Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "Zanieczyszczenia wody" wg kryterium: Temat


Wyświetlanie 1-6 z 6
Tytuł:
An approach for assessment of waterborne bioavailable organic contaminants using Semipermeable Membrane Devices (SPMDS)
Próba wyznaczenia stężeń organicznych, bio-przyswajalnych zanieczyszczeń w wodzie przy zastosowaniu syntetycznych błon półprzepuszczalnych (SPMD)
Autorzy:
Pazdro, K.
Powiązania:
https://bibliotekanauki.pl/articles/1826258.pdf
Data publikacji:
2002
Wydawca:
Politechnika Koszalińska. Wydawnictwo Uczelniane
Tematy:
syntetyczne błony półprzepuszczalne
SPMD
stężenia organiczne
zanieczyszczenia wody
Opis:
A large amount of anthropogenic, organic pollutants has entered the global aquatic environment during the past decades. Many of them, like polycyclic aromatic hydrocarbons, pesticides, polichlorinated biphenyls and dioxins are considered to be hazardous to the environment. Their mobility through air and water, accumulation and/or transformation processes in the environment and finally their biomagnification, constitute a real risk to human health, wildlife and the environment [1,31]. Most of organic micropollutants are hydrophobic and biochemically resistant that cause the compounds bioconcentrate in the fatty tissues of organisms. Knowledge of the potential bioavailability of a pollutant, present in the environment is essential for ecosystem risk assessment and further effects studies [11,34]. This has induced many countries to promote monitoring programs and stepwise evaluation processes. Limitations in nearly all currently employed techniques and analytical methodology impede comprehensive exposure assessments. These limitations include the use of single point in time sampling methods, analytical methods having insufficient sensitivity to determine trace levels of contaminants in water. Bivalve mollusks have been recommended by many as the most suitable monitoring organisms for bioaccumulation of trace contaminants in fresh, marine and estuarine waters [11]. Programs such as the National Oceanic and Atmospheric Administration's National Status and Trends program [19,33] exemplify the utility of this approach to pollutant monitoring. However, monitoring with mussels often encounters some problems, like natural anatomical and behavioral variability of indigenous populations and mortality of organisms in many harsh environments [13]. To avoid these problems, interest in the use of in situ passive sampling approach for assessing environmental pollutant exposure has increased world-wide. By far the most commonly used passive sampler is semipermeable membrane device (SPMD), first described by Huckins et al., [14]. The objectives of this study are to present the theoretical background of organic contaminants sampling by SPMDs. A field study, undertaken in Atlantic coastal waters of France exemplifies a practical application of SPMDs. The field experiment aimed to compare the occurrence and individual PAHs distribution in SPMDs and in the co-deployed mussels, Mytilus galloprovincialis as well as to estimate the ambient water PAH concentrations from the SPMD results.
Jednym z głównych problemów dotyczących losu organicznych zanieczyszczeń wprowadzanych do środowiska przez człowieka, jest określenie ich potencjalnej przyswajalności przez organizmy żywe. Rzetelne oszacowanie poziomów stężeń w otaczającym środowisku jak również ich specjacji jest konieczne do wyjaśnienia mechanizmów wpływu zanieczyszczeń organicznych na funkcjonowanie ekosystemu jak również do określenia zależności pomiędzy zanieczyszczeniami rozpuszczonymi w kolumnie wody a realną ekspozycją organizmów. W ostatnich latach obserwuje się znaczny wzrost zainteresowania zastosowaniem pasywnych technik pomiarów "in situ". Jedną z najbardziej obiecujących technik w przypadku zanieczyszczeń organicznych jest zastosowanie SPMD - syntetycznych błon półprzepuszczalnych wypełnionych neutralnym lipidem, opracowanych przez Huckinsa i wsp. W ramach publikacji opisano teoretyczne założenia działania SPMD i oraz zagadnienia dotyczące kinetyki pobierania zanieczyszczeń przez SPMD. Eksperyment przeprowadzony w morskich wodach przybrzeżnych ilustruje praktyczne zastosowanie syntetycznych błon półprzepuszczalnych w badaniach środowiskowych. SPMDs oraz małże z gatunku Mytilus galloprovincialis zostały umieszczone równolegle w toni wodnej w celu określenia bioprzyswajalnej frakcji wielopierścieniowych węglowodorów aromatycznych (WWA) rozpuszczonych w wodzie. Jednocześnie pobrano duże objętości wody w celu zmierzenia stężeń WWA w wodzie. Wyniki przeprowadzonego eksperymentu wykazały że zarówno SPMDs jak i małże efektywnie zatężały związki z grupy WWA o szerokim zakresie polarności i mas cząsteczkowych. Całkowite stężenie WWA w małżach i w SPMD kształtowało się na podobnym poziomie. Pomimo różnic w przypadku pojedynczych związków wykazano, że stężenie WWA w małżach można określić na podstawie stężenia w SPMD stosując równania regresji liniowej. Na bazie stężeń WWA w SPMD oszacowano stężenia w otaczającej wodzie i porównano ze stężeniami zmierzonymi. Szacowanie na podstawie stężeń w SPMD pozwoliło na określenie stężeń WWA, niewykrywalnych klasyczną metodą ekstrakcji na żywicy typu XAD. Przeprowadzony eksperyment potwierdził możliwość stosowania syntetycznych błon półprzepuszczalnych jako wiarygodnego narzędzia monitorowania poziomów zanieczyszczeń organicznych oraz badania ich bioprzyswajalności w środowisku morskim.
Źródło:
Rocznik Ochrona Środowiska; 2002, Tom 4; 189-205
1506-218X
Pojawia się w:
Rocznik Ochrona Środowiska
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Removal/reduction of organic pollutants from aqueous environment
Usunięcie/redukcja zanieczyszczeń organicznych ze środowiska wodnego
Autorzy:
Sarkar, M.
Das, M.
Manna, S.
Acharya, P.
Powiązania:
https://bibliotekanauki.pl/articles/1826240.pdf
Data publikacji:
2003
Wydawca:
Politechnika Koszalińska. Wydawnictwo Uczelniane
Tematy:
zanieczyszczenia organiczne wody
adsorpcja siarczanu
jakość wody
Opis:
The problem of considerable contamination of the aqueous environment with organic pollutants still requires the development of quick and simple methods for the removal, separation and determination of these compounds. The main classes of organic compounds that most of the industries use and discharge into the effluents are phenol, surfactant and dye. All these compounds are troublesome contaminants which pose not only to toxicity and health hazards but also hamper the environmental treatment processes. In chemical industry phenol is considered as an important starting materials for numerous intermediates and finished products. It is used for the production of a wide range of consumer goods and process materials ranging from adhesives, resins, emulsifiers and detergents, plasticizers, herbicides, dyes and flavors. The worldwide production of phenol is estimated to be 5 million tons per year. Phenol and its analogues are known to be toxic to microbes. The sign of acute illness induced by phenols in experimental animals as well as in humans is known. Continuous ingestion of phenol for a prolonged period of time causes mouth sore, diarrhoea, excretion of dark urine and impaired vision at concentration levels 10÷240 ppm. Lethal blood concentration for phenol is around 1.3 g/L. phenols are toxic to several biochemical functions and to fish life. It acts as a substrate inhibitor in the bio-transformation. World Health Organization (WHO) prescribed a concentration 1 ppb as the guideline concentration in drinking water [1]. Disposal of dyeing industry waste water pose one of the major problem, because such effluents contain a number of contaminants including acid or base, dissolve solids, surfactants and color. Out of these, color is the first contaminant to be recognized because it is visible to human eye. The dye causes the harmful action to various aquatic lives. As it is resistant to light it protects the sunlight from penetrating through it and reduces the aesthetic quality of water. Possible methods of color removal include chemical oxidation, froth flotation, coagulation, adsorption, etc. The anionic surfactants generally are removed by the chemical precipitation, foam separation, ultrafiltration and adsorption. Possible means of removal of phenols from waste water include ion exchange, reverse osmosis, chemical oxidation, precipitation, distillation, gas stripping, solvent extraction, adsorption or bio remediation. Removal of SDS, 4-nitrophenol and malachite green by activated carbon is an efficient and acceptable process. But the cost of operation is very high. Therefore, the present study is undertaken using fly ash as the adsorbent. Compared to activated carbon the efficiency of removal is less in case of 4-nitrophenol and SDS. But fly ash, being a waste material, is very cheap; only the carrying cost from the site of thermal plant to the laboratory is needed. Thus the use of fly ash in removing organic pollutants appears to be a cost viable. The simplicity of the technique makes the process quite acceptable.
Obecność organicznych zanieczyszczeń w strumieniu ścieków znacznie degraduje jakość wody. Zarówno własność estetyczne jaki i organizmy wodne stają wobec niebezpieczeństwa związanego z taką degradacją. Usunięcie zanieczyszczeń organicznych szczególnie za pomącą prostych i tanich metod jest wyzwaniem dla naukowców zajmujących się środowiskiem. Obecnie komunikaty naukowe mówią o możliwości zastosowania popiołów lotnych, odpadów stałych powstających w elektrociepłowniach, w usuwaniu albo redukcji ładunków niektórych organicznych zanieczyszczeń. W referacie przedstawiono wyniki badań nad adsorpcją siarczanu dodecylu sodu SDS (anionowy środek powierzchniowo czynny), zieleni malachitowej MG oraz 4-nitrofenolu na popiołach lotnych. Usunięcie SDS, 4-nitrofenolu i zieleni malachitowej na węglu aktywnym jest skutecznym i zadowalającym procesem. Ale koszt tej operacji jest bardzo wysoki. Dlatego, przedsięwzięto obecne badania używając popiołów lotnych jako substancji adsorbująca. W porównaniu do węgla aktywnego efektywność usunięcia na popiołach lotnych jest mniejsza w przypadku 4-nitrofenolu i SDS. Ale popioły lotne, będąc odpadem, są bardzo tanie. W ten sposób użycie popiołów lotnych w usuwaniu organicznych zanieczyszczeń okazuje się być wykonalne pod względem kosztów. Proces jest wykonalny kinetycznie i termodynamicznie, prosty w wykonaniu i tani.
Źródło:
Rocznik Ochrona Środowiska; 2003, Tom 5; 79-86
1506-218X
Pojawia się w:
Rocznik Ochrona Środowiska
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Wahania składu fizyczno-chemicznego wód rzeki Narwi z uwzględnieniem zawartości pestycydów fenoksyoctowych
Changes of physical and chemical composition of river Narew water taking into consideration concentration of phenoxyacetic pesticides
Autorzy:
Ignatowicz-Owsieniuk, K.
Powiązania:
https://bibliotekanauki.pl/articles/1826265.pdf
Data publikacji:
2002
Wydawca:
Politechnika Koszalińska. Wydawnictwo Uczelniane
Tematy:
pestycydy
skład fizyko-chemiczny wody
zanieczyszczenia wody
środki ochrony roślin w wodzie
Opis:
W zdegradowanym środowisku wodnym obecne są liczne zanieczyszczenia obce, do których należy zaliczyć substancje będące wynikiem intensywnej działalności gospodarczej ludzi. Ostatnie dziesięciolecia przyniosły znaczący wzrost chemizacji rolnictwa, przemysłu i innych dziedzin życia człowieka. Dążenie do zaspokojenia potrzeb żywnościowych ludności niesie za sobą konieczność coraz częstszego stosowania środków chemicznych służących polepszeniu jakości i ilości płodów rolnych. Do takich substancji niezaprzeczalnie należą środki ochrony roślin oraz substancje pożywkowe w postaci nawozów sztucznych. W ciągu ostatnich lat nastąpił wzrost zużycia herbicydów, wśród których w największych ilościach stosowane są herbicydy pochodne kwasu fenoksyoctowego (2,4-D, MCPA, MCPP). Nieuniknione w związku z tym jest przenikanie tych substancji z gleby do wód naturalnych, a w pierwszej kolejności do wód powierzchniowych. Pestycydy łatwo rozpuszczalne w wodzie bardzo szybko wymywane są z gleb terenów rolniczych i wprowadzane do wód. Herbicydy fenoksyoctowe należą właśnie do takich substancji. Ich rozpuszczalność w wodzie w temperaturze około 20oC wynosi odpowiednio: 2,4-D=600 mg/l, MCPA=1605 mg/l, MCPP=620 mg/l. Przepisy Unii Europejskiej precyzyjnie określają jakość wód powierzchniowych przeznaczonych do poboru wody pitnej, charakteryzują metody pomiaru i częstotliwość pobierania próbek tych wód, a także podobnie jak już obowiązujące przepisy polskie, określają dopuszczalne stężenia substancji pestycydowych w wodzie pitnej. Żadne dostępne źródło nie podaje informacji dotyczących występowania środków ochrony roślin w wodach rzeki Narwi. Według danych Regionalnego Zarządu Gospodarki Wodnej w Warszawie [14] jako substancje toksyczne rozpatrywano jedynie zanieczyszczenia uwzględnione w Dyrektywie 86/280/EEC [5] (w sprawie wartości dopuszczalnych dla ścieków i wskaźników jakości wód w odniesieniu do zrzutów niektórych niebezpiecznych substancji). Wyniki jednorazowej oceny wykazały, że zanieczyszczenia chloroorganiczne oraz metale ciężkie nie stanowiły zagrożenia, ponieważ nie przekraczały norm dopuszczalnych dla wód I klasy czystości. Jednocześnie należy podkreślić, że przy jednokrotnym badaniu pestycydów w roku, wynik oceny może być przypadkowy. Ponadto należy podkreślić, że oznaczano pestycydy nie stosowane od wielu lat, zamiast związków używanych obecnie do zabiegów agrotechnicznych. W związku z tym niniejsza praca stanowi cenne źródło informacji o występowaniu herbicydów fenoksyoctowych w wodach powierzchniowych naszego regionu. Okazało się, iż stężenia tych substancji w Narwi są wielokrotnie wyższe niż w monitorowanych w latach 80. i 90. wodach Raduni i Redy [19]. Analizując stężenia oraz okres występowania herbicydów, a także związków biogennych stwierdzono, że istnieje zależność miedzy ilością tych substancji i czasem wykrycia a zamożnością okolicznych rolników. W bogatszych, lepiej sytuowanych wsiach nawozy oraz herbicydy stosowane były dwukrotnie w roku, zaś w biednych wsiach tylko raz w roku, ewentualnie wcale. Należy także wspomnieć o dużym wpływie na stan czystości rzeki Narwi wody spuszczanej ze zbiornika Siemianówka [17,18]. Niosły one ze sobą zanieczyszczenia organiczne powodujące barwę i mętność, a także roślinność przyczyniającą się do ubytku tlenu rozpuszczonego oraz wiele innych zanieczyszczeń.
The presence of pesticides in natural waters of such countries as: USA, Canada, Russia, Germany, France, Switzerland and also in the Baltic Sea and the North Sea has been proved many times. The following compounds are detected most often and in largest quantities: Lindan, DDT (which has not been used for many years now), Simazine, Atrazine, Chlorfenvinphos and Fenitrothion. The presence of pesticides in surface waters in the Żuławy Wiślane region has been described many times by Żelechowska and Makowski. Additionally, the author's own research confirmed the presence of phenoxyacetic acid herbicides in surface waters in the northern-eastern region of Poland - in the Supraśl, Białka, Narew, Ploska and Biebrza rivers. This paper presents the results of the research on determination of phenoxyacetic herbicides and other pollutants concentrations in the Narew river. Narew is a right tributary of Vistula and it is 484 km long (along borders of Poland 448.1 km). Narew and its inflows embrace area of 75175.2 km2 (in Poland 53787 km2). The upper part of Narew and its inflows are on comparatively weakly industrialized areas (with typical agricultural character) and large forest areas. Near the Belarus border the barrage and reservoir called Siemianówka is situated. From sources to outlets the river flows across a comparatively flat ground. It is controlled when it flows onto Łomża ground. It goes across a flat valley (there were many meanders earlier). From the outlet of Biebrza Narew has a natural course. It flows here in a wide valley, which is the south bank of Biebrza valley. At Pniewo and Krzewo the valley of Biebrza narrows and farther the river flows into a narrow valley. Near Nowogród it flows into a wide valley (which is a natural edge of Kurpie Plain) with sandy basis. The samples were collected over a period of one year, from April 2000 to March 2001. Unfortunately any accessible sources do not give any data about usage of chemicals for protecting plants in the Narew catchment's area. This is not acceptable that such monitoring investigations have not been done. This work is a source of information about occurrence of phenoxyacetic acid- vinegar herbicides in surface water in our region. It has turned out that concentrations of these substances in Narew are many times higher than in monitored water of Radunia and Reda in Żuławy Wiślane. Analyzing concentrations and a period of occurrence of herbicides as well as concentrations biogene substances one may notice that there is a dependence between the quantity of these substances, the detection time and the wealthy of farmers. In richer, better-situated villages the fertilizers and herbicides were applied twice a year, while in poor villages only once a year or not at all. This has a large influence on a state of cleanness of water which is much worse from reservoir Siemianówka to Narew. Water carries organic pollution that causes colour and turbidity. It carries also plants that cause decrease of oxygen. The most important fact noted during the research is that in surface water taken for drinking significant amounts of crop protection products were determined, which, in the light of the new act concerning quality of drinking water, irrefutably must be removed in the treatment processes. Monitoring research carried out by the Environment Protection Institute in Białystok as well as the Regional Water Management Board in Warsaw in the Narew river's catchment allow only in limited range introducing EU directives, because localization of sections, range of determined pollutants as well as frequency of examinations are not always according to the EU directives.
Źródło:
Rocznik Ochrona Środowiska; 2002, Tom 4; 271-289
1506-218X
Pojawia się w:
Rocznik Ochrona Środowiska
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Zmiany wskaźników fizykochemicznych wody kanału Dąbrówka spowodowane działalnością kopalni rud cynku i ołowiu
Autorzy:
Policht-Latawiec, A.
Kanownik, W.
Lekstan, M.
Powiązania:
https://bibliotekanauki.pl/articles/1818628.pdf
Data publikacji:
2015
Wydawca:
Politechnika Koszalińska. Wydawnictwo Uczelniane
Tematy:
jakość wody
metale ciężkie
zanieczyszczenia
water quality
heavy metals
pollutions
Opis:
The paper presents changes of physicochemical indices of water in the Dąbrówka channel which is the receiving water of waters originating in the first place from drainage of zinc and zinc ores mines from ZGH Bolesław Company in Bukowno. Mining wastewaters are treated as a specific kind of sewage which do not form during a technological process but are the natural outcome of conducted mining activity. Beside mining wastewaters pumped out from the Pomorzany mine, the Dąbrówka channel drains also post-floatation waters from tailings ponds and runoffs from industrial wastes heaps. Hydrochemical tests were conducted in 2012. Water for analyses was collected once a month (total of 12 dates) in 3 control points: point 1 – at km 4+800 of the Dąbrówka channel – discharge of mining waters from the mine through the Dąbrowka shaft, point 2 – at 1+600 of the watercourse (below the national road 94), point 3 – at 3–50 m before the confluence of the Dąbrówka channel and the Biała River. The area of the Dąbrówka catchment is 16.64 km2. Settlement and industrial areas are situated in the upper part of the catchment, the area below is used as forest grounds. Bolesław town is situated in the central part (between points 1 and 2). The lower part of catchment is managed for agriculture with a minor share of settlement areas. Hydrochemical tests conducted on site comprised measurement of water pH, electrolytic conductivity (EC), dissolved oxygen concentration and degree of water saturation with oxygen. Laboratory assessments comprised total suspended solids by drying and weighing method, total dissolved solids by evaporation, concentrations of Ca2+, Mg2+, Na+, K+, Mn2+, Fe2+, Fe3+ (total iron) and heavy metals Zn and Pb by means of atomic absorption spectrometry (ASA) on UNICAM SOLAR 969 spectrometer. Concentration of ammonium nitrogen (N-NH4+), nitrite (N-NO2-) and nitrate (N-NO3-) nitrogen as well as phosphates (PO43-) and chlorides (Cl-) were determined using flow colorimetric analysis on FIAstar 5000 apparatus, whereas sulphate (SO4-2)concentration was assessed by precipitation method. Quality of the Dąbrówka channel water was estimated in compliance with the Regulation of the Minister of the Environment of 30 October 2014. Statistical inference about the significance of differences between the indices values among the control points was conducted using Kruskal-Wallis non-parametric test and then by non-parametric Mann-Whitney U-test on the significance level α = 0.05. On the basis of the investigations it was determined that water along the whole length of the Dąbrówka channel does meet the requirements of class II. Because of high concentration of lead, the water was classified to the state below good. The mining wastewater discharged from the zinc and lead ore mines was characterized by statistically lower concentrations of salinity indices, ammonium, and Fe and Mn, but higher content of heavy metals (Zn) and nitrate nitrogen than waters in the lower course of the channel.
Źródło:
Rocznik Ochrona Środowiska; 2015, Tom 17, cz. 2; 1350-1364
1506-218X
Pojawia się w:
Rocznik Ochrona Środowiska
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Influence of Catchment Use on the Degree of River Water Pollution by Forms of Phosphorus
Wpływ użytkowania zlewni na stopień zanieczyszczenia wód rzecznych formami fosforu
Autorzy:
Wojtkowska, M.
Bojanowski, D.
Powiązania:
https://bibliotekanauki.pl/articles/1813708.pdf
Data publikacji:
2018
Wydawca:
Politechnika Koszalińska. Wydawnictwo Uczelniane
Tematy:
river waters
forms of phosphorus
eutrycosis
sources of pollution
wody rzeczne
formy fosforu
eutryzacja
źródła zanieczyszczenia
Opis:
The subject of dissertation was analysis of wastewater and sewage management on water quality in particular rivers by assessment of eutrophication level of those rivers. Scope of work concerned analysis of phosphorus forms: total phosphorus, orthophosphates, polyphosphates and organic phosphorus. To complete the subject of dissertation, four watercourses were selected. All of them are placed in the Masovian Voivodeship: Długa, Pisia Gągolina, Utrata rivers and Srebrna stream. All of them have several common features. Those are lowland rivers, located near to Warsaw agglomeration. Długa and Srebrna have sources near to Mińsk Mazowiecki (city placed to the east from Warsaw). Pisia Gągolina and Utrata flow through districts on west from Warsaw and flows into Bzura near Sochaczew city. Sources of contamination in all river are mainly: disposal of wastewater from water treatment plants, leaks from septic tanks (damaged or intentionally leaked), surface runoff from agricultural areas and roads, landfill leachate. The ecological state of all watercourses, according to WIOŚ (Regional Inspectorate for Environmental Protection) monitoring is bad. Research showed that, the lowest concentration of total phosphorus was in the waters of Utrata (average 0.38 mg P/l), while the highest in Długa – average 2.8 mg P/l. Average concentration of orthophosphates was between 0.23 mg P/l (Długa) and 0.45 mg P/l (Pisia Gągolina). Basing on conducted analysis, it can be stated that phosphate contamination in all four watercourses is high, which leads to conclusion that eutrophication level is high. Reasons of that state can be caused by sewage disposals and agriculture. In three perennial streams (Długa, Pisia Gągolina and Srebrna), the highest share in total phosphorus concerned orthophosphates. It means, that phosphorus compounds in rivers are in some part subject to self-cleaning processes. In the case of Długa river, organic phosphorus is a main part of total phosphorus (71%). Source of organic phosphorus may be substances from decomposition of organic matter, mainly proteins. Condensed phosphates occurs as the result of wastewater inflow with surfactants containing phosphorus. Orthophosphates may occur as the result of leaching from soils or as the result of transformations of other phosphorus forms in water (mineralization, hydrolysis). Range of phosphates concentration occurs even on short segments of rivers. It is caused by strong influence of agriculture, breeding ponds and wastewater from treatment plants. Municipal treatment objects have strong influence on water quality and the contamination caused by them can be carried over long distances from place of sewage discharge. General state of water quality of all analyzed rivers, is bad.
Celem pracy było dokonanie analiza wpływu obiektów gospodarki wodno-ściekowej na jakość wody w wybranych rzekach poprzez ocenę stopnia eutrofizacji tych rzek. Zakres pracy obejmował analizę form fosforu: fosforu ogólnego, ortofosforanów, polifosforanów oraz fosforu organicznego w wodach rzecznych. W celu realizacji zaplanowanych zadań, do badań wytypowano cztery cieki wodne, znajdujące się na terenie województwa mazowieckiego – rzeki: Długa, Pisia Gągolina i Utrata oraz struga Srebrna. Wszystkie cztery rzeki wykazują pewne cechy wspólne. Są to rzeki nizinne, przepływające w pobliżu aglomeracji warszawskiej. Długa i Srebrna mają swe źródło w pobliżu Mińska Mazowieckiego (miasto na wschód od Warszawy). Rzeki Pisia Gągolina i Utrata przepływają przez powiaty na wschód od Warszawy i obie uchodzą do Bzury w okolicach Sochaczewa. Źródła występujących zanieczyszczeń to przede wszystkim zrzuty ścieków z oczyszczalni, przecieki z nieszczelnych (uszkodzonych, bądź świadomie rozszczelnionych) zbiorników bezodpływowych, spływ powierzchniowy z terenów rolniczych oraz z dróg, odcieki ze składowisk odpadów. Stan ekologiczny wód, według monitoringu prowadzonego przez WIOŚ, dla wszystkich omawianych cieków jest zły. Przeprowadzone badania wykazały, że najmniejsze stężenia fosforu ogólnego odnotowano w wodach Utraty – średnio 0,38 mg P/l, natomiast największe w Długiej: średnio 2,8 mg P/l. Średnia zawartość ortofosforanów wynosiła od 0,23 mg P/l (rzeka Długa) do 0,45 mg P/l (rzeka Pisia-Gągolina). Na podstawie przeprowadzonej analizy można stwierdzić wysokie zanieczyszczenie fosforanami wody wszystkich czterech rzek. W trzech badanych ciekach, największy udział w odniesieniu do fosforu ogólnego stwierdzono dla ortofosforanów. W przypadku rzeki Długiej, przeważa zawartość fosforu organicznego (71%). Źródłem fosforu organicznego mogą być substancje pochodzące z rozkładu materii organicznej, głównie białek. Fosforany skondensowane występują na skutek dopływu do rzek ścieków komunalnych zawierających substancje powierzchniowo czynne, których składnikiem jest fosfor. Ortofosforany mogą pojawiać się na skutek wymywania fosforu z gleby lub na skutek zachodzących w wodach przemian związków fosforu, jak mineralizacja czy hydroliza. Stężenie fosforanów na niewielkich odcinkach rzek występuje w szerokim zakresie wartości. Ma to związek z dużym wpływem terenów rolniczych, stawów hodowlanych oraz odprowadzanych ścieków z oczyszczalni ścieków komunalnych. Obiekty gospodarki komunalnej mają znaczny wpływ na jakość wód, a zanieczyszczenia z nich pochodzące mogą być przenoszone na duże odległości od miejsca zrzutu ścieków. Ogólny stan jakości wód we wszystkich badanych rzek jest zły.
Źródło:
Rocznik Ochrona Środowiska; 2018, Tom 20, cz. 1; 887-904
1506-218X
Pojawia się w:
Rocznik Ochrona Środowiska
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Ocena efektu ekologicznego wynikającego z zastosowania kolektorów słonecznych
Assessment of the Environmental Effects Resulting from the Use of Solar Collectors
Autorzy:
Żukowski, M.
Powiązania:
https://bibliotekanauki.pl/articles/1818047.pdf
Data publikacji:
2016
Wydawca:
Politechnika Koszalińska. Wydawnictwo Uczelniane
Tematy:
kolektory słoneczne
podgrzewanie wody użytkowej
odnawialne źródła energii
zanieczyszczenia powietrza
pakiet klimatyczno-energetyczny
systemy solarne
solar collectors
solar domestic
hot water system
renewable energy sources
air pollutants
climate and energy package
Opis:
Climate and energy package is a set of rules designed by member states of European Union to combat climate change. According to these directives the greenhouse gas emissions should be reduced by 20% and the share of energy produced from renewable sources should simultaneously be increased by the same percentage. The use of solar collectors can both improve energy security and reduce the environmental impact caused by the thermal energy industry. An ability to reduce the pollutants, which can be achieved using devices for converting solar radiation into the heat, was determined in this paper. The environmental effect, discussed in the present work, is caused by reducing the demand for domestic water heating. This effect results from the application of thermal solar collectors. The amount of pollutants that are released into the air, emitted from combustion of fuels, was estimated on the basis of the annual energy gain from the solar radiation and emission factors of the selected pollutants recommended by the European Environment Agency (EEA). Net gain of energy from solar panels was determined on the basis of experimental data. The object of the study was the solar domestic hot water (SDHW) system located on the roof of the Hotel for the staff of Bialystok University of Technology (Poland). Experimental studies were carried out under the project financed by the Regional Operational Program of Podlasie Province – stage 1.1 named “Study of the effectiveness of active and passive methods to improve the energy efficiency of infrastructure supported by renewable energy sources”. The construction of the research object was the target of the stage – 5.2 named “Improving the energy efficiency of Bialystok University of Technology infrastructure by use of renewable energy sources” (V. Development of environmental protection infrastructure”). The system consists of two parallel-connected installations. The first includes 21 tube collectors with a total gross area of more than 74 m2. The second unit consists of 35 flat plate collectors with a total gross area of about 72 m2. Eight storage tanks with the capacity of 1000 liters each were placed in the basement of the Hotel. The monitoring system was used to record the installation parameters during its operation. It consists of 17 heat meters, 4 electricity recorders, and 42 platinum resistance temperature sensors. The weather station that captures the basic parameters of outside air and insolation is located near the solar collectors. As a result of studies, it was found that the solar system produced 230.61 GJ heat energy throughout the year. The equation necessary to determine an equivalent amount of energy that is produced in a power plant was presented in this paper. Subsequently, the value of a possible reduction of selected pollutant emissions, which are released into the air, was calculated. Moreover, ΔPj coefficients were proposed for determination of the emissions reduction related to 1 m2 gross area of a solar panel. The main conclusions from the assessment of the impact of applying SDHW system to reduce the air pollution in the urban area were presented at the end of the paper.
Źródło:
Rocznik Ochrona Środowiska; 2016, Tom 18, cz. 2; 284-293
1506-218X
Pojawia się w:
Rocznik Ochrona Środowiska
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-6 z 6

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies