Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "biological wastewater" wg kryterium: Temat


Wyświetlanie 1-6 z 6
Tytuł:
Efektywność oczyszczania ścieków przy zastosowaniu reaktora membranowego
Effectiveness of Wastewater Treatment with the Use of the Biological Membrane Reactors
Autorzy:
Konieczny, K.
Powiązania:
https://bibliotekanauki.pl/articles/1818639.pdf
Data publikacji:
2015
Wydawca:
Politechnika Koszalińska. Wydawnictwo Uczelniane
Tematy:
biologiczne oczyszczanie ścieków
ultrafiltracja
biologiczne reaktory membranowe (MBR)
biological wastewater treatment
ultrafiltration
membrane biological reactors (MBR)
Opis:
The paper compares the effectiveness of MBR reactor working on the pitot scale in the COŚ sewage treatment plant (No 1) with MBR in treatment plant ZOŚ (No 2) working on the full technical scale. In the COŚ wastewater treatment plant reactor was working in hybrid system: biological reactor with classical treatment - ultrafiltration (RM). It was compared the purification effectiveness of the classical biological reactor with secondary settling tank (RB), with purification effects obtained using membrane module (RM) fulfilling the role of secondary settling tank. Membrane installation BIO-CEL®-BC 10 type has been placed outside the activated sludge reactor. In the study the PES membrane (area 10 m2), made by the German company Microdyn-Nadir GmbH, has been used. In the first stage of the work, the results of physico-chemical analyses for raw and purified sewage for both systems, has been presented. The following pollutants indexes were determined: chemical oxygen demand (COD), biochemical oxygen demand (BOD5), the concentration of total nitrogen (Nog), the concentration of total phosphorus (Pog), suspension content, turbidity and conductivity at 25°C. In addition, for the determination of the filtration effectiveness, microbiological tests were carried out to check if permeate can poses a threat in terms of people heath. In the second part of the publication, the preliminary results of effectiveness of the wastewater treatment for the full technical scale in the sewage treatment plant ZOŚ (No 2) have been presented. For small bulk treatment plant with biological membrane reactors (MBR), exploitation conditions are given. Analyzed treatment plant, as a result of modernization, consists of a compact device for mechanical wastewater treatment and activated sludge reactor. Biological reactor applied PES ultrafiltration membranes made, as in the case COŚ, by Microdyn-Nadir GmbH. Membrane module fulfilled the same role as the classic secondary clarifier and served to separate purified wastewater from activated sludge. Analysis of wastewater quality confirmed high removal efficiency of organic pollutants (an average of 99% for BOD5 and above 97% for COD) and suspended solids (average 99%) in the studied sewage treatment plant. Comparing the efficiency of wastewater treatment in COŚ and ZOŚ sewage treatment plants, in which MBR has been installed, respectively in the pilot and full technical scale, removal degree of impurities was very high, in the range of 93–99%. The level of contaminants in both tested plants was similar. Obtained very high removal degrees of all determined pollutants, were definitely higher than that obtained in the classical biological treatment plants and definitely higher than the requirements given in regulation of the Environmental Minister [13]. An important achievement resulting from the research in COŚ treatment plant, supported by the results, is statement that permeates quality largely depends on the amount of oxygen delivered to the activated sludge tank and to the tank with membrane module. The best results were obtained for MBR system working in the continuous mode.
Źródło:
Rocznik Ochrona Środowiska; 2015, Tom 17, cz. 2; 1034-1052
1506-218X
Pojawia się w:
Rocznik Ochrona Środowiska
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Dobór parametrów konstrukcyjnych rotacyjnego złoża biologicznego metodą znacznikową
The Selection of Design Parameters of the Rotating Biological Contactor Using Tracer Studies
Autorzy:
Szulżyk-Cieplak, J.
Duda, A.
Lenik, K.
Powiązania:
https://bibliotekanauki.pl/articles/1818075.pdf
Data publikacji:
2016
Wydawca:
Politechnika Koszalińska. Wydawnictwo Uczelniane
Tematy:
biologiczne złoże obrotowe
ścieki bytowe
biologiczne oczyszczanie ścieków
rotating biological contactor (RBC)
domestic sewage
biological wastewater treatment
Opis:
The subject of research consists in a rotational biological contactor with a rotor characterized by a bi-directional longitudinal flow as an element of synchronized system of disposal and biological treatment of sanitary wastewater in small-bore sewerage. The rotor design is based on a system of corrugated protective pipes, arranged in coils wound around its rotation axis. The corrugated pipes have two purposes. On the one hand, they ensure and enable the aeration of activated sludge, and provide the surface for biofilm development on the other. The special winding of corrugated pipes enables a bi-directional flow of the liquid medium. During the rotation of the rotor, the RBC is simultaneously emptied and filled with wastewater. The structure of the rotational biological contactor aims to provide intensive aeration of the transported wastewater, which would allow for a greater development of microorganisms participating in the hybrid treatment of wastewater, i.e. the activated sludge method and by means of a trickling filter. Design solutions of the rotor pertaining to coil arrangement and the drive system were analyzed and tracer studies of hydrodynamics were performed in regard to the selection of appropriate structural parameters of the device. The obtained results indicate a clear influence of the design solution and its kinematics on the aeration time of the flowing medium, which is one of the parameters governing the efficiency and quality of RBC operation.
Źródło:
Rocznik Ochrona Środowiska; 2016, Tom 18, cz. 2; 897-908
1506-218X
Pojawia się w:
Rocznik Ochrona Środowiska
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Anaerobic Ciliates in Activated Sludge Communities
Orzęski anaerobowe w osadzie czynnym
Autorzy:
Babko, R.
Kuzmina, T.
Pliashechnik, V.
Łagód, G.
Fyda, J.
Powiązania:
https://bibliotekanauki.pl/articles/1818050.pdf
Data publikacji:
2016
Wydawca:
Politechnika Koszalińska. Wydawnictwo Uczelniane
Tematy:
anaerobic ciliates
activated sludge
biological wastewater treatment
orzęski anaerobowe
osad czynny
biologiczne oczyszczanie ścieków
Opis:
Występowanie wielu gatunków orzęsków beztlenowych w osadzie czynnym oczyszczalni ścieków pracujących w warunkach aerobowych było do tej pory stosunkowo rzadkie. W przypadku orzęsków beztlenowych, ich obecność traktowano jako sygnał informujący o pogorszeniu jakości osadu czynnego lub występowanie sytuacji zagrożenia dla tlenowego procesu biologicznego oczyszczania ścieków. Rozwój technologii biologicznego oczyszczania ścieków w celu zapewnienia skutecznego usuwania związków węgla, azotu oraz fosforu, doprowadził do uruchomienia nowej generacji oczyszczalni z bioreaktorami pracującymi w naprzemiennych warunkach beztlenowych, niedotlenionych i tlenowych. Wraz ze zmianą technologii powstaje pytanie co do konieczności zmian w rozumieniu i interpretacji miejsca i znaczenia orzęsków anaerobowych w zespołach osadu czynnego oraz ich roli jako indykatorów procesów oczyszczania ścieków. Regularne występowanie w osadzie czynnym, pochodzącym ze zmodyfikowanych oczyszczalni, obligatoryjnych lub fakultatywnych gatunków orzęsków anaerobowych, może być ważnym wskaźnikiem bilansu oraz zrównoważenia kolejnych faz procesu oczyszczania ścieków. W oparciu o przeprowadzone badania osadu czynnego z 15 oczyszczalni zlokalizowanych w Polsce można stwierdzić, że częstotliwość występowania orzęsków anaerobowych jest niska. W sumie zidentyfikowano 10 obligatoryjnych i fakultatywnych gatunków anaerobowych. W zmieniających się warunkach tlenowych/ anoksycznych /anaerobowych najczęściej obserwowane były H. discolor, A. uncinata, A. cicada, C. polypinum, E. coronata, L. lamella, P. rouxi, V. aquadulcis, P. elongatа. Rozwój badań w zakresie ekologii orzęsków anaerobowych, występujących w oczyszczalniach ścieków oraz w różnych systemach laboratoryjnych, pozwoli rozszerzyć możliwości interpretacji ich roli podczas oczyszczania ścieków metodą osadu czynnego oraz określić ich potencjał jako indykatorów odnośnie występujących warunków procesowych w nowoczesnych oczyszczalniach do zintegrowanego usuwania węgla azotu i fosforu.
Źródło:
Rocznik Ochrona Środowiska; 2016, Tom 18, cz. 2; 733-745
1506-218X
Pojawia się w:
Rocznik Ochrona Środowiska
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Frakcje ChZT ścieków w mechaniczno-biologicznej oczyszczalni
COD Fractions in mechanical-biological wastewater treatment plant
Autorzy:
Sadecka, Z.
Płuciennik-Koropczuk, E.
Powiązania:
https://bibliotekanauki.pl/articles/1819509.pdf
Data publikacji:
2011
Wydawca:
Politechnika Koszalińska. Wydawnictwo Uczelniane
Tematy:
oczyszczalnie ścieków
oczyszczalnie mechaniczne
oczyszczalnie biologiczne
frakcje ChZT
sewage treatment plants
mechanical treatment
biological wastewater
COD fractions
Opis:
W pracy przeprowadzono ocenę skuteczności rozkładu zanieczyszczeń organicznych w ściekach po poszczególnych procesach mechaniczno-biologicznego oczyszczania ze szczególnym uwzględnieniem zmian frakcji ChZT w ciągu technologicznym oczyszczalni w Zielonej Górze.
In Polish literature there is little information regarding the distribution of COD fractions, therefore, identify the theoretical topic has been mainly based on foreign literature. Literature data 'tips a COD divided into factions as the most suitable for accurate characterization of organic matter in municipal wastewater. In Poland, continues for many years, to identify the organic matter in wastewater contractual indicators such as BOD5, CODCr, CODMn, organic carbon content and loss during roasting were used. Information on the composition of the effluent, obtained based on these conventional indicators, are much less accurate when compared with data obtained on the basis of COD fractions. In the majority of cases the values of concentration of biodegradable organic matter in wastewater is expressed in BOD5, whereas identification of COD fractions, additionally allows the evaluation of the amount of impurities which are non biodegradable and which decrease the efficiency of biological treatment. The paper presents results of studies concerning the designation of COD fraction in the raw wastewater and their alternations after subsequent processes in mechanical-biological wastewater treatment. The test object was a wastewater treatment plant for the city of Zielona Góra. Sampling of raw wastewater and wastewater after various stages of mechanical-biological treatment, and laboratory tests such as designating pollution indicators such as: CODMn, CODCr, BOD5, BODtot and TOC was performed according to Polish standards. During investigation following fractions of COD were also determined: dissolved non bioderadable SI, dissolved easily biodegradable SS, in organic suspension slowly degradable XS and in organic suspension non-biodegradable XI. Methodology for determining the COD fraction was based on the guidelines ATV A 131. Analysis of results of research concerning changes in fractions of COD in the wastewater treatment plant showed that: 1. More than 75% of the total COD in the raw wastewater inflowing to the wastewater treatment plant "Łącza" were biodegradable fractions: bound in suspension XS and dissolved SS, 2. Technological system of the mechanical-biological wastewater treatment plant in Zielona Góra does not change the solute concentration in the effluent of non-biodegradable dissolved fraction SI, 3. Changes in the percentage contribution of fraction XS, XI, and the SS were a consequence of biochemical changes occurring in the biological part of the plant, 4. CODCr indicator values in all analyzed wastewater samples were lower than the total COD, which is the sum of individual fractions of COD, 5. Differences between the effectiveness of work in the wastewater treatment plant in Zielona Góra based on CODCr and total COD were the order of 1%, 6. The values of the percentage contribution of XS, XI, SI, and SS fraction in the total COD of raw wastewater from Zielona Góra are consistent with the values given in the literature.
Źródło:
Rocznik Ochrona Środowiska; 2011, Tom 13; 1157-1172
1506-218X
Pojawia się w:
Rocznik Ochrona Środowiska
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Wspomaganie procesu denitryfikacji preparatem Brenntaplus VP1 jako zewnętrznym źródłem węgla
Intensification of the Denitrification Process by Using Brenntaplus VP1 Preparation
Autorzy:
Ignatowicz, K.
Piekarski, J.
Kozłowski, D.
Powiązania:
https://bibliotekanauki.pl/articles/1818612.pdf
Data publikacji:
2015
Wydawca:
Politechnika Koszalińska. Wydawnictwo Uczelniane
Tematy:
ścieki
biologiczne oczyszczanie
denitryfikacja
zewnętrzne źródło węgla
wastewater
biological treatment
denitrification
external carbon source
Opis:
The object of the study presented by authors was wastewater treatment plant (W.W.T.P.) in Bialystok. This plant started to operate with aerobic sludge activated system nearly 18 years ago and now it is utilizing high efficiency system for C, N, and P removal from municipal wastewater. Flow capacity is about 70000 m3 per day. Nitrogen and phosphorus contained in treated wastewater are responsible for eutrophication process. High efficiency of its removal is very important to protect the environment. Improvement of denitrification process can be realized by using external source of carbon. To confirm usefulness and efficiency of Brenntaplus VP as an external source of carbon the cycle of research was performed in Bialystok municipal W.W.T.P. Brenntaplus VP is based on alcohol, sugar and proteins. It is safe and completely biodegradable. The process of dosing preparation is continued all year without period with temperature lower than 12°C. Research was performed from mid April till the end of October 2011. Results shown in this paper were obtained in October 2011. Samples were taken from pre-denitrification, phosphorus removal, denitrification and nitrification chambers. It was found that BOD5/COD ratio was 1,86 in raw wastewater. The study confirmed the positive impact of Brenntaplus VP1 on denitrification process. External carbon source increases the amount of nitrogen removed from wastewater and allows to achieve nitrogen concentration in the treated wastewater below 10 mg N/dm3. Final concentration of nitrogen was dependent with wastewater temperature. Obtained results also proved short adaptation time for activated sludge with Brenntaplus VP1.
Źródło:
Rocznik Ochrona Środowiska; 2015, Tom 17, cz. 2; 1178-1195
1506-218X
Pojawia się w:
Rocznik Ochrona Środowiska
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Zastosowanie procesu Fentona i sekwencyjnych reaktorów porcjowanych do oczyszczania ścieków z produkcji okien drewnianych
Application of fentons process and sequencing batch reactors for treatment of wastewater from wood windows manufacture
Autorzy:
Piaskowski, K.
Świderska-Dąbrowska, R.
Powiązania:
https://bibliotekanauki.pl/articles/1819655.pdf
Data publikacji:
2010
Wydawca:
Politechnika Koszalińska. Wydawnictwo Uczelniane
Tematy:
proces Fentona
reaktor biologiczny
oczyszczanie ścieków produkcyjnych
produkcja okien
Fenton process
biological reactor
treatment of wastewater production
production of windows
Opis:
Przeprowadzone badania nad oczyszczaniem ścieków klejowych po procesie Fentona z neutralizacją w reaktorze SBR pozwoliły na sformułowanie następujących wniosków: 1. Ścieki klejowe po procesie Fentona nie wykazywały negatywnego oddziaływania bezpośrednio na aktywność osadu czynnego w SBR, poprawiały natomiast właściwości sedymentacyjne kłaczków osadu. 2. Dozowanie ścieków klejowych po procesie Fentona z neutralizacjązwiększały pH do 8 oraz przewodność właściwą ścieków oczyszczonych, będącą pozostałością katalizatora procesu utleniania. 3. Wzrost ładunku węgla organicznego w reaktorze eksperymentalnym intensyfikował biologiczne usuwanie ortofosforanów, jednocześnie obniżając usuwanie związków azotu w procesie nitryfikacji. 4. Pomimo zastosowania chemicznego utleniania odczynnikiem Fentona, część węgla organicznego nie podlegała biodegradacji i kumulowała się w reaktorze, zwiększając stężenie OWO w ściekach oczyszczonych.5. Usunięcie węgla organicznego ze ścieków klejowych uzyskano w okresie prowadzonych badań na poziomie 44,8÷71,3%. 6. Wraz ze wzrostem obciążenia osadu ładunkiem organicznym od 53,3 do 398,5 mgC/gosźd, rosło jednostkowe usunięcie węgla organicznego od 23,9 do 284,1 mgC/gosźd.
The advanced oxidation process with Fenton's reagent can be used in industrial wastewater treatment, especially in the degradation of not easily biodegradable contaminations. Chemical oxidation of industrial wastewater or other substances as a pre-treatment before biological treatment is the most effective method of wastewater treatment. However, besides many advantages, the method has some restrictions: it requires low-pH (2-4) of wastewater and final neutralisation has to be performed, production of great amounts of iron-containing sediment. This paper presents laboratory experiments on treatment of adhesive wastewater in an SBR reactor after the Fenton process, with neutralisation at the end. The experiment sought to determine the effect of that purification system on the state of the activated sludge, the course of biological processes (nitrogen and phosphorus removal) and the effectiveness of wastewater treatment.The study was conducted on the test stand, which scheme is shown in Figure 1. This stand consisted of two sequential batch reactors SBR with working capacity of 3 liters. In such configuration SBR-1 reactor was the control reactor, while, in addition to the other one chemical wastewater after the Fenton process were added (SBR-2). The research was carried out on wastewater from the company producing of windows and doors. Wastewater come from washing and rinsing of adhesive installations. Adhesive wastewater after Fenton's process showed no negative impact directly on the activity of activated sludge in SBR, improving the sedimentary characteristics of sludge floes. Dosing of adhesive wastewater after Fenton's process with neutralisation increased the pH to 8, and the conductivity of the treated wastewater, which is a remnant of a catalyst for oxidation process. The increase of organic carbon load in the experimental reactor intensified biological removal of orthophosphates, while decreasing removal of nitrogen compounds in the process of nitrification. Despite application of chemical oxidation with Fenton's reagent, part of organic carbon was not subject to biodégradation and cumulated in the reactor, increasing the concentration of TOC in treated wastewater. Removal of organic carbon from adhesive wastewater obtained during research period was 44.8-71.3%. With the increase of sludge loading with organic load from 53.3 to 398.5 mgC/g0S-d, the unit removal of organic carbon increased from 23.9 to 284.1 mgC/g0S-d.
Źródło:
Rocznik Ochrona Środowiska; 2010, Tom 12; 503-523
1506-218X
Pojawia się w:
Rocznik Ochrona Środowiska
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-6 z 6

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies