Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "diagnostic procedure" wg kryterium: Temat


Wyświetlanie 1-2 z 2
Tytuł:
How often are X-rays used as diagnostic tool by healthcare providers in the Mazovian province of Poland
Autorzy:
Bekas, M.
Gajewski, A.K.
Pachocki, K.
Powiązania:
https://bibliotekanauki.pl/articles/877206.pdf
Data publikacji:
2013
Wydawca:
Narodowy Instytut Zdrowia Publicznego. Państwowy Zakład Higieny
Tematy:
X-ray
diagnostic procedure
health care service
diagnosis
treatment
Mazovia region
Polska
Opis:
Background. Within the medical facilities provided by state healthcare services, a universally applied technique for patient diagnosis and treatment relies on ionising radiation; for example in radiotherapy and X-ray (ie. examination). Human exposure to such radiation is not however entirely free of associated health risks. Objectives. To determine and estimate the numbers and types of X-ray based medical procedures that are performed in general and dental radiography, mammography and computer tomography on patients from the Mazovian province in Poland, which included children, women and men subjects. Material and Methods. The numbers of patient subjects undergoing X-rays was estimated by surveying the patient intake in X-ray testing rooms within the healthcare facilities of the Mazovian province. Questionnaires were either dispatched by mail to such healthcare centres or were completed by the X-ray operating staff during the testing of quality control. Results so obtained from the latter, were compared to entries from the X-ray rooms’ register Results. During 2009, the number of X-rays performed were 7612046 equivalent to 1460 examinations per 1000 inhabitants. The majority were done on women ie. 3847961 (50.55%), followed by 3193781 (41.96%) on men and 570 304 (7.49%) for children. Conclusions. Results indicated that the predominating medical procedure used of this type, was for making general diagnoses; especially through using chest radiography. Others included, in descending order; dental X-ray (mainly intra-oral examination), computer tomography (mainly CT head examinations) and mammography procedures. It was also found that the annual numbers of having X-rays has increased compared to previous years.
Wprowadzenie. W placówkach służby zdrowia powszechnie wykorzystywane jest promieniowanie jonizujące w celach medycznych zarówno w diagnostyce jak i terapii. Promieniowanie to nie jest jednak całkowicie obojętne dla zdrowia. Cel. Celem niniejszych badań było określenie i ocena liczby i rodzaju wykonywanych na terenie województwa mazowieckiego procedur medycznych z zakresu diagnostyki ogólnej, stomatologii, mammografii i tomografii komputerowej, osobno dla dzieci, kobiet i mężczyzn. Materiał i metody. Szacowanie liczby badań rentgenowskich przeprowadzono metodę ankietową. Zbierano dane liczbowe z placówek służby zdrowia przy wykorzystaniu opracowanej w tym celu ankiety. Ankiety przekazywano listownie do wylosowanych placówek służby zdrowia na terenie województwa mazowieckiego lub proszono o ich wypełnienie w trakcie przeprowadzania specjalistycznych testów parametrów fizycznych medycznych aparatów rentgenowskich. W tym drugim przypadku weryfikowano jednocześnie zgodność danych w wypełnianych ankietach w stosunku do zapisów w prowadzonych rejestrach badań pacjentów w pracowniach rentgenowskiej. Wyniki. Oszacowano, iż w 2009 roku na obszarze objętym niniejszymi badaniami wykonano łącznie 7612046 diagnostycznych badań rentgenowskich, co daje 1460 badań na 1000 mieszkańców. Najwięcej badań przeprowadzono u kobiet 3847961 (50.55 %), w dalszej kolejności u mężczyzn 3193781 (41.96 %) i dzieci 570304 (7.49 %). Wnioski. W wyniku przeprowadzonych analiz stwierdzono, iż największy udział w strukturze wykonywanych badań rtg miały procedury medyczne z zakresu diagnostyki ogólnej, w tym przede wszystkim badania klatki piersiowej. Na drugim miejscu znajdują się badania rentgenowskie stomatologiczne, głównie wewnątrzustne (punktowe). W dalszej kolejności pod względem liczby wykonywanych badań rtg uplasowały się procedury medyczne z zakresu tomografii komputerowej, wśród których dominowały badania tomograficzne CT głowy oraz procedury medyczne związane z badaniami mammograficznymi. Zaobserwowano wzrost liczby wykonywanych rentgenowskich procedur medycznych w odniesieniu do danych z wcześniej prowadzonych tego typu badań na terenie Polski.
Źródło:
Roczniki Państwowego Zakładu Higieny; 2013, 64, 2
0035-7715
Pojawia się w:
Roczniki Państwowego Zakładu Higieny
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
The assessment of the ionizing radiation dose received by patients during some diagnostic X-ray examinations carried out on the basis of the working procedures in the health care entities
Autorzy:
Bekas, M.
Waniewska, E.
Wardzinski, A.
Wieprzowski, K.
Powiązania:
https://bibliotekanauki.pl/articles/874288.pdf
Data publikacji:
2017
Wydawca:
Narodowy Instytut Zdrowia Publicznego. Państwowy Zakład Higieny
Tematy:
assessment
ionizing radiation
radiation dose
patient
diagnostic method
X-ray method
radiation exposure
working procedure
health care
human health
health risk
Opis:
Background. X-ray examination is a popular and universally used injury and disease diagnostic method. A distinctive X ray examination feature is that it can be done quickly which is extremely important in case of the need for rapid diagnosis of patients in life threatening condition. Another advantage of the X-ray examinations is also relatively low cost of carry. However, X-ray examination involve adverse health effects. During the examination the patient is subjected to ionizing radiation that might have impact on his health. Objective. The aim of this study has been to determine and assess the size of the entrance surface doses (ESD) received by patients during selected X-ray examinations performed on the basis of the medical working procedures available in healthcare entities in Masovian Voivodeship in Poland. Materials and Method. The examinations were conducted for 71 X-ray units located in the Masovian Voivodeship. Measurements of doses received by the patients were based on our own validated test methods. Results. It was found that the range applied to the high voltage in healthcare entities does not always coincide with the values specified in the standard procedures. It was found in the skull projection radiography AP and LAT that the recorded values were from range 60 to 82 kV (the average value of 74 kV) while in accordance with a standard procedure they should be in the range from 65 to 75 kV. Only in case of cervical spine radiography in the AP projection, the LAT exposure conditions were matching with the standard obligatory procedures in Poland. The consequence of selecting exposure conditions are significant differences in the size of the doses the patient receive during the same medical procedures. The greatest range of ESD doses was found during radiography of the thoracic spine in the projection AP and LAT. The projection LAT measured values were in the range of 523 to 10550 μGy (average value 2175 μGy). Conclusions. It is necessary to update immediately the standard procedures and to develop detailed guidelines for the preparation of working procedures in X-ray rooms.
Wprowadzenie. Badania rentgenowskie są powszechnie stosowaną metodą diagnozowania urazów i schorzeń występujących u pacjentów. Największą zaletą tych badań jest szybkość ich wykonania, co jest niezwykle istotne w przypadku konieczności postawienia szybkiej diagnozy medycznej u pacjentów w ciężkim stanie zagrażającym ich życiu. Badania rentgenowskie niosą jednakże ze sobą także negatywne skutki zdrowotne. W trakcie ich przeprowadzania pacjent poddany jest działaniu promieniowania jonizującego, które nie jest obojętne dla zdrowia. Cel. Celem badań było oszacowanie wielkości wejściowej dawki powierzchniowej (ESD) jaką otrzymują pacjenci podczas wybranych badań rentgenowskich przeprowadzonych w oparciu o procedury robocze obowiązujące w placówkach ochrony zdrowia na terenie województwa mazowieckiego. Materiał i metody. Zbadano 71 aparatów rentgenowskich wykorzystywanych w placówkach ochrony zdrowia na terenie województwa mazowieckiego. Pomiary dawek otrzymywanych przez pacjentów podczas badań rentgenowskich przeprowadzono własnymi zwalidowanymi metodami badawczymi. Wyniki. Stwierdzono, iż zakres wartości wysokiego napięcia dobieranego przez personel medyczny na aparatach rentgenowskich w placówkach ochrony zdrowia nie zawsze pokrywa się z wartościami określonymi w procedurach wzorcowych. Stwierdzono, iż w radiografii czaszki w projekcji AP i LAT wartość wysokiego napięcia była od 60 do 82 kV (wartość średnia 74 kV), zaś zgodnie z procedurą wzorcową powinny mieścić się w zakresie od 65 do 75 kV. Najlepszą zgodność pomiędzy wartościami wysokiego napięcia stosowanymi w pracowniach rtg a tymi określonymi w procedurach wzorcowych obowiązujących w Polsce stwierdzono w przypadku radiografii kręgosłupa szyjnego. Konsekwencją tak dobieranych warunków ekspozycji są znaczące różnice w wielkości dawek promieniowania otrzymywanych przez pacjentów dla tych samych procedur medycznych. Największą rozpiętość dawek ESD stwierdzono w trakcie radiografii kręgosłupa piersiowego w projekcji AP oraz LAT. W projekcji LAT zmierzone wartości były w przedziale od 523 do 10550 μGy (wartość średnia 2175 μGy). Wnioski. Niezbędne jest jak najszybsze uaktualnienie procedur wzorcowych oraz opracowanie szczegółowych wytycznych dotyczących przygotowywania procedur roboczych w pracowniach rentgenowskich.
Źródło:
Roczniki Państwowego Zakładu Higieny; 2017, 68, 1
0035-7715
Pojawia się w:
Roczniki Państwowego Zakładu Higieny
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-2 z 2

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies