Tytuł:
Charakterystyka zagrożeń biologicznych występujących przy przetwarzaniu biomasy do celów energetycznych
Characteristics of Biological Hazards Associated with Processing of Biomass for Energy Purposes
Autorzy:
Gołofit-Szymczak, M.
Ławniczek-Wałczyk, A.
Górny, R. L.
Cyprowski, M.
Stobnicka, A.
Powiązania:
https://bibliotekanauki.pl/articles/1818071.pdf
Data publikacji:
2016
Wydawca:
Politechnika Koszalińska. Wydawnictwo Uczelniane
Tematy:
narażenie zawodowe
biomasa
bioaerozol
occupational exposure
biomass
bioaerosol
Opis:
One of the main biohazard for the employees working in processing of biomass for energy purposes is organic dust. The bioaerosol sampling was carried out at two power plants and three combined heat and power plants in Poland which co-combusted the agricultural and forest biomass with coal dust. The bacterial and fungal aerosol was collected stationary by a single-stage MAS-100 impactor. Fourteen different types of biomass samples used in the co-combustion process were also analyzed: conifer chips, alder chips, bark, sawdust, sunflower hull pellet, olive pellet, straw pellet, oat hull pellet, biofuel mix pellet, olive pomace, straw waste, corn pomace, dried fruit and straw with coal. The concentrations of bacterial and fungal aerosol ranged from 0.9×103 to 2.3×106 CFU/m3 and from 0.2×103 to 1.5×105 CFU/m3, respectively. The highest concentrations of bacterial and fungal aerosols were determined at workplaces related to screening, reloading and biomass transport via conveyor belts. The most prevalent in the air were fungi from Aspergillus genus and Gram-negative rods. Bacterial and fungal concentrations in biomass samples ranged from 1.8×103 CFU/g to 3.9×106 CFU/g and from 0.1×103 CFU/g to 22.7×106 CFU/g, respectively. Their highest concentrations were recorded in the samples of straw mixed with coal. This study showed that employees working at a power plant, both in the technological lines and in the laboratories, are associated with the exposure to high concentrations of potentially pathogenic microorganisms. Hence, to reduce such exposure, both hermetization of biomass processing and regular control of work environment should be applied.
Źródło:
Rocznik Ochrona Środowiska; 2016, Tom 18, cz. 2; 193-204
1506-218X
Pojawia się w:
Rocznik Ochrona Środowiska
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Mikrobiologiczna jakość powietrza w klimatyzowanych samochodach osobowych
Microbial Air Quality in Air-conditioned Passenger Cars
Autorzy:
Gołofit-Szymczak, M.
Stobnicka-Kupiec, A.
Powiązania:
https://bibliotekanauki.pl/articles/1813746.pdf
Data publikacji:
2018
Wydawca:
Politechnika Koszalińska. Wydawnictwo Uczelniane
Tematy:
samochody
system klimatyzacyjny
bioaerozol
cars
air-conditioning system
bioaerosol
Opis:
Transport drogowy jest najbardziej powszechnym środkiem komunikacyjnym na świecie. W celu zwiększenia komfortu użytkowania, samochody wyposażane są w instalacje klimatyzacyjne. Systemy klimatyzacji samochodowej mogą być źródłem skażenia mikrobiologicznego wnętrza pojazdów. Celem niniejszego projektu była ocena poziomu mikrobiologicznego zanieczyszczenia powietrza w samochodach osobowych. Badanie przeprowadzono w 35 losowo wybranych samochodach osobowych wyposażonych w układ klimatyzacji. Próbki bioaerozolu zostały pobrane przy użyciu 6-stopniowego impaktora Andersena. Do celu pobierania próbek aerozoli bakteryjnego i grzybowego stosowano standardowe szalki Petriego wypełnione, odpowiednio agarem tryptozowo-sojowy z 5% dodatkiem odwłóknionej krwi baraniej oraz agarem słodowy. Wszystkie mikroorganizmy wyizolowane z próbek powietrza były analizowane ilościowo i jakościowo (do poziomu rodzaju i / lub gatunku). Badanie wykazało, że powietrze w samochodach wyposażonych w instalacje klimatyzacyjne jest zanieczyszczone mikrobiologicznie. Stężenie bakterii i grzybów w próbkach powietrza pobranych we wnętrzu kabin samochodów osobowych wynosiło odpowiednio 6,2·102 jtk/m3 i 2,2·102 jtk/m3. Na podstawie wyników badań stwierdzono, że liczba przejechanych kilometrów znacząco determinuje obserwowane stężenia aerozoli bakteryjnych i grzybowych, natomiast rodzaj klimatyzacji i rodzaj tapicerki nie wpływają istotnie na obserwowane stężenia bioaerozoli w badanych pojazdach. Wraz ze wzrostem liczby przejechanych kilometrów zaobserwowano zwiększenia stężenia aerozoli bakteryjnych i grzybowych w badanych pojazdach. Zastosowanie sześciostopniowego impaktora Andersena pozwoliło uzyskać dane o rozkładzie ziarnowym cząstek aerozoli w badanych samochodach osobowych. Analiza rozkładu ziarnowego bioaerozoli wykazała, że mikroorganizmy były obecne w powietrzu głównie jako pojedyncze komórki i duże agregaty. Na podstawie danych o wielkości cząstek aerozoli bakteryjnych i grzybowych oraz ich potencjalnej depozycji w układzie oddechowym człowieka, można stwierdzić, że bioaerozole obecne w badanych pojazdach, penetrując ludzki układ oddechowy, mogą osadzać się w jamie ustnej i nosowej, w tchawicy, oskrzelach i oskrzelikach płucnych. Może to być przyczyną podrażnienie nosa i gardła, reakcji astmatycznej lub reakcji w postaci alergicznego zapalenia. Analiza jakościowa mikroorganizmów izolowanych z powietrza badanych samochodów wykazała dominację ziarniaków Gram-dodatnich z rodzajów Staphylococcus, Micrococcus i Kocuria, przetrwalnikujących laseczek z rodzaju Bacillus oraz grzybów pleśniowych z rodzajów Acremonium, Alternaria, Penicillium, Aspergillus i Cladosporium.
The road transport is the most common means of communication in the world. To improve the comfort, the cars are equipped with air conditioning installation. Automobile air-conditioning systems (AC) may be a source of microbiological contamination of driver’s cabs. The aim of this study was to assessment the level of microbial contamination inside passenger cars. The study was carried out in 35 randomly selected cars equipped with climate control system. The viable (culturable) bioaerosol samples was stationery taken using 6-stage Andersen impactor. Standard Petri dishes filled with blood trypticase soy agar and malt extract agar were used for bacterial and fungal sampling, respectively. All microorganisms isolated from air samples were quantitatively and qualitatively (to genus and/or species level) analyzed. The bacterial and fungal concentrations in air samples were between 6,2·102 cfu/m3 and 2,2·102 cfu/m3, respectively. Based on the results of this study, it was found that mileage significantly determined the observed concentrations of bacterial and fungal aerosols while the type of air conditioning and the type of upholstery did not significantly determine the observed concentrations of bioaerosols in the studied vehicles. As the number of miles traveled, the increased of concentration of bacterial and fungal aerosols in the tested vehicles were observed. The use of the 6-stage Andersen impactor in this study allowed for obtaining data on the particle size distribution of aerosols in the studied cars. The size distribution analysis revealed that microorganisms were present in the air mainly as single cells and large aggregates. Based on results the size and distribution of bioaerosol particles, it can be ascertain that bioaerosols present in the studied cars, penetrating the human respiratory tract, may be deposited within the oral and nasal cavities, trachea, secondary bronchi and bronchioles and, by that, may be responsible for nose and eye irritations, asthmatic reactions, and allergic inflammations. The most prevalent bacterial species in the air of car cabins were Gram-positive cocci (mainly from Staphylococcus and Micrococcus/Kocuria genera) and endospore-forming Gram-positive rods from Bacillus genus. Among the most common fungal representatives were those from Alternaria, Aspergillus, Cladosporium and Penicillium genera.
Źródło:
Rocznik Ochrona Środowiska; 2018, Tom 20, cz. 2; 1564-1582
1506-218X
Pojawia się w:
Rocznik Ochrona Środowiska
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Bacteriological Air Quality at Animal Veterinary Practice
Bakteriologiczna jakość powietrza w gabinecie weterynaryjnym
Autorzy:
Bulski, Karol
Frączek, Krzysztof
Cendrowska, Anna
Chmiel, Maria J.
Powiązania:
https://bibliotekanauki.pl/articles/1812012.pdf
Data publikacji:
2019
Wydawca:
Politechnika Koszalińska. Wydawnictwo Uczelniane
Tematy:
bioaerosol
bacteria
air
animal veterinary practice
bioaerozol
bakterie
powietrze
gabinet weterynaryjny
Opis:
Due to the nature of the work (animal treatment and care of animals) the environment of small animal veterinary practice can be contaminated by microorganisms. Therefore, veterinary practices or hospitals are facilities, where veterinarians, clients and animals can be exposed to biological agents. The objective of the study was to characterize the bacteriological quality of air in small animal veterinary practice in Krakow. Bioaerosol measurements were performed during the summer season of 2017. The samples of outdoor and indoor air at small animal veterinary practice were analyzed, using a 6-stage Andersen's air sampler. The highest concentration of bacterial aerosol was observed in the treatment room. There were statistically significant differences in the concentrations of bacterial aerosol between indoor and out-door air. Also, the analysis showed that there were significantly higher airborne microbial loads in different rooms at different measuring times of the day. Based on the analysis of bioaerosol particle size distribution it was found that the largest "load" of bacteria, isolated form the air, can reach (in the human respiratory system) to the region of the nasal and oral cavity, throat and trachea, as well as bronchioles. In the indoor air, the predominant groups of microorganisms were rods of the Bacillus genus and Gram-positive cocci from the Micrococcus and Staphylococcus genus. The study confirmed that the small animal veterinary practice can be a workplace related to exposure to microbial agents.
Ze względu na specyfikę pracy (leczenie oraz opieka nad zwierzętami) środowisko gabinetu weterynaryjnego może być zanieczyszczone mikrobiologicznie. Gabinety czy szpitale weterynaryjne są placówkami, w których weterynarze, klienci i zwierzęta mogą być narażeni na działanie czynników biologicznych. Celem badań była charakterystyka bakteriologicznej jakości powietrza w gabinecie weterynaryjnym w Krakowie. Pomiary bioaerozolu wykonano w okresie lata w 2017 r. Próbki powietrza zewnętrznego oraz wewnętrznego w gabinecie weterynaryjnym pobierano przy pomocy 6-stopniowego impaktora Andersena. Najwyższe stężenie aerozolu bakteryjnego obserwowano w pokoju zabiegowym. Odnotowano istotne statystycznie różnice w stężeniach aerozolu bakteryjnego pomiędzy powietrzem wewnętrznym, a tłem zewnętrznym. Analiza wykazała również istotnie wyższe stężenia mikroorganizmów w zależności od punktu pomiarowego i pory dnia. Analizując rozkłady ziarnowe bioaerozolu stwierdzono, że najwyższy „ładunek” bakterii może dotrzeć (w układzie oddechowym człowieka) do rejonu jamy nosowej i jamy ustnej, gardła i tchawicy, a także oskrzelików. W powietrzu wewnętrznym dominującymi grupami mikroorganizmów były laseczki z rodzaju Bacillus i Gram-dodatnie ziarniaki z rodzaju Micrococcus i Staphylococcus. Badanie potwierdziło, że gabinet weterynaryjny może być miejscem pracy związanym z narażeniem na czynniki mikrobiologiczne.
Źródło:
Rocznik Ochrona Środowiska; 2019, Tom 21, cz. 2; 841-854
1506-218X
Pojawia się w:
Rocznik Ochrona Środowiska
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Czynniki mikrobiologiczne na terenie wybranych krajowych portów lotniczych
Microbiological Agents at Selected Domestic Airports
Autorzy:
Stobnicka, A.
Gołofit-Szymczak, M.
Górny, R.
Powiązania:
https://bibliotekanauki.pl/articles/1813774.pdf
Data publikacji:
2018
Wydawca:
Politechnika Koszalińska. Wydawnictwo Uczelniane
Tematy:
szkodliwe czynniki biologiczne
bioaerozol
terminal lotniczy
harmful biological agents
bioaerosol
airport terminal
Opis:
Jednym z zagrożeń, zarówno dla pasażerów, jak i dla pracowników terminali lotniczych są szkodliwe czynniki biologiczne pochodzące z instalacji wentylacyjnych i przewożonego bagażu oraz te emitowane przez pasażerów. Wspomniane mikroorganizmy bakteryjne i grzybowe mogą wywierać niekorzystny wpływ na organizm człowieka poprzez działanie toksyczne, drażniące i alergizujące. W piśmiennictwie przedmiotu brakuje danych dotyczących zanieczyszczenia powietrza i powierzchni na terenie lotnisk. Celem niniejszej pracy była ocena ilościowa i jakościowa próbek bioaerozoli i wymazów powierzchniowych pobranych na terenie wybranych krajowych portów lotniczych. Badania zostały przeprowadzone w czasie siedmiu miesięcy, w okresie od kwietnia do października na terenie 3 krajowych terminali lotniczych, z których każde obsługuje powyżej 2 mln pasażerów. Pobieranie próbek powietrza przeprowadzone zostało stacjonarnie, metodą wolumetryczną za pomocą impaktora MAS (model 100, Merck, Darmstadt, Niemcy). Próbki wymazów powierzchniowych pobierano sterylną wymazówką zwilżoną solą fizjologiczną z wykorzystaniem jednorazowego sterylnego szablonu o powierzchni 100 cm2 (MEUS S.R.L., Piove Di Sacco, Włochy). Stężenie mikroorganizmów w powietrzu wyrażano w jednostkach tworzących kolonie na 1 m3, [jtk/m3] natomiast stężenie mikroorganizmów na powierzchniach w jednostkach tworzących kolonie na 1 cm2 powierzchni [jtk/cm2]. Uzyskane dane pomiarowe opracowano statystycznie w oparciu o test Kruskala-Wallis’a oraz analizę korelacji Spearman’a z wykorzystaniem programu STATISTICA. Identyfikację mikroorganizmów przeprowadzono w oparciu o analizę makroskopową i mikroskopową cech morfologicznych kolonii, uzupełnioną w przypadku bakterii i drożdży o analizę ich cech biochemicznych z zastosowaniem testów diagnostycznych API. Najwyższe średnie stężenie bakterii w powietrzu odnotowano w hali głównej (800 jtk/m3), natomiast najwyższe średnie stężenie grzybów w hali przylotów (250 jtk/m3). Najbardziej zanieczyszczonymi powierzchniami, pod kątem obecności zarówno bakterii (169 jtk/cm2), jak i grzybów (16 jtk/cm2) były taśmy bagażowe w punkcie kontroli bezpieczeństwa. W próbkach powietrza i na powierzchniach dominującą grupą mikroorganizmów były bakterie, które stanowiły odpowiednio od 40% do 100% oraz od 88,6% do 100% całości mikrobioty. Temperatura powietrza oraz wilgotność względna powietrza nie determinowała w sposób znaczący wielkości obserwowanych stężeń bioaerozoli. Jak wskazują wyniki analizy jakościowej, w bioaerozolach i na powierzchniach na terenie terminali lotniczych mogą występować zarówno bakteryjne i grzybowe szczepy saprofityczne należące do grupy 1. zagrożenia, jak i gatunki zaliczane do grupy 2. zagrożenia (Staphylococcus aureus, Streptomyces spp.), które mogą być przyczyną różnych chorób i dolegliwości zdrowotnych.
One of the hazards, both for passengers and for the workers at the airport terminals, are harmful biological agents emitted from the ventilation system, transported baggage and emitted by the passengers. These bacteria and fungi can cause adversely health effects on the human body through toxic, irritating and allergenic action. The data regarding microbial characteristic of bioaerosols and surfaces at the airports are scarce. The aim of the study was a quantitative and qualitative evaluation of microbial contamination of bioaerosols and surface swabs collected at selected domestic airport terminals. The samples were collected during 7 months from April to October at 3 domestic airport terminals. Each of them serves over 2 mln passengers. Air sampling was carried out with stationary, volumetric method using the MAS impactor (model 100, Merck, Darmstadt, Germany). Samples of surface swabs were collected with a sterile swab soaked with 0,9% NaCl with a disposable sterile template of 100 cm2 area (MEUS S.R.L., Piove Di Sacco, Italy). The concentration of microorganisms in bioaerosols was expressed in colony forming units per 1 m3 [CFU/m3] and the concentration of microorganisms on surfaces in colony forming units per 1 cm2 surface [CFU/cm2]. Statistical analyses were carried out with Kruskal-Wallis and Spearman correlation test using STATISTICA. Identification of microorganisms was based on macroscopic and microscopic analysis of morphological features of colonies, supplemented, in the case of bacteria and yeasts, with biochemical analysis using API diagnostic kits. The highest concentration of bacteria was detected in the main hall (800 CFU/m3), while the highest concentration of fungi in the arrivals hall (250 CFU/m3). The most contaminated surfaces, both with bacteria (169 CFU/cm2) and fungi (16 CFU/cm2) were luggage straps at the security check area. The predominant group of microorganisms in bioaerosols as well as on surface were bacteria, which constitued 40% to 100% and 88.6% to 100% of the total microbiota, respectively. The air temperature and relative humidity of the air did not significantly determine the concentration of bioaerosols. The qualitative analysis showed the presence of bacterial and fungal saprophytic strains belonging to the 1. risk group, and species belonging to the 2. risk group (Staphylococcus aureus, Streptomyces spp.), which are responsible for numerous adverse health outcomes and diseases.
Źródło:
Rocznik Ochrona Środowiska; 2018, Tom 20, cz. 2; 1147-1167
1506-218X
Pojawia się w:
Rocznik Ochrona Środowiska
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Impact of a Small Wastewater Treatment Plant on the Sanitary State of Atmospheric Air
Wpływ małej oczyszczalni ścieków na stan sanitarny powietrza atmosferycznego
Autorzy:
Jadczyk, Piotr
Sówka, Izabela
Pawnuk, Marcin
Wroniszewska, Alicja
Powiązania:
https://bibliotekanauki.pl/articles/1811649.pdf
Data publikacji:
2020
Wydawca:
Politechnika Koszalińska. Wydawnictwo Uczelniane
Tematy:
bioaerosol
bacteria
fungi
air pollution
wastewater treatment
bioaerozol
bakterie
grzyby
zanieczyszczenie powietrza
oczyszczalnia ścieków
Opis:
Wastewater treatment plants are the source of odour and microorganism emissions to the atmospheric air. Bioaerosol emitted by treatment plants may contain pathogenic microorganisms, antibiotic resistant microorganisms and cause allergies. The aim of the study was to assess the impact of the newly created municipal wastewater treatment plant using the activated sludge method (approx. 20,000 PE, average daily flow of 2,300 m3) on the sanitary state of atmospheric air. Numerous field obstacles (e.g. trees) and natural sources of microorganism emissions to the atmospheric air (e.g. drainage channels) were located in the vicinity of the wastewater treatment plant. Bioaerosol samples (3 replicates) were taken in a wind trail at 10 test stands on the leeward side of the treatment plant and two control stands on the windward side of the treatment plant. Samples were taken by sedimentation on Petri dishes with microbiological mediums. Media was incubated at a temperature appropriate for the type of microorganisms (psychrophilic bacteria, mesophilic bacteria, actinomycetes, mold fungi), and then colonies growing on media were counted. The number of microorganisms per unit volume of air was determined according to the Omelian formula in the Gogoberidze modification. Four series of tests were carried out during the transition months (spring and autumn). The concentration of microorganisms on the leeward side of the treatment plant in the following ranges amouted: psychrophilic bacteria: 156 ± 85 - 6578 ± 1286 cfu/m3, mesophilic bacteria: 87±24 - 6309 ± 1349 cfu/m3, actinomycetes: 0±0 - 719±12 cfu/m3, mold fungi: 52±42 - 4645±425 cfu/m3. These values were similar to those found in the area and in the vicinity of wastewater treatment plants examined by other authors. The concentration of microorganisms in the vicinity of the tested wastewater treatment plant did not show a downward trend as a function of distance from the wastewater treatment plant. This could be due to the presence of other sources of bioaerosol emissions to atmospheric air in the vicinity of the treatment plant (e.g. drainage canals, uncovered soil in plowed fields) and field obstacles that could have affected the movement of air masses (e.g. in-field woodland, forest, embankment Railway). The obtained research results indicate that the emission of bioaerosol from a small wastewater treatment plant, may cause changes in the concentration of microorganisms in the atmospheric air at a level close to natural sources. However, the threats to human health caused by bioaerosol emitted from municipal wastewater may be higher. Therefore, it is justified to monitor the sanitary state of the air and the atmosphere at the wastewater treatment plant and in its vicinity, and conduct research to develop an optimal set of indicator microorganisms of this state.
Oczyszczalnie ścieków są źródłem emisji odorów i mikroorganizmów do powietrza atmosferycznego. Bioaerozol emitowany przez oczyszczalnie może zawierać mikroorganizmy chorobotwórcze, mikroorganizmy oporne na antybiotyki oraz powodować powstawanie alergii. Celem pracy była ocena wpływu nowo powstałej oczyszczalni ścieków komunalnych oczyszczającej je metodą osadu czynnego, (ok. 20000 RLM, średni przepływ dobowy 2300 m3) na stan sanitarny powietrza atmosferycznego. W sąsiedztwie oczyszczalni znajdowały się liczne przeszkody terenowe (np. zadrzewienia) oraz naturalne źródła emisji mikroorganizmów do powietrza atmosferycznego (np. kanały melioracyjne). Próbki bioaerozolu (po 3 powtórzenia) pobierano w smudze wiatru na 10 stanowiskach badawczych po stronie zawietrzenj oczyszczalni i dwóch stanowiskach kontrolnych po stronie nawietrznej oczyszczalni. Próbki pobierano metodą sedymentacyjną na płytki Petriego ze zagaryzowanymi podłożami mikrobiologicznymi. Podłoża inkubowano w temperaturze odpowiedniej dla danego rodzaju mikroorganizmów (bakterie psychrofilne, bakterie mezofilne, promieniowce, grzyby pleśniowe), a potem liczono kolonie rosnące na podłożach. Liczbę mikroorganizmów w jednostce objętości powietrza określano według wzoru Omeliańskiego w modyfikacji Gogoberidze. Wykonano 4 serie badań w miesiącach przejściowych (wiosna i jesień). Stężenia mikroorganizmów po stronie zawietrznej oczyszczalni mieściły się w przedziałach: bakterie psychrofilne: 156±85 - 6578±1286 jtk/m3, bakterie mezofilne: 87±24 - 6309±1349 jtk/m3, promieniowce: 0±0 - 719±12 jtk/m3, grzyby pleśniowe: 52±42 - 4645±425 jtk/m3. Były to wartości zbliżone do stwierdzonych na terenie oraz w sąsiedztwie oczyszczalni ścieków badanych przez innych autorów. Stężenia mikroorganizmów w sąsiedztwie badanej oczyszczalni nie wykazywało tendencji spadkowej w funkcji odległości od oczyszczalni ścieków. Mogło to być spowodowane obecnością w sąsiedztwie oczyszczalni innych źródeł emisji bioaerozolu do powietrza atmosferycznego (np. kanałów melioracyjnych, odkrytej gleby na zaoranych na polach) oraz przeszkód terenowych, które mogły mieć wpływ na przemieszczanie się mas powietrza (np. zadrzewienia śródpolne, las, nasyp kolejowy). Uzyskane wyniki badań wskazują, że emisja bioaerozolu z małej oczyszczalni ścieków, w niektórych przynajmniej przypadka, może powodować zmiany stężenia mikroorganizmów w powietrzu atmosferycznym na poziomie zbliżonym do źródeł naturalnych. Zagrożenia dla zdrowia ludzkiego spowodowane przez bioaerozol emitowany ze ścieków komunalnym mogą być jednak większe. Dlatego uzasadnione jest monitorowanie stanu sanitarnego powietrza atmosferycznego na terenie oczyszczalni ścieków i w ich sąsiedztwie oraz prowadzenie badań nad opracowaniem optymalnego zestawu mikroorganizmów wskaźnikowych tego stanu.
Źródło:
Rocznik Ochrona Środowiska; 2020, Tom 22, cz. 2; 927-939
1506-218X
Pojawia się w:
Rocznik Ochrona Środowiska
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Air Quality in a Brewery Bottling Plant
Jakość powietrza w rozlewni piwa w browarze
Autorzy:
Połednik, B.
Dudzińska, M.
Czerwiński, J.
Polednik, A.
Powiązania:
https://bibliotekanauki.pl/articles/1818042.pdf
Data publikacji:
2016
Wydawca:
Politechnika Koszalińska. Wydawnictwo Uczelniane
Tematy:
air quality
aerosols
bioaerosols
carbonyl compounds
bottling plant
jakość powietrza
aerozol
bioaerozol
związki karbonylowe
rozlewnia piwa
Opis:
Przedstawione wyniki badań dotyczą jakości powietrza w rozlewni piwa. W trakcie normalnej pracy rozlewni mierzone były stężenia masowe i koncentracje ilościowe cząstek aerozolowych, stężenia bakterii i grzybów oraz stężenia związków karbonylowych w powietrzu. Stężenia aerozoli określano w sposób ciągły metodami spektrometrii optycznej. Zanieczyszczenia biologiczne oznaczano metodą sedymentacyjną wykorzystując płytki Petriego z odpowiednimi pożywkami. Stężenia związków karbonylowych w powietrzu określano metodą pasywną używając dozymetrów Radiello. Przy oznaczaniu stężeń zanieczyszczeń biologicznych i związków karbonylowych wykonano odpowiednio dwie i trzy serie pomiarowe w dwóch miejscach rozlewni piwa. Pomimo zautomatyzowania procesu rozlewania piwa do butelek zaobserwowano okresowe znaczące wzrosty stężeń mierzonych zanieczyszczeń. Średnie stężenia masowe wszystkich mierzonych frakcji cząstek aerozolowych miały podobne wartości i wynosiły ok. 0,2 mg/3. Maksymalnie ok. 5-cio krotne wzrosty koncentracji masowych cząstek obserwowano w nieregularnych odstępach czasu. Największe koncentracje ilościowe zmierzono dla cząstek drobnych. Średnie koncentracje cząstek o wielkościach 0,3-0,5 µm i 0,5-1 µm miały odpowiednio wartości 847 i 93 cząstki/c3. W przypadku zanieczyszczeń biologicznych średnie stężenie bakterii w powietrzu w rozlewni piwa wynosiło 1441 JTK/3, a średnie stężenie grzybów 557 JTK/3. Wartości te są niższe niż proponowane dopuszczalne poziomy stężeń bakterii i grzybów w budynkach użyteczności publicznej. Średnie stężenia mierzonych związków karbonylowych również nie przekraczały wartości, które są dopuszczalnych w środowisku pracy. Oprócz formaldehydu, którego okresowe stężenia wzrastały do prawie 800 µg/3 stężenia innych związków były w zakresie akceptowalnym dla pomieszczeń przeznaczonych na pobyt ludzi. Nieco wyższe stężenia niektórych związków karbonylowych odnotowano w punkcie pomiarowym w pobliży myjni butelek. Przedstawione wyniki wskazują, że istnieje potencjalne zagrożenie dla zdrowia pracowników rozlewni piwa związane z okresowymi wzrostami stężeń mierzonych zanieczyszczeń.
Źródło:
Rocznik Ochrona Środowiska; 2016, Tom 18, cz. 2; 591-602
1506-218X
Pojawia się w:
Rocznik Ochrona Środowiska
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Czynniki mikrobiologiczne na pokładzie lekkich samolotów pasażerskich
Microbial Agents on Board of Light Passenger Aircrafts
Autorzy:
Stobnicka, A.
Górny, R.
Gołofit-Szymczak, M.
Cyprowski, M.
Ławniczek-Wałczyk, A.
Powiązania:
https://bibliotekanauki.pl/articles/1818069.pdf
Data publikacji:
2016
Wydawca:
Politechnika Koszalińska. Wydawnictwo Uczelniane
Tematy:
lekkie samoloty pasażerskie
zanieczyszczenie powietrza
bakterie
grzyby
bioaerozol
light passenger aircrafts
air contamination
bacteria
fungi
bioaerosol
Opis:
Light passenger aircrafts, also known as „air taxis”, are a fast and comfortable way of transport, which becomes more and more popular nowadays. However, there is a lack of publications regarding harmful biological agents in the cabin air of light passenger aircrafts. The aim of the study was a quantitative and qualitative evaluation of microbial contamination of cabin air in eight light passenger aircrafts with open cabin type and two helicopters. The bioaerosol sampling was carried out with a stationary, volumetric method using MAS-100 NT impactor. The concentration of microorganisms was expressed as CFU/m3.The highest concentration of bacteria was detected in the helicopter Robinson R44 Raven 2 I (175 CFU/3), while the highest concentration of fungi was detected in the plane model TB9 Socata Tampico (385 CFU/m3). Kruskal-Wallis test did not show any statistically significant difference in the concentration of microorganisms in the air between the tested aircrafts, and between them and the outside background.The predominant groups of microorganisms in bioaerosols were fungi and Gram-positive cocci, which constituted 31.1-83.0% and 5.6-62.2% of the total microbiota, respectively. Sixteen species of bacteria belonging to the 8 types and 14 species of fungi belonging to 13 genera were identified in the samples.The qualitative analysis showed the presence of bacterial and fungal saprophytic strains belonging to the 1. risk group, and species belonging to the 2. risk group (Bacillus subtilis, Streptomyces spp.). Taking into account the influence of temperature and relative humidity on the concentration of bacteria and fungi in the air, it was observed that the higher temperature determined the higher concentration of bacteria, but there was no such relationship concerning fungi. Relative humidity did not significantly determine the concentration of bioaerosols.Our results indicate that the concentrations of bacteria and fungi in the cabin air were very low. However, even such an environment cannot be considered as free from pathogens. As shown by the results, the bioaerosols in the cabin air of light passenger aircrafts may contain potentially pathogenic bacteria and fungi belonging to the 2. risk group. However, bioaerosols may contain potentially pathogenic bacteria and fungi belonging to the 2. risk group. Direct contact with the afore-mentioned microorganisms, especially in the case of people with weakened immunity systems, can cause adverse health effects, as well as allergic reactions.
Źródło:
Rocznik Ochrona Środowiska; 2016, Tom 18, cz. 2; 492-505
1506-218X
Pojawia się w:
Rocznik Ochrona Środowiska
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Transport of Microbial Components in Coarse and Fine Particle Fractions in Office Buildings
Transport cząstek pochodzenia mikrobiologicznego w drobnej i grubej frakcji aerozolu w budynkach biurowych
Autorzy:
Ławniczek-Wałczyk, Anna
Górny, Rafał L.
Powiązania:
https://bibliotekanauki.pl/articles/1812026.pdf
Data publikacji:
2019
Wydawca:
Politechnika Koszalińska. Wydawnictwo Uczelniane
Tematy:
office
endotoxins
β-D-glucans
PM1
PM2.5
PM2.5-10
bioaerosol
biuro
endotoksyny
β-D-glukany
bioaerozol
Opis:
In old and modern interiors, particular attention is focused on the air quality as one of major determinants of the well-being of occupants. Exposure to microbiological contaminants in such close indoor space may be associated with the occurrence of various adverse health outcomes in the exposed individuals. Because the size of inhaled particles determines their place of deposition in the human airways and the associated adverse health outcomes, a detailed characteristic of airborne microbial components carried on fine dust particles in office buildings is needed. The aim of this study was to determine the concentrations of endotoxins, (1-3)-β-D-glucans and culturable microorganisms in coarse, fine and aerosol fractions collected in two office buildings in Warsaw. The concentrations of particulate aerosol were measured using Sioutas impactors in PM1, PM2.5, and PM2.5-10. Kinetic-QCL LAL and Glucatell assays were used to detect endotoxin and (1-3)-β-D-glucan concentrations, respectively. The bioaerosol samples were taken using six-stage Andersen impactor as coarse (> 7-2.1µm) and fine (< 2.1µm) fractions, as well. The mean concentrations of particulate aerosol, endotoxins and (1-3)-β-D-glucans in all studied offices were: in PM1 – 6 μg/m3, 4 EU/m3 and 5 ng/m3; in PM2.5 – 11 μg/m3, 6 EU/m3 and 10 ng/m3; and PM10-2.5 – 3.5 μg/m3, 2 EU/m3 and 2.5 ng/m3, respectively. The concentrations of endotoxins and (1-3)-β-glucans in PM2.5 were significantly higher than in PM10-2.5 (p < 0.01 and p < 0.001, respectively) and accounted for 71% and 84% of their total load in PM10. The airborne bacteria occurred mostly in fine fraction (average 3.9 · 102 CFU/m3, p < 0.01), while fungi in coarse fraction of aerosol (5.6 · 101 CFU/m3). The concentrations of endotoxins showed a positive correlation with PM1 (r = 0.61, p < 0.05) and PM2.5 levels (r = 0.76, p < 0.05) as well as with Gram-negative rods in fine fraction (r = 0.75, p < 0.05). The concentrations of (1-3)-β-D-glucans showed positive correlation with PM2.5 (r = 0.54, p < 0.05) and fungi in fine fraction (r = 0.59, p < 0.05). This study demonstrated that endotoxins and (1-3)-β-D-glucans are associated mostly with fine fraction of aerosol particles. Such particles can penetrate the lower parts of the human respiratory system posing a health risk for exposed people. The main source of endotoxins in the offices were Gram-negative rods. The sources of (1-3)-β-D-glucans were probably both fungal conidia and their fragments of aerodynamic diameters <2.1 μm. The noted concentrations of endotoxins and microorganism were within the range normally observed in this type of facilities. Nevertheless, constant monitoring of the hygienic condition is suggested, including regular cleaning and replacement of air filters in the air-conditioning system.
Zarówno w starych, jak i nowoczesnych wnętrzach budynków biurowych szczególną uwagę zwraca się na jakość powietrza, która jest wyznacznikiem dobrostanu mieszkańców. Narażenie na zanieczyszczenia mikrobiologiczne w takich zamkniętych pomieszczeniach może być związane z pojawianiem się różnych niekorzystnych efektów zdrowotnych u narażonych osób. Ponieważ wielkość wdychanych cząstek determinujeich miejsce osadzania w drogach oddechowych człowieka i związane z tym problemy zdrowotne, potrzebna jest szczegółowa charakterystyka frakcji cząstek pyłowych transportujących cząstki pochodzenia mikrobiologicznego w budynkach biurowych. Celem niniejszego badania było poznanie zakresów stężeń endotoksyn, (1-3)-β-D-glukanów i mikroorganizmów w drobnej i grubej frakcji aerozolu ziarnistego w dwóch budynkach biurowych w Warszawie. Stężenia aerozolu ziarnistego zmierzono przy użyciu impaktorów Sioutas we frakcjach PM1, PM2.5 i PM2.5-10. Testy Kinetic-QCL LAL i Glucatell zastosowano odpowiednio do detekcji endotoksyn i β-D-glukanów. Próbki biaerozolu pobrano przy użyciu sześcio-stopniowego impaktora Andersena we frakcji gruboziarnistej (> 7-2,1 μm) i drobnej (< 2,1 μm). Średnie stężenia aerozolu ziarnistego, endotoksyn i β-D-glukanów w wszystkich badanych biurach wynosiły odpowiednio: w PM1 – 6 μg/m3, 4 JE/m3 i 5 ng/m3; w PM2.5 – 11 μg/m3, 6 JE/m3 i 10 ng/m3 i w PM10-2.5 – 3.5 μg/m33, 2 JE/m3 i 2.5 ng/m3. Stężenia endotoksyn i β-D-glukanów w PM2.5 były znacznie wyższe niż w PM10-2.5 (odpowiednio p < 0.01 i p < 0.001) i stanowiły 71% i 84% frakcji PM10. W badanych pomieszczeniach, bakterie występowały głównie w drobnej frakcji aerozolu (3.9·102 JTK/m3, p < 0.01), podczas gdy grzyby izolowano najczęściej z frakcji gruboziarnistej aerozolu (5.6·101 JTK/m3). Stwierdzono pozytywną korelację pomiędzy stężeniami endotoksyn a stężeniami pyłu PM1 (r = 0.61, p < 0.05) i PM2.5 (r = 0.76, p < 0.05), jak również Gram-ujemnymi pałeczkami (r = 0.75, p < 0.05). Stężenia β-D-glucans wykazały korelację z PM2.5 (r = 0.54, p < 0.05) oraz grzybami w drobnej frakcji (r = 0.59, p < 0.05). Niniejsze badania wykazały, że głównym nośnikiem endotoksyn i (1-3)-β-Dglukanów w pomieszczeniach biurowych były drobne frakcje aerozolu ziarnistego. Cząstki te mogą przenikać do dolnych dróg oddechowych powodując niekorzystne skutki zdrowotne u narażonych osób. Stwierdzono, że głównym źródłem endotoksyn były Gram-ujemne pałeczniki. Źródłami (1-3)-β-D-glukanów były głównie fragmenty strzępek grzybni (lub spor) o aerodynamicznych średnicach <2,1 μm. Odnotowane stężenia endotoksyn i mikroorganizmów w biurach mieściły się w zakresie normalnie obserwowanym w tego typu obiektach. Niemniej jednak sugerowane jest stałe monitorowanie stanu higienicznego tych pomieszczeń, w tym regularne czyszczenie i wymienianie filtrów powietrza w instalacji klimatyzacyjnej.
Źródło:
Rocznik Ochrona Środowiska; 2019, Tom 21, cz. 2; 1099-1115
1506-218X
Pojawia się w:
Rocznik Ochrona Środowiska
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-8 z 8

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies