Tytuł:
Analiza metod określania natężenia przepływów maksymalnych w budynkach wielorodzinnych
The size of a maximum flow for multi-occupied buildings - the analysis of applied methods
Autorzy:
Tuz, P. K.
Powiązania:
https://bibliotekanauki.pl/articles/1826152.pdf
Data publikacji:
2005
Wydawca:
Politechnika Koszalińska. Wydawnictwo Uczelniane
Tematy:
wodomierze
zużycie wody
Opis:
The water works authorities and designers claim that applying standards of PN-92/B-01706 from the year 1992 and PN-ISO 4064-2 causes difficulties in choosing a size of water meter for a residential building. They accuse the standard from the year 1992 of overdimensioning a size of water meters and they accuse PN-ISO 4064-2 that apart from general records there are not any computational formulas that make us closer to calculate the real characteristic flows. Research of flows sizes in buildings within the years 2002÷2005 were carried out in 120 multi-occupied buildings, located in different towns in Poland supplied directly from the municipal water works or hydrophores (pumps controlled using frequency converter or inverter). Each connection with network was equipped with the water meter about the diameter selected tentatively to expected flows and water consumption. They were also adapted by the producer for transmitters of impulses in order to enable connection of the digital recorder. The size of impulses was different and it was adapted for the size of buildings (1÷100 of litres). On the basis of obtained results statistical method to calculate a quantity of flow in a function of parameters that are characteristic of multiroom buildings i.e.: a number of rooms LL, a number of occupants LM., water consumption (per month and per day) was worked out. Results of statistical method were compared with the results received on the basis of standards and law regulations in force. The simulation method of water meters selection is being realized in practice in a dozen or so waterworks companies with very good results. It lets to make apparent losses smaller about 5÷10% although there are also much higher effects. The appropriateness of such conduct is evident in waterworks companies but in many cities administrators of buildings resist this conduct, seeing the danger connected with it. Above all it concerns expanding differences between main water meters - waterworks, and total consumption from household water meters. Apart from that administrators say that according to standard from 1992 there are practically no other legal regulation in force as well as they demand more clearly documentary evidence of the fact of water meter diameter change. However it seems, that both monitoring as well as the simulation method - derivative of monitoring approaching the standard PN-ISO 4064-2 appointed after for use in the directive of the minister of infrastructure.
Źródło:
Rocznik Ochrona Środowiska; 2005, Tom 7; 279-293
1506-218X
Pojawia się w:
Rocznik Ochrona Środowiska
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Analiza wybranych parametrów opisujących zużycie wody w zabudowie wielorodzinnej z punktu widzenia rozbieżności między wskazaniami wodomierzy głównych a sumą wskazań wodomierzy mieszkaniowych
Analysis of selected parameters describing water consumption in multifamily buildings from the point of view of variances between readings of main water meters and sum of flats water meters readings
Autorzy:
Biedugnis, S.
Podwójci, P.
Serejko, G.
Powiązania:
https://bibliotekanauki.pl/articles/1826061.pdf
Data publikacji:
2007
Wydawca:
Politechnika Koszalińska. Wydawnictwo Uczelniane
Tematy:
zużycie wody
wodomierze
Opis:
Wzrastająca cena wody oraz jej powszechne opomiarowanie to, wydaje się, dwie główne przyczyny systematycznego spadku zużycia wody w Polsce od początku lat 90-tych. Ograniczając swoje rozważania do zabudowy wielorodzinnej, można powiedzieć, że suma wskazań wodomierzy mieszkaniowych powinna być równa (przynajmniej teoretycznie i w uproszczeniu) wskazaniu wodomierzy głównych. Praktyka jest jednak inna. Rozbieżności te są bardzo duże, rzędu nawet 20÷30%, ale co ważniejsze przestają być akceptowane przez zarządców nieruchomości oraz lokatorów, którzy w konsekwencji płacą za te różnice w postaci najczęściej dodatkowych opłat eksploatacyjnych. Wielu badaczy w Polsce [1÷3], szczególnie od ostatnich kilku lat, zajmuje się tą problematyką, próbując znaleźć przyczyny tych rozbieżności. Autorzy artykułu postawili sobie za cel analizę zużycia wody w budownictwie wielorodzinnym, w oparciu o dane z Mazowieckiej Spółdzielni Mieszkaniowej w Płocku, ze szczególnym zwróceniem uwagi na rozbieżność pomiędzy wskazaniami wodomierzy głównych a sumą wskazań wodomierzy mieszkaniowych.
Increasing price of water and its common measuring seem to be the main two reasons of systematic reduction of water consumption in Poland from the beginning of the 90s of the last century. Limiting considerations to multifamily buildings, one can say that sum of flat's water meters readings should be equal to (at least theoretically and in simplification) readings of main water meters. But the practice is quite different. Those variances are very big, even 20-30% and more importantly, they are stopping to be accepted by property stewards and occupants, who as the result of it pay for those differences more frequently in form of additional operating fees. Many researchers in Poland especially from the last several years are busy with doing that issues trying to find reasons of those variances. Authors of the paper set the task to analyze water consumption in multifamily housing basing on data of Mazowiecka Spółdzielnia Mieszkaniowa in Płock (Housing Association) paying special attention to variances between readings of flat's and main water meters. Thus, an attempt has been made to find answer to the question: "If in possessed data originating from 131 blocks of flats inhabited by almost 15,000 inhabitants it is possible to find relation between characteristic parameters describing water consumption and aforesaid variances". Finding such relations with information on individual in particular apartments can enable potentially (according to opinion of authors) to identify some irregularities in measuring water consumption, which can result in considered variances between readings of main water meters and sum of readings of flat's water meters. Unit water consumption indicator is dependent on number of inhabitants in the flat and it is bigger than literature reports and standards applied at designing In case of examined flats indicators value was 91 dm3/Md. Determination of real water consumption should consider also structure of inhabitation. Real, unit water consumption, according to authors, is better reflected by mediana value, which is 80 dm3/Md. Hot water to total water consumption ratio, called H/C ratio, is 0.374 for examined flats and is close to values reported in literature. This ratio is not in correlation with number of inhabitants of flat neither with number of apartment block inhabitants.
Źródło:
Rocznik Ochrona Środowiska; 2007, Tom 9; 267-280
1506-218X
Pojawia się w:
Rocznik Ochrona Środowiska
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Analiza zużycia wody i zmienność rozbiorów dla obszaru zasilania Kawie Góry na terenie miasta Częstochowy
Analysis of Water Consumption and Demand Variation in Kawie Góry Supply Area in the City of Częstochowa
Autorzy:
Kępa, U.
Stępniak, L.
Stańczyk-Mazanek, E.
Powiązania:
https://bibliotekanauki.pl/articles/1819249.pdf
Data publikacji:
2013
Wydawca:
Politechnika Koszalińska. Wydawnictwo Uczelniane
Tematy:
zużycie wody
zmienność rozbiorów
Opis:
The correct estimation of water consumption is a very important task, from the theoretical and practical point of view. Distribution systems naturally fluctuate between periods of high and low water usage. Good knowledge of how water use is distributed during the time is critical to accurate water system works. It is particularly important in engineering activity during designing of water supply systems. In Poland from 90ties of the XX century, constant decreased in production and consumption of water is observed. The article has been written on the basis of technical literature renew and the data obtain from Water Supply and Sewerage Company for the Area of Czestochowa. The Company operates and controls the second longest water-pipe network in Poland. The paper presents data concerning water consumption in chosen area in Czestochowa. For the purpose of this study the operating data from the period of 2010–2011 were analyzed. In the area of Kawie Góry are single-family houses only, the buildings are connected to the sewer system, hot water is prepared locally. Number of customers supplied from the water network is 1,472 persons. The following parameters as: unitary water consumption [dm3/P d], day and hour coefficient peaking factor [Nd, Nh] were calculated. The water consumption in households was 103dm3/P d in 2010 year and 95dm3/P d in 2011 year. The day coefficient peaking factor was Nd = 1,94–3,5, the hour coefficient peaking factor was Nh = 1,85–2,69. It was shown, that calculated ratios for the area of Kawie Góry are different from the values in the existing literature. Similar differences have been presented by other authors too. It seems advisable to carry out extensive studies to verify these values. They can be used in design practice then and corresponds to the currently operating conditions.
Źródło:
Rocznik Ochrona Środowiska; 2013, Tom 15, cz. 3; 2546-2562
1506-218X
Pojawia się w:
Rocznik Ochrona Środowiska
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Analiza wybranych czynników kształtujących zużycie wody w budynkach wielorodzinnych
Analysis of selected factors characterizing water consumption in multi-family buildings
Autorzy:
Pasela, R.
Gorączko, M.
Powiązania:
https://bibliotekanauki.pl/articles/1819022.pdf
Data publikacji:
2013
Wydawca:
Politechnika Koszalińska. Wydawnictwo Uczelniane
Tematy:
zużycie wody
budynki wielorodzinne
housing association
water consumption
Opis:
In the paper the water consumption level is correlated with some flats conditions. The study based on the 6 years data of more 500 comfortable flats located in multi-familiar buildings in Torun. The water consumption is hardly predicted, because belongs on many parameter, e.g. time, actual population and his periodical fluctuations, technical equipment, weather conditions meteorological. The individual habits, the organization of the day and the work mode are some important fast variable parameters too. The individual average factors for cold, hot and integral water consumption were estimated. The highest observed value was 228 dm3/Md (1 person in M-5 flat) and the minimal one 42 dm3/Md (6 person in M-3 flat). The average water consumption level recommended for projects are: 103 dm3/Md for M-5 flat, 90 dm3/Md for M-4, 89 dm3/Md for M-2 and at last 83,5 dm3/Md for M-2. The propositions are obviously less than the officially recommended (160 dm3/Md). The described time 6 years the water consumption in investigated urban area of Torun goes to stabilization on level 98 dm3/Md. The value was calculated on more 3500 observations. The gamma distribution can be applied for studies of the water consumption (cold, hot or global). The exponential model appears to be good for correlations of the flats occupations and water consumption level. The parameter values decreases to the flat occupation enhancement. The relations of water usage and a flat occupational level, it’s inside area and standard were estimated too. The increasing of the average individual flat area effects the water consumption too. The feature is confirmed by high values of correlation factors. Perhaps the flat existence needs some water volume, independently on flat occupation level. Presented investigations explain because the decreasing of flat occupation not effects by proper downing of the water consumption. The modeling of water consumption processes investigations appears to be suitable in urban projects, separately for the water requirement predictions.
Źródło:
Rocznik Ochrona Środowiska; 2013, Tom 15, cz. 2; 1658-1672
1506-218X
Pojawia się w:
Rocznik Ochrona Środowiska
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Struktura zużycia wody w budynkach jednorodzinnych
Structure of water consumption in single-family buildings
Autorzy:
Żuchowicki, A. W.
Gawin, R.
Powiązania:
https://bibliotekanauki.pl/articles/1818763.pdf
Data publikacji:
2013
Wydawca:
Politechnika Koszalińska. Wydawnictwo Uczelniane
Tematy:
zużycie wody
budynki jednorodzinne
water consumption
single-family buildings
Opis:
The article presents a structure consumption water 43 single-family buildings located in Koszalin. Research spanned a period of 6 years from 2005 to 2011 r. This scientific description, which contain water meters readings shows, how is water consumption and how uneven it is. Results obtained in the study were compared with results reported by other authors.
Źródło:
Rocznik Ochrona Środowiska; 2013, Tom 15, cz. 1; 924-929
1506-218X
Pojawia się w:
Rocznik Ochrona Środowiska
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Analiza zużycia wody w budynkach wielorodzinnych zlokalizowanych na terenie Koszalińskiej Spółdzielni Mieszkaniowej "Nasz Dom"
Analysis of water consumption in multi-family buildings located in the Koszalin housing association "Nasz Dom"
Autorzy:
Żuchowicki, A. W.
Matczyna, R.
Powiązania:
https://bibliotekanauki.pl/articles/1819792.pdf
Data publikacji:
2009
Wydawca:
Politechnika Koszalińska. Wydawnictwo Uczelniane
Tematy:
zużycie wody
budynki wielorodzinne
Koszalin
water consumption
multi-family buildings
Opis:
Wodomierze to urządzenia służące do pomiaru objętości przepływającej wody. Na podstawie licznych aktów prawnych [1, 2, 3] wodomierze podlegają kontroli metrologicznej (w ramach zatwierdzenia typu, legalizacji pierwotnej i ponownej). W instalacjach wodociągowych stosuje się wodomierze wirnikowe, które dzielą się na wodomierze skrzydełkowe i śrubowe. Wodomierze skrzydełkowe przeznaczone są do pomiaru małych objętości wody i były budowane o średnicach nominalnych od DN=15 mm do DN=40 mm, obecnie są także wytwarzane o średnicy DN=50 mm. Wodomierze śrubowe przeznaczone są do pomiaru większych objętości wody i mają średnice od DN > 50 mm. W instalacjach wodociągowych stosowane są wodomierze skrzydełkowe w całym zakresie średnic oraz wodomierze śrubowe do DN 150 mm, ponadto wodomierze o średnicach od DN 200 do DN 400 mm stosowane są w stacjach wodociągowych. Najczęściej w budownictwie mieszkaniowym montuje się wodomierze mieszkaniowe skrzydełkowe, charakteryzujące się następującymi strumieniami (które wyznaczają charakterystyczne przedziały błędu pomiarowego w zależności od wielkości przepływu - rys. 1) [5, 10]
The paper presents analysis of water consumption in multi-family buildings located in the Koszalin Housing Association "Nasz Dom". Analysis was made for the period of quarterly accounts from May 2005 till December 2008. Investigations were conducted for 3 multi-family buildings. During analysis of water consumption, exchange of main water meters was taken into account. The growth of water consumption measured on main water meter was noticed after the exchange of measuring devices. But the change of total consumption measured by flat water meters was not noticeable. Analysis shows also, that difference between readings from flat water metres and main water meters was within the range of admissible values of differences. In buildings at Karłowicza 5A-B this difference was 2.55%, at 4 Marca 16-16A 8.12%and at Zwycięstwa 186 11.97%. Such situation proves that main water meters we (aswell as flat water meters) were selected correctly and properly installed. During analysis of water consumption in selected multi-family buildings control measurement of water meters was not taken into account, because of the lack of the possibility to conduct such measurements. Authors recommend that every Housing Association, as the administrator squaring up occupants for water consumed, should carry out systematic analyses of water consumption in order to control differences of indications between main and flat water meters. When such difference is too high Housing Association should makedecision about evaluation, repair or exchange of the water meter.
Źródło:
Rocznik Ochrona Środowiska; 2009, Tom 11; 663-674
1506-218X
Pojawia się w:
Rocznik Ochrona Środowiska
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Analiza produkcji i zużycia wody w Pile
Analysis of production and consumption of water in Pila
Autorzy:
Żuchowicki, A. W.
Telega, M.
Powiązania:
https://bibliotekanauki.pl/articles/1819625.pdf
Data publikacji:
2010
Wydawca:
Politechnika Koszalińska. Wydawnictwo Uczelniane
Tematy:
produkcja wody
zużycie wody
spadek zużycia wody
water production
water consumption
decrease in water consumption
Opis:
Od 90-tych lat XX wieku obserwujemy ciągłe zmiany w produkcji i zużyciu wody. Spowodowane jest to różnymi czynnikami, m.in. większą świadomością odbiorcy na temat wartości wody oraz wzrostem ceny 1 m3 zużywanej wody. Orientacyjne wskaźniki zapotrzebowania na wodę w Polsce określa Rozporządzenie Ministra Infrastruktury z dnia 14 stycznia 2002 r. w sprawie określenia przeciętnych norm zużycia wody (Dz. U. Nr 8, poz. 70) [5]. Wielkości zużycia wody zależą od standardu wyposażenia mieszkań poszczególnych odbiorców. Tendencja spadkowa zużycia i produkcji wody jest systematycznie odnotowywana również w innych krajach Europy [2], jednak w Polsce wartości te należą do jednych z najniższych w Europie.
From 90ties of the twentieth century, constant changes in production and consumption of water is observed. It is caused by various factors, including increased awareness of customers about the value of water and increase of price of 1 m3 of consumed water. Downward trend of consumption and production of water is systematically recorded in other European countries, but in Poland, these values are among the lowest in Europe. This paper presents data concerning water production and water consumption in Piła. Pila is a city located on the border of Western Pomerania and Wielkopolska. It covers area of 102.7 km2. Population of Piła reaches approximately 75000. Water for inhabitants of Piła is taken from the water supply network with diameters ranging from 80 to 600 mm, with a total length of 147.1 km (excluding household water connections). Water supply network is made mostly of cast iron pipes (72%). One of the major factors determining the efficiency of water supply in Piła is the age of existing pipelines. Development of the city id followed by expansion of existing water mains, but still the largest share of Pila's pipeline network is constructed before 1945 (35%) (Figure 1). The analysis shows the changes of water consumption are present over the years covered by the research. Decline in production and consumption of water is sharply outlined and is in accordance with downward trend occurring in many Polish cities.The research covered the years 1995-2005 and covered water production for the whole city and water consumption in households. Produkcja wody w badanym okresie ulega corocznym zmianom. Między rokiem 2000 a 2005 różnica w produkcji wody wyniosła 399 tys. m3. W poprzednich pięciu latach, tj. od roku 1995 do roku 2000 różnica produkcji wody wyniosła 1506 tys. m3 (rysunek 2). Water production during the research period changed annually. Between 2000 and 2005 the difference in water production was 399 thousands of m . In the previous five years, that is from 1995 to 2000 difference in water production amounted to 1,506 thousand of m3 (Figure 2).The data of water consumption in the years 1995-2000 shows also drop in consumption of 26.9%, this result is similar to result concerning decrease of water production. While the decrease in water consumption in subsequent studied years (2000-2005) differs from the production of water and amounts to 14.8% (Figure 5). On the basis of the analysis it is possible to state that real water consumption index are much lower in comparison with values that were taken into consideration during water-pipe network design stage. On the basis of obtained data, real values differ from those assumed and in 2005 year. Latest values are 103 dm3/Mday from data of water consumption in households, and 165 dm3/M-day from calculated on the basis of water production.
Źródło:
Rocznik Ochrona Środowiska; 2010, Tom 12; 313-324
1506-218X
Pojawia się w:
Rocznik Ochrona Środowiska
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Zużycie wody w budownictwie wielorodzinnym - wybrane zagadnienia
Water consumption in the multi-family housing selected issues
Autorzy:
Podwójci, P.
Kozłowski, M.
Krysiuk, M.
Powiązania:
https://bibliotekanauki.pl/articles/1819448.pdf
Data publikacji:
2011
Wydawca:
Politechnika Koszalińska. Wydawnictwo Uczelniane
Tematy:
wodomierz
zużycie wody
budownictwo wielorodzinne
statystyka zużycia wody
water meter
water consumption
multi-family housing
water consumption statistics
Opis:
Największe zużycie wody w Polsce można było zaobserwować w latach osiemdziesiątych ubiegłego wieku. Wynikało to w dużej mierze z braku opomiarowania odbiorców oraz niskiej świadomości społecznej. Wraz z zamontowaniem wodomierzy oraz sukcesywnym wzrostem cen wody rozpoczęła się tendencja zniżkowa zużycia wody przez przeciętnego mieszkańca. Rozpoczęto również prace mające na celu zminimalizowanie strat wody - instalacja nowej, szczelnej armatury czerpalnej, wprowadza się nowe wytyczne przy projektowaniu instalacji wodociągowej (obowiązek montażu wodomierzy), a jej metalowe elementy zastępuje się odpowiednikami z tworzyw sztucznych [2, 11]. Pomimo tak wielu zabiegów, w budownictwie wielorodzinnym nadal pojawiały się konflikty przy rozliczaniu mieszkańców za wodę. Ich źródłem były rozbieżności pomiędzy wskazaniem wodomierza głównego (WG), a sumą wskazań wodomierzy mieszkaniowych (WM). To właśnie tę różnicę nazywamy stratami pozornymi. Przy założeniu, że wszystkie wodomierze instalacji są sprawne i wskazują zawsze faktyczną ilość wody jaka przez nie przepłynęła, wskazanie na WG powinno być równe WM. Niestety prawie nigdy nie ma to miejsca. Przyczyn jest wiele, najczęstsze to: jakość wodomierzy, nieszczelności w instalacji, kradzież wody poprzez ingerowanie w działanie wodomierzy mieszkaniowych. Tu przechodzimy do klas wodomierzy. To od nich zależy jakie dane urządzenie spełnia standardy. Im wyższa klasa wodomierza tym jego czułość i dokładność pomiaru jest większa. Każdy wodomierz zarówno ten domowy jak i zbiorczy (np. główny) ma swój próg rozruchu poniżej którego albo wcale nie pracuje, albo jego wskazania obarczone są dużym błędem pomiarowym [3]. Przy wodomierzu odpowiedniej klasy może zostać zmierzona nawet ilość wody wypływająca z cieknącego kranu. Im większy wodomierz (większa średnica DN) tym zwykle ma wyższy próg rozruchu, a co za tym idzie mniejszą dokładność przy niewielkich przepływach wody. Tak więc w budownictwie wielorodzinnym przepływ, który wystarczy do poruszenia pojedynczego wodomierza mieszkaniowego może nie wystarczyć do poruszenia wodomierza głównego. W artykule podjęto próbę oceny wielkości strat pozornych zużycia wody oraz identyfikację głównych czynników mających wpływ na to zjawisko. Dodatkowo spróbowano określić wpływ przerw reklamowych na zużycie wody. Badania (analizę) podzielono na trzy części, odpowiednio w części: A. Próbowano określić jaki wpływ na wielkość strat pozornych ma "starzenie się" wodomierzy mieszkaniowych (od ostatniej legalizacji), B. Próbowano określić czy przepływ mały/duży (rozbiory dzienne/nocne) ma wpływ na wielkość strat pozornych, C. Próbowano określić wpływ przerw reklamowych na zużycie wody. Autorzy artykułu od wielu lat zajmują się szeroko rozumianą problematyką zużycia wody w budownictwie wielorodzinnym.
The highest water consumption in Poland was recorded in the eighties of the last century. It arose due to the lack of consumer's measurement and low public awareness. Along with the installation of water meters and a gradual increase of water prices, a decline of water consumption by the average citizen has begun. The efforts to minimize the loss of water were started - the installa-tion of a new, sealed tap fittings, new guidelines for the design of water system were introduced (the mandatory installation of water meters), and its metal parts replaced with plastic equivalents. Despite so many efforts in the multi-family housing, there are still conflicts in squaring residents for water. It is caused by the discrepancy between indications of main water meters (MWM) and the sum of the indications of residential water meters in the multi-family housing (WM). This discrepancy is called the apparent loss. Assuming that all water meters in installation are in good working order and always show the actual amount of water that flowed by, the reading of the MWM should be equal to WM. Unfortunately, it almost never occurs. There are many causes of that phenomenon, the most common are: the quality of water meters, leaks in the installation, theft of water by interfering with the operation of residential water meters. Which standards the water meter complies depends on their classes. The higher the class of the water meter, the higher sensitivity and accuracy. Each water meter of both the home and the collective (e.g. main one) has a starting threshold below which the water meter does not work at all or its readings carry a high measuring error. Thanks to proper class of water meters, even the amount of water flowing from the leaky tap can be measured. The larger the water meter (larger diameter DN) the higher starting threshold and thus less accuracy at low flow rates. In the article, the authors have made an attempt to determine a real specific water consumption and elements which can have an influence on discrepancy between indications of main water meters and the sum of the indications of residential water meters in the multi-family hous-ing In addition, an attempt to determine the impact of advertising breaks on water consumption was made. Research was divided into three parts, respectively: A. An attempt to determine the impact of "aging" of water meters on the amount of apparent losses (since the last attestation); B. An attempt to determine whether the small / large flow (daily/ night consumption) affects the apparent losses; C. An attempt to determine the impact of advertising breaks on water consumption. The studies allow to formulate the following conclusions: 1. Apparent water losses are inevitable. However, they can be eliminated to a reasonable value by the introduction of modern measuring equipment subjected to periodic attestation. 2. Night period, and large jumps of water flow are the largest source of apparent losses. 3. Advertisements breaks during broadcasting the program on television have a definite influence on the water consumption.
Źródło:
Rocznik Ochrona Środowiska; 2011, Tom 13; 1653-1665
1506-218X
Pojawia się w:
Rocznik Ochrona Środowiska
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Jednostkowe zużycie wody oraz straty pozorne w budownictwie wielorodzinnym na przykładzie mazowieckiej spółdzielni mieszkaniowej w Płocku
Unit water consumption and apparent losses in the multi-family housing on the example of mazovian housing association in Płock
Autorzy:
Podwójci, P.
Serejko, G.
Wojciechowski, M.
Biedugnis, S.
Chojnacka, P.
Smolarkiewicz, M.
Czapczyk, A.
Powiązania:
https://bibliotekanauki.pl/articles/1819731.pdf
Data publikacji:
2009
Wydawca:
Politechnika Koszalińska. Wydawnictwo Uczelniane
Tematy:
wodomierz
jednostkowe zużycie wody
budownictwo wielorodzinne
straty pozorne
water meter
unit water consumption
multi-family housing
apparent loss
Opis:
Urządzeniem mierniczym służącym do rejestrowania ilości zużytej wody jest wodomierz i to od jego jakości oraz poprawności działania zależy w znaczącej mierze opłata czynszowa, jaką ponosi lokator. Wszelkiego rodzaju nieprawidłowości związane z funkcjonowaniem wodomierza oraz szeroko rozumianegopomiaru ilości zużytej wody, przekładają się na powiększenie różnicy pomiędzy wskazaniami wodomierzy głównych a sumą wskazań wodomierzy mieszkaniowych. Ta zaś różnica "wraca" do lokatora w postaci dodatkowych kosztów, często pod postacią dodatkowych opłat eksploatacyjnych. Można zatem powiedzieć, że prawidłowa gospodarka wodomierzowa i rozliczeniowa, prowadzona zarówno przez zarządcę nieruchomości jak i przedsiębiorstwo wodociągowe (ma to szczególne znaczenie w przypadku budownictwa wielorodzinnego), musi się opierać na odpowiednim doborze i rzetelności wskazańwodomierzy domowych i mieszkaniowych.
A device used to measure the volume of water usage is a water meter and on its quality and working correctness depend the water rate which lodger is supposed to pay. All types of incorrectness connected with functioning of water meters and measurement of water consumption have an influence on the discrepancy between indications of main water meters and the sum of the indications of residential water meters in the multifamily housing. This discrepancy is visible for the lodger in the form of additional costs and additional exploitation fees. It can be stated that proper water meters economy and payments management, run not only by the property administrators but also by water meters companies, should be based on appropriate selection and integrity of measurement of water meters. In the article, the authors have made an attempt to determine a real specific water consumption and elements which can have an influence on discrepancy between indications of main water meters and the sum of the indications of residential water meters in the multi-family housing basing on the data coming from the Mazovian Housing Association in Płock in the years of 2003-2008. The analysis covered 131 multifamily buildings (about 5049 flats in which approximately 13379 persons are registered). The first part of researches (covered all 131 buildings) the authors used as a background to determine characteristic factors describing the water consumption in the multi-family housing. In the second part, covered 6 selected buildings (266 flats, 746 registered persons), the authors tried to determine the influence upon exchange of water meters on the water consumption and apparent water losses. The main conclusion occurring from the researches is: "The incorrect installation methods of water meters and their metrological properties are mainly the decisive reasons of discussed discrepancies." Other parameters describing the water consumption in the multi-family housing undergo slight changes with relation to the previous years.
Źródło:
Rocznik Ochrona Środowiska; 2009, Tom 11; 1143-1153
1506-218X
Pojawia się w:
Rocznik Ochrona Środowiska
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-9 z 9

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies