and microstructure of Ti-doped hydroxyapatite
Autorzy:
Ślósarczyk, A.
Zima, A.
Paszkiewicz, Z.
Szczepaniak, J.
Powiązania:
https://bibliotekanauki.pl/articles/284252.pdf
Data publikacji:
2009
Wydawca:
Akademia Górniczo-Hutnicza im. Stanisława Staszica w Krakowie. Polskie Towarzystwo Biominerałów
Tematy:
hydroxyapatite
titanium
biomaterials
Źródło:
Engineering of Biomaterials; 2009, 12, no. 89-91; 37
1429-7248
Pojawia się w:
Engineering of Biomaterials
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Mikrostruktura i właściwości stopu Ti-6Al-7Nb po dyfuzyjnej obróbce utwardzającej tlenem
Microstructure and properties of oxygen diffusion strengthened Ti-6Al-7Nb alloy
Autorzy:
Moskalewicz, T.
Wendler, B.
Zimowski, S.
Milc, S.
Czyrska-Filemonowicz, A.
Powiązania:
https://bibliotekanauki.pl/articles/283843.pdf
Data publikacji:
2009
Wydawca:
Akademia Górniczo-Hutnicza im. Stanisława Staszica w Krakowie. Polskie Towarzystwo Biominerałów
Tematy:
stop Ti-6Al-7Nb
mikrostruktura
obróbka tlenem
Ti-6Al-7Nb alloy
microstructure
oxygen diffusion
Opis:
W pracy przedstawiono charakteryzację mikrostruktury, właściwości mikro-mechanicznych i tribologicznych stopu Ti-6Al-7Nb w stanie dostawy oraz po obróbce utwardzającej tlenem. Badania mikrostruktury przeprowadzono za pomocą skaningowej i transmisyjnej mikroskopii elektronowej na próbkach z przekroju poprzecznego. Stwierdzono, że strefa przypowierzchniowa utwardzonego stopu zbudowana była głównie z roztworu stałego tlenu w tytanie α(O). Zastosowana obróbka powierzchniowa istotnie poprawiła twardość oraz właściwości tribologiczne stopu (wzrost odporności na zużycie przez tarcie, zmniejszenie współczynnika tarcia).
The microstructure as well as micro-mechanical and tribological properties of the as received and glow discharge plasma thermal oxidized Ti-6Al-7Nb alloy were examined. Scanning and transmission electron microscopy investigations on cross-section specimens were used for microstructure investigations. The α (O) solid solution enriched by oxygen up to 22at % was mainly present in the near-surface region. Applied sur-face treatment significantly improved microhardness and tribological properties (wear resistance, friction coefficient) of the alloy.
Źródło:
Engineering of Biomaterials; 2009, 12, no. 89-91; 126-129
1429-7248
Pojawia się w:
Engineering of Biomaterials
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Mikrostruktura i właściwości niskotarciowej nanokompozytowej powłoki nc-TiC/a-C na utwardzonym tlenem stopie Ti-6Al-7Nb
Microstructure and properties of low friction nanocomposite nc-TiC/a-C coating on Ti-6Al-7Nb alloy
Autorzy:
Moskalewicz, M.
Wendler, B.
Zimowski, S.
Czyrska-Filemonowicz, A.
Powiązania:
https://bibliotekanauki.pl/articles/284418.pdf
Data publikacji:
2010
Wydawca:
Akademia Górniczo-Hutnicza im. Stanisława Staszica w Krakowie. Polskie Towarzystwo Biominerałów
Tematy:
stopy tytanu
endoprotezy
mikrostruktura
titanium alloys
joint prostheses
microstructure
Opis:
W pracy przedstawiono charakterystykę mikro/nanostruktury, właściwości mikro-mechanicznych i tribologicznych powłoki nc-TiC/a-C osadzonej na utwardzonym powierzchniowo atomami tlenu stopie Ti-6Al-7Nb. Badania mikro/nanostruktury przeprowadzono za pomocą skaningowej i transmisyjnej mikroskopii elektronowej na próbkach z przekroju poprzecznego. Stwierdzono, że powłoka nc-TiC/a-C zbudowana jest z nanokrystalicznych cząstek TiC w amorficznej osnowie węgla. W warstwie wierzchniej utwardzonego tlenem stopu występował roztwór stały tlenu w tytanie α(O). Zastosowana obróbka powierzchniowa istotnie poprawiła mikrotwardość oraz właściwości tribologiczne stopu Ti-6Al-7Nb (wzrost odporności na zużycie przez tarcie, zmniejszenie współczynnika tarcia).
The microstructure as well as micro-mechanical and tribological properties of the nc-TiC/a-C coating deposited on oxygen hardened Ti-6Al-7Nb alloy were examined. Scanning- and transmission electron microscopy investigations on cross-section specimens were used for determination of microstructure and phase composition. It was found that the nc-TiC/a-C coating is composed of TiC nanocrystals embedded in an amorphous carbon matrix. The Ti α(O) solid solution enriched by interstitial oxygen atoms was mainly present in the near-surface region. A particular preliminary surface treatment of specimens significantly improved microhardness and final tribological properties: it increased wear resistance and decreased friction coefficient of the alloy against alumina bearing ball dry ball-on-disc sliding tests.
Źródło:
Engineering of Biomaterials; 2010, 13, no. 99-101; 42-44
1429-7248
Pojawia się w:
Engineering of Biomaterials
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Modification of microspheres’ microstructure for application as cell carriers in modular tissue engineering
Autorzy:
Mielan, B.
Krok-Borkowicz, M.
Pielichowska, K.
Pamuła, E.
Powiązania:
https://bibliotekanauki.pl/articles/285556.pdf
Data publikacji:
2017
Wydawca:
Akademia Górniczo-Hutnicza im. Stanisława Staszica w Krakowie. Polskie Towarzystwo Biominerałów
Tematy:
tissue engineering
polymers
emulsification
Źródło:
Engineering of Biomaterials; 2017, 20, no. 143 spec. iss.; 72
1429-7248
Pojawia się w:
Engineering of Biomaterials
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Degradation analysis of radiosensitizer control release system based on the NMR spectroscopy
Autorzy:
Buszman, A.
Kasperczyk, J.
Jaworska, J.
Powiązania:
https://bibliotekanauki.pl/articles/284117.pdf
Data publikacji:
2012
Wydawca:
Akademia Górniczo-Hutnicza im. Stanisława Staszica w Krakowie. Polskie Towarzystwo Biominerałów
Tematy:
biodegradable polyesters
NMR spectroscopy
hydrolytic degradation
polymeric chain microstructure
Opis:
The degradation process of multilayer radiosensitizer releasing systems was conducted and examined via the nuclear magnetic resonance spectroscopy. Copolymers of glycolide and lactide with different chain microstructure were used as biocompatible drug carriers. Metronidazole was used as radiosensitizer. The changes of copolymers chain microstructure were monitored during 16 weeks of hydrolytic degradation of material in artificial Cerebro-spinal Fluid Solution. This study shows distinct differences in the rate of copolymer degradation and changes of the degree of randomness, directly connected with the type of comonomers and the comonomeric molar ratio. During 16 weeks of hydrolytic degradation, copolymers with L-lactidyl units remain resistant to hydrolysis while materials with D,L-lactidyl units are completely degraded. Examined materials can be used as carriers of agents for different types of short-, mid- and long-term therapies based on control release systems.
Źródło:
Engineering of Biomaterials; 2012, 15, 113; 16-18
1429-7248
Pojawia się w:
Engineering of Biomaterials
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Morphological studies of tissues stabilized by glutaraldehyde and tannic acid
Autorzy:
Turek, B.
Marcinkowski, A.
Cwalina, B.
Nożyński, J.
Dzierżewicz, Z.
Powiązania:
https://bibliotekanauki.pl/articles/286147.pdf
Data publikacji:
2009
Wydawca:
Akademia Górniczo-Hutnicza im. Stanisława Staszica w Krakowie. Polskie Towarzystwo Biominerałów
Tematy:
glutaraldehyde
tannic acid
porcine pericardium
microstructure
nanostructure
Opis:
Despite the disadvantages of glutaraldehyde (GA)-stabilization of tissues, it is the method most often used for xenogeneic tissues preparation. Nowadays, partial elimination of drawbacks of this method is achieved by using GA in the mixture with other crosslinking reagents, which completes the stabilization effects and acts synergistically. The aim of this work was to determine microstructure and nanostructure of porcine pericardium stabilized by GA and tannic acid (TA). The microstructure was examined by optical microscopy and the nanostructure by atomic force microscopy (AFM). Different results on the level of micro- and nanostructure were observed. No essential changes in the tissue morphology after crosslinking with GA and TA were observed under optical microscope, but significant morphological differences were revealed in AFM studies.
Źródło:
Engineering of Biomaterials; 2009, 12, no. 89-91; 32-34
1429-7248
Pojawia się w:
Engineering of Biomaterials
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Microstructure of chitosan-based, ZnO-doped antibacterial composite
Autorzy:
Ciołek, L.
Biernat, M.
Jaegermann, Z.
Zaczyńska, E.
Czarny, A.
Jastrzębska, A.
Olszyna, A.
Powiązania:
https://bibliotekanauki.pl/articles/284490.pdf
Data publikacji:
2017
Wydawca:
Akademia Górniczo-Hutnicza im. Stanisława Staszica w Krakowie. Polskie Towarzystwo Biominerałów
Tematy:
composites
regenerative medicine
bone tissue engineering
Źródło:
Engineering of Biomaterials; 2017, 20, no. 143 spec. iss.; 18
1429-7248
Pojawia się w:
Engineering of Biomaterials
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Microstructure, surface topography and adhesion of zein coatings electrophoretically deposited on titanium substrates
Autorzy:
Maciąg, Filip
Moskalewicz, Tomasz
Hadzhieva, Zoya
Boccaccini, Aldo R.
Powiązania:
https://bibliotekanauki.pl/articles/1844899.pdf
Data publikacji:
2020
Wydawca:
Akademia Górniczo-Hutnicza im. Stanisława Staszica w Krakowie. Polskie Towarzystwo Biominerałów
Tematy:
titanium alloys
corrosion
implants
stopy tytanu
korozja
implanty
Źródło:
Engineering of Biomaterials; 2020, 23, 158 spec. iss.; 21
1429-7248
Pojawia się w:
Engineering of Biomaterials
Dostawca treści:
Biblioteka Nauki
Artykuł

Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies