Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "zanieczyszczenia ścieków" wg kryterium: Temat


Wyświetlanie 1-6 z 6
Tytuł:
A study on environmental improvement of the river Bagmati of Kathmandu Valley, Nepal
Badania nad środowiskowej poprawą rzeki Bagmati w Dolinie Kathmandu, Nepal
Autorzy:
Shrestha, R.
Krebs, P.
Roeske, I.
Powiązania:
https://bibliotekanauki.pl/articles/1826209.pdf
Data publikacji:
2003
Wydawca:
Politechnika Koszalińska. Wydawnictwo Uczelniane
Tematy:
zanieczyszczenia wód gruntowych
rzeka ścieków
biologiczne oczyszczanie ścieków
Opis:
The Kathmandu valley, which has been listed in the world heritage list in 1979, comprises the city of Kathmandu, the capital of Nepal, the city of Lalitpur, the third largest city in Nepal and Bhaktapur city. The area is 899 km2, with 1.5 million populations [1]. Tourism is one of the major sources of revenue in the valley. The river Bagmati runs somewhat in the middle of it. The valley is facing a challenge from it. It is the well-known polluted river in Nepal. It is mainly polluted by the domestic and industrial wastewater [2]. Waste stabilization ponds are large shallow basins enclosed by earthen embankments in which wastewater is treated naturally. They indicate that the easily degradable organic materials from the inflowing sewage are processed by bacteria in the same way as in activated sludge system. This technology is cheaper than the activated sludge system because there is no aeration, no desludging, easy operation, etc. The use of oxidation ponds or stabilization ponds in the treatment of wastewater is old technology. The studies on stabilization ponds for domestic sewage and other wastewater in India and other tropical and sub-tropical countries show highly successful results [3]. These results are prompted the study presented in this paper. This study is concerned with the fact that the river Bagmati of the Kathmandu valley are polluted and degraded, in a broad sense which includes the loss of cultural and religious values as well as reduced environmental quality and physical dimensions. The main and most important cause of the river Bagmati pollution is inadequate wastewater disposal. Briefly, we can say due to discharge of untreated sewage and industrial effluents into biological oxidation method can be used to treat these wastewaters.
Dolina Kathmandu w Nepalu została wpisana na listę dziedzictwa światowego w 1979 roku. Turystyka jest jednym z głównych źródeł dochodu w dolinie. Rzeka Bagmati biegnie przez jej środek. Dolina Kathmandu staje wobec wyzwania spowodowanego przez tą rzekę. Zrzut przemysłowych i komunalnych ścieków do rzeki Bagmati przez dwie dekady spowodował stopniowe pogorszenie jakości jej wód. Obecnie, można powiedzieć, że rzeka Bagmati, która jest symbolem czystości i świętości dla ludzi w Nepal, jest "rzeką ścieków", która może nawet zanieczyszczać wody gruntowe. Celem badań jest zasugerowanie możliwej do wykonania oczyszczalni ścieków z beztlenowymi stawami wstępnymi i tlenowymi lagunami, które są popularne w krajach z gorącym klimatem. Ten system oczyszczania ścieków w stawach utleniających jest bardzo prosty w porównaniu do innych systemów z biologicznym oczyszczaniem ścieków. Stawy mogą skutecznie oczyszczać szeroki zakres ścieków komunalnych, przemysłowych i rolniczych. Są w stanie stawiać czoła szokowym ładunkom organicznym i hydraulicznym albo co najmniej mają dużo większą pojemność buforową (również w stosunku do napływu wód burzowych) niż inne systemy oczyszczania ścieków. Poza tym, podano sugestie, by polepszyć jakość wód rzeki Bagmati.
Źródło:
Rocznik Ochrona Środowiska; 2003, Tom 5; 59-65
1506-218X
Pojawia się w:
Rocznik Ochrona Środowiska
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Monitoring zanieczyszczeń dostających się do rzeki Biebrzy z oczyszczalni ścieków w Goniądzu
Monitoring contaminants discharged to Biebrza River from sewage treatment plant in Goniądz
Autorzy:
Skoczko, I.
Powiązania:
https://bibliotekanauki.pl/articles/1826287.pdf
Data publikacji:
2001
Wydawca:
Politechnika Koszalińska. Wydawnictwo Uczelniane
Tematy:
monitoring
zanieczyszczenia rzeki
oczyszczalnia ścieków
klasyfikacja wód
Opis:
Źródła Biebrzy, największego po Bugu dopływu Narwi znajdują się w pobliżu granicy państwa, kilka kilometrów na wschód od Dąbrowy Białostockiej i na południe od miejscowości Nowy Dwór na bagnach Jałta, u podnóża wzgórz morenowych zaliczanych do mezoregionu Wzgórz Sokólskich. Ujście Biebrzy znajduje się koło wsi Ruś, na 248,5 km biegu Narwi. Biebrza, po przebyciu od źródła w kierunku północnym około 10 kilometrowego odcinka na obszarze wysoczyzny, wpływa na obszar pradoliny, zwanej Kotliną Biebrzańską. Przyjęty w Polsce system klasyfikacji rzek odbiega w sposób istotny od systemów obowiązujących w krajach Unii Europejskiej. W krajach tych nie stosuje się jednolitej metody klasyfikacji wód. W zależności od planowanego sposobu wykorzystania wody, zgodnie z odpowiednimi dyrektywami, określa się zakres badanych wskaźników, metodyki referencyjne oraz częstotliwość prowadzenia badań. Dla poszczególnych rodzajów przeznaczenia wód takich jak: woda przeznaczona do picia, kąpieli, hodowli ryb łososiowatych, hodowli ryb karpiowatych określone są maksymalne stężenia zanieczyszczeń. Różnice obu systemów są zasadnicze, tak pod względem liczby stosowanych wskaźników, jak i ich wartości, a także metod oceny osiągania przez monitorowane wody płynące odpowiednich klas. Polskie wymagania w tym zakresie są znacznie ostrzejsze, co prowadzi do zaniżenia ocen jakości wód rzek polskich podczas gdy rzeczywisty stopień zanieczyszczenia wód nie odbiega zasadniczo od podobnych parametrów w innych krajach europejskich. Przygotowania Polski do członkostwa w UE spowodują konieczność dostosowania obowiązującej dotychczasowej klasyfikacji wód do wymogów unijnych. W punkcie pomiarowo-kontrolnym w Goniądzu na analizowanym odcinku, normom wód I klasy odpowiadała jedynie zawartość w wodzie azotu amonowego. Wartości azotu azotynowego mieściły się w granicach II klasy czystości. Normom wód III klasy czystości odpowiadają wartości fosforanów i z tego też powodu wody w tym punkcie określono jako trzecioklasowe.
Goniądz is the city in province podlaskie within Biebrzańska Valleys, over Biebrza. Situated on agricultural area region, it is centre and basic tourist attraction of these regions. Interesting and incomparable in Europe animals and plants attract biologists, and there is a necessity of continuous monitoring of contaminants discharged with treated sewage. From April 2000 to March 2001 nine series of tests of contaminants getting to the Biebrza river along with treated sewage from municipal sewage treatment plant in Goniądz were made. In the treated sewage apart from basic parameters compounds derivating from fenoxyacids were determined. They are a component of a group of crop protection products - herbicides, which exterminate mono- and dicotyledonous weeds. Such herbicides are popular in the agricultural region of north-eastern Poland. Basing on the results gained during research, it may be stated, that sewage treatment plant in Goniądz discharges well treated sewage to the receiving waters as regards concentration of biogenic as well as organic compounds. At Goniądz measurement-controlling point, in the analysed section, only concentration of ammonium nitrogen fulfilled standards of the first class waters. Concentration of nitrite nitrogen fulfilled standard of the second class of cleanness. Concentration of phosphates fulfilled only standard of the third class of cleanness, and that is why water at this point is are numbered among the third class of cleanness.
Źródło:
Rocznik Ochrona Środowiska; 2001, Tom 3; 169-180
1506-218X
Pojawia się w:
Rocznik Ochrona Środowiska
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Efektywność usuwania substancji tłuszczowych w układzie oczyszczania ścieków miejskich
Efficiency of grease substances removal in a municipal sewage treatment Plant
Autorzy:
Boguski, A.
Powiązania:
https://bibliotekanauki.pl/articles/1825988.pdf
Data publikacji:
2008
Wydawca:
Politechnika Koszalińska. Wydawnictwo Uczelniane
Tematy:
oczyszczanie ścieków miejskich
zanieczyszczenia tłuszczowe
oczyszczalnia ścieków
usuwanie substancji tłuszczowych
Opis:
Development of civilization brought about the excessive amounts of grease in certain places, like in case of other compounds essential in biosphere, what is the reason of disadvantageous phenomena in natural environment. The significant source of grease substances is wastewater. The wastewater treatment standards worked out in the past do not assure the appropriate protection of wastewater receivers from excessive inflow of grease substances. Regarding this fact more attention should be paid to lipids removal in municipal sewage treatment plants, although Polish regulations do not force such action. Apart from influencing wastewater receivers fats and oils contained in raw wastewater stream cause technological disturbances and operational problems in the treatment plants. One of the most serious problems in activated sludge systems is rising sludge. For determination of grease and oil removal efficiency the mentioned substances content was analysed in raw and treated sewage streams, wastes and sludges from municipal sewage treatment plant with classical technological system. Grease and oil concentration was determined by Soxhlet extraction with petroleum ether. Obtained results show that average grease substances removal was 42.7%. The biggest loading of the substances was removed with primary sludge. Significant, but lower amounts of grease and oil were removed in waste activated sludge stream. Moreover 31.3% loss of grease and oil was found during the sludge treatment. Probably it was the effect of microbiological degradation in the digestion tank. It was also found that 50% of day loading of grease substances, introduced to sludge treatment line was returned with sludge waters to raw sewage inflow. The balance of obtained results shows there is no grease and oil degradation in wastewater treatment line. Too short hydraulic retention time of wastewater and activated sludge mixing in biological stage may be the reason. Probably only sorption of grease and oil on activated sludge flocks occurs and removal in waste activated sludge stream. Partial degradation occurs in sludge treatment facilities. Analyses carried out show the possibility of decrease of grease and oil substances content in municipal sewage treatment plant effluents through removal of that substances from sludge waters returning to sewage treatment line.
Źródło:
Rocznik Ochrona Środowiska; 2008, Tom 10; 481-489
1506-218X
Pojawia się w:
Rocznik Ochrona Środowiska
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Skuteczność usuwania zanieczyszczeń bakteriologicznych w procesach oczyszczania ścieków z zastosowaniem stawów biologicznych
Efficiency of bacteriological pollution removal in sewage treatment using biological ponds
Autorzy:
Budzińska, K.
Jurek, A.
Szejniuk, B.
Wroński, G.
Powiązania:
https://bibliotekanauki.pl/articles/1819435.pdf
Data publikacji:
2011
Wydawca:
Politechnika Koszalińska. Wydawnictwo Uczelniane
Tematy:
oczyszczanie ścieków
zanieczyszczenia bakteriologiczne
stawy biologiczne
wastewater treatment
bacteriological contamination
bioponds
Opis:
Jednym z etapów oczyszczania ścieków jest proces biologiczny, który stosuje się gdy metody zastosowane wcześniej nie zapewniają odpowiedniej klasy czystości wody zrzucanej do odbiorników. Istotną funkcję w tych przemianach stanowi działalność metaboliczna mikroorganizmów, które warunkują rozkład substancji organicznych. Technologie biologicznego oczyszczania ścieków stworzone są przez człowieka, jednakże opierają się głównie na procesach naturalnych. Zasada oczyszczania jest taka sama, jak w przypadku naturalnego samooczyszczania się zbiorników wodnych, przy czym różnica polega na stworzeniu optymalnych warunków usuwania zanieczyszczeń ze ścieków (obecność tlenu, pożywki, mieszanie mechaniczne, temperatura, pH, itp.), które zwiększają szybkość i skuteczność procesu [11]. Jedną z metod biologicznego oczyszczania ścieków jest wykorzystanie stawów ściekowych.
The subject of this study was household sewage from treatment plant working in biological ponds technology (aerated and stabilized), located in the kujawsko-pomorskie province. The study involved assessment of sewage treatment efficacy through the analysis of indicator bacteria elimination at particular stages of treatment processes. Raw sewage, after mechanical treatment in two stabilization ponds and after sand filters were examined. Sewage samples were collected according to the instruction of sampling, handling and storage given in EN 25667-2 and PN-EN ISO 5667-3. Analyses of collected sewage were made 7 times in the autumn-winter and spring-summer periods. The number of bacteria of the Enterobacteriaceae family, Escherichia coli, fecal streptococci and presence of microorganisms of Salmonella genus were determined in sewage. Carried out analyses show that the most numerous group of microorganisms occurring in raw sewage were bacteria of the Enterobacteriaceae family, which number was from 106 to 108 cells .ml-1. Raw sewage was also characterized by occurrence of a very large number of Escherichia coli (107 cells in 1 ml). Fecal streptococci constituted the least numerous group of bacteria determined in sewage. Number of those microorganisms ranged from 104 to 105 cells in 1 ml of raw sewage. The study indicated the presence of bacilli of the Salmonella genus in 70% of analyzed samples. Mechanical sewage treatment contributed to elimination of indicator bacteria, and the least percentage of reduction was observed in the case of fecal streptococci (48.5%), while the highest to bacteria of the Enterobacteriaceae family (85.5%). Bacteria Escherichia coli were reduced in 63.6%. Sewage treatment in stabilization ponds allowed a considerable decrease in the number of determined bacteria, which elimination level was within the range 98%-99%, whereas streptococci were removed in least effective way at this stage of treatment. Sewage treated on sand filters - discharged to the river Drweca - were characterized by the occurrence of indicator bacteria at a level of 102 cells/ml, in spite of obtaining a high reduction level of those bacteria, which amounted to 99.99%. In treated sewage, bacteria of the Enterobac-teriaceae family, constituted the largest group and Escherichia coli occurred in the smallest amounts. The number of other fecal bacteria and enterobacteria indicates a possibility of occurrence of pathogenic microorganisms in sewage discharged to surface waters. The fact of bacilli of the Salmonella genus occurring in treated sewage (10% of sewage samples) is particularly alarming. This creates a potential risk of pollution of the natural environment.
Źródło:
Rocznik Ochrona Środowiska; 2011, Tom 13; 1519-1530
1506-218X
Pojawia się w:
Rocznik Ochrona Środowiska
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Analiza zmian udziału frakcji ChZT w procesie denitryfikacji z zewnętrznym źródłem węgla
Analysis of COD Fractions Changes During Denitrification Process with External Carbon Source
Autorzy:
Smyk, J.
Ignatowicz, K.
Piekarski, J.
Powiązania:
https://bibliotekanauki.pl/articles/1813840.pdf
Data publikacji:
2017
Wydawca:
Politechnika Koszalińska. Wydawnictwo Uczelniane
Tematy:
oczyszczanie ścieków
frakcje ChZT
zanieczyszczenia biodegradowalne
zanieczyszczenia niebiodegradowalne
denitryfikacja
zewnętrze źródła węgla
wastewater treatment
COD fractions
pollution biodegradable
denitrification
external carbon source
Opis:
W artykule przedstawiono wyniki badań dotyczące stężeń frakcji ChZT w mechaniczno-biologicznej oczyszczalni ścieków o wielkości >1000 000 RLM, zlokalizowanej w Białymstoku. Dodatkowo oznaczono BZT5, azot amonowy, azotany (V), azot ogólny oraz fosfor ogólny. Analizowano próbki ścieków surowych, z komory predenityfikacji, komory defosfatacji, komory denitryfikacji w miejscu dawkowania zewnętrznego źródła węgla - Brenntaplus VP1, komory denitryfikacji w pewnej odległości od miejsca dawkowania zewnętrznego źródłem węgla oraz ścieki oczyszczone. Metodyka wyznaczania stężeń frakcji ChZT została opracowana na podstawie wytycznej ATV-131. Podczas wykonywania analizy określono następujące frakcje: nierozpuszczalnej materii organicznej, biologicznie wolno rozkładalnej (XS), rozpuszczonej materii organicznej, biologicznie łatwo rozkładalnej, (SS), nierozpuszczalnej materii organicznej, biologicznie trudno rozkładalnej (XI) i rozpuszczonej materii organiczne, biologicznie nierozkładalnej (SI). Przeprowadzona analiza pokazała, że w ściekach surowych doprowadzanych do oczyszczalni ścieków ponad 80% materii organicznej określanej jako ChZT stanowiły frakcje biologicznie rozkładalne XS i SS. Niskie stężenie udziału procentowego materii organicznej we frakcji SS oraz XS w ściekach oczyszczonych świadczy o przyswajaniu tych frakcji przez mikroorganizmy biorące udział w procesach usuwania związków azotu i fosforu. Niskie stężenie i procentowy udział materii organicznej we frakcji ChZT nierozpuszczalnej nierozkładalnej XI w ściekach oczyszczonych świadczy o wbudowywaniu jej w kłaczki osadu czynnego. Układ technologiczny oczyszczania ścieków analizowanej oczyszczalni nie miał wpływu na zmianę stężenia rozpuszczonej frakcji biologicznie nierozkładalnej SI w ściekach. Niskie stężenie azotanów (V) w ściekach oczyszczonych zostało uzyskane z powodu dawkowania zewnętrznego źródła węgla. Usuwanie zanieczyszczeń w oczyszczalni ścieków w Białymstoku przebiega prawidłowo i jest zgodne z polskimi regulacjami prawnymi.
The article presents results of analysis on concentration of COD fractions in mechanical-biological treatment plant with a size > 1000 000 RLM, located in Bialystok. Additionally determined BOD5, ammonia nitrogen, nitrates (v), total nitrogen and total phosphorus. The samples were tested: raw sewage, from the chamber pre-denitrification, from chamber of phosphorus removal, from the denitrification chamber in place of the dosage of external carbon source - Brenntaplus VP1, from the denitrification chamber at a distance from the place of dosing external carbon source and samples of treated sewage. Methodology for determining the fraction of COD was developed based on the guidelines of ATV-131. During the studyidentified the followingfractions: SS – COD of soluble organic easily biodegradable substances, SI – COD of soluble organic non-biodegradable substances, XS – COD of organic slowly biodegradable suspensions, XI – COD of organic non-biodegradable suspensions. Based on the study was formed the following conclusions that in raw wastewater, the dominating percent-age was recorded for fractions of biodegrad-able contaminants (SS and XS) reaching about 80% of the total COD of sewage. Low share content of organic matter in the fraction of SS and XS treated wastewater shows the absorption of these fractions by the microorganisms involved in processes for the removal of nitrogen and phosphorus. Low content of quantitative and percentage of organic compounds in the fraction of undissolved COD irreducible XI in treated wastewater, testifies to its incorporation in activated sludge floc. The technological system of wastewater treatment plant does not change the concentration of the dissolved fraction in the wastewater biologically decomposable SI. Low concentration of nitrates (V) in the treated wastewater was obtained by dosing an external source of carbon. Removal of pollutants in waste watertreatment plant in Bialystok is correct and is in line with the requirements of Polish law.
Źródło:
Rocznik Ochrona Środowiska; 2017, Tom 19; 760-776
1506-218X
Pojawia się w:
Rocznik Ochrona Środowiska
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Wpływ obciążenia osadu ładunkiem zanieczyszczeń organicznych na wzrost wybranych grup bakterii podczas procesu oczyszczania odcieków ze składowiska odpadów w SBR 443
Influence of Sludge Loading with Contaminants on the Growth of Selected Groups of Bacteria During Landfill Leachate Pretreatment in SBR
Autorzy:
Szyłak-Szydłowski, M.
Grabińska-Łoniewska, A.
Powiązania:
https://bibliotekanauki.pl/articles/1825993.pdf
Data publikacji:
2008
Wydawca:
Politechnika Koszalińska. Wydawnictwo Uczelniane
Tematy:
zanieczyszczenia mikrobiologiczne
biologiczne oczyszczanie ścieków
osad czynny
bakterie
bakterie psychrofilne
HBP
bakterie sporowe
bakterie mezofilne
bakterie coli
Opis:
Celem badań bakteriologicznych było określenie wpływu obciążenia osadu czynnego ładunkiem zanieczyszczeń organicznych (Bx) na rozwój w nim wybranych grup bakterii będących wskaźnikami stopnia rozkładu związków organicznych i zanieczyszczenia pod względem sanitarnym. Założeniem tych badań było ustalenie zakresu Bx, przy którym zachodzi eliminacja tych bakterii z odcieków połączona z ich akumulacją w kłaczkach osadu oraz oszacowanie stopnia zagrożenia sanitarnego dla środowiska przy jego ewentualnym wykorzystaniu do celów rolniczych. Wskaźnikami stopnia rozkładu zanieczyszczeń organicznych występujących w odciekach, była ogólna liczba heterotroficznych bakterii psychrofilnych (HBP) i bakterii sporowych (BS), a zanieczyszczenia pod względem sanitarnym: bakterie mezofilne (BM), bakterie z rodziny Enterobacteriaceae, termotolerancyjne bakterie grupy coli (TBGC) oraz Clostridium perfringens.
Assessment of the influence of activated sludge loading with organic contaminants (Bx) on the development in it of selected groups of bacteria, which are indexes of decomposition degree of organic compounds and sanitary contamination, was the aim of conducted biological investigations. Determination of Bx range, in which elimination from leachate of those bacteria connected with their accumulation in floccules of activated sludge takes place as well as estimation of level of sanitary threat for the environment when it is used in agriculture were aims was of these investigations. Indexes of degree of organic contaminants decomposition occurring in leachates were: general number of heterotrophic psychrophilic bacteria (HBP) and sporeforming bacteria (BS), and sanitary contamination were: mesophilic bacteria (BM), bacteria from Enterobacteriaceae family, thermotolerant bacteria of cola group (TBGC) and Clostridium perfringens. Leachate used in investigations were piped off with drainage system to cumulative well located near landfill of wastes other than inert and dangerous, so-called municipal situated in the south-east part of Otwock city. Landfill functions from 1998 and the planned end of exploitation is anticipated in the year 2012. Municipal wastes in the quantity over 20 Mg per day are deposited in it. Dominating group of bacteria both in leachates and activated sludge adapted to their pretreatment constituted heterotrophic psychrophilic (HPB) and mesophilic bacteria (MB). Less numerous were sporeforming bacteria (BS) and the bacteria from the class Enterobacteriaceae. The greatly lower numbers of thermotolerant coliform bacteria (TCB) and Cl. perfringens were stated. Among the studied groups of bacteria - HPB, BM, TCB and bacteria from class Enterobacteriaceae showed the most stable growth in activated sludge. The washing out of these bacteria occurred at the maximal studied Bx = 1.64 mgCOD mg-1 d-1. Less stable growth characterized Cl. perfringens (washing out at Bx = 0.96 mgCOD mg-1 d-1). Fast washing out of SB (Bx = 0.34 mgCOD mg-1 d-1) took place. The number of these groups of bacteria in activated sludge and effluent from SBR don't constitute a sanitary impedence for environment. Conducted investigations allow to state, that both leachates outflowing from SBR as well as excessive activated sludge coming into being in the process of treatment, taking into consideration size of investigated bacteria groups does not make up sanitary threat for the environment. However full distinguishing in this issue may be made just after executing investigations on occurrence and size in those biotopes of bacteria and microscopic fungi pathogenic for warm-blooded animals and human.
Źródło:
Rocznik Ochrona Środowiska; 2008, Tom 10; 443-456
1506-218X
Pojawia się w:
Rocznik Ochrona Środowiska
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-6 z 6

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies