Tytuł:
Supporting the Coagulation Process with Shale – Preliminary Studies
Wspomaganie koagulacji łupkiem ilastym – badania wstępne
Autorzy:
Jabłońska, B.
Powiązania:
https://bibliotekanauki.pl/articles/1813643.pdf
Data publikacji:
2018
Wydawca:
Politechnika Koszalińska. Wydawnictwo Uczelniane
Tematy:
water treatment
coagulation
turbidity
shale
oczyszczanie wody
koagulacja
mętność
łupki ilaste
Opis:
In the paper, clayey gangue (shale) accompanying coal beds was considered to support the coagulation process. The raw shale from a mine located in the southern part of Poland as well as the shale calcined at temperatures of 600°C and 800°C were tested. The coagulant was aluminum sulfate. The effects of turbidity reduction in water samples taken from the river Warta were analyzed. Aiding the process of coagulation with the raw shale increased the efficiency of reducing turbidity in water in comparison with the use of coagulant alone. The turbidity reduction was highest when using the shale calcined at 600°C. Applying the shale calcined at 800°C brought slightly worse results, and in some cases the turbidity reduction was lower than for the raw shale. The results indicate that the shale could be an effective adjuvant in the coagulation process. In addition, previous research (Jabłońska, B., Siedlecka, E., Removing heavy metals from wastewaters with use of shales accompanying the coal beds, Journal of Environmental Management, 155 (2015), 58-66) has shown that shale has relatively good adsorptive properties, which may further contribute to the quality of the treated water.
W pracy rozważono możliwości zastosowania płonnych skał ilastych (łupków ilastych) z kopalni węgla kamiennego do wspomagania procesu koagulacji. Badano surowe i kalcynowane w temperaturze 600°C i 800°C łupki ilaste towarzyszące pokładom węgla kamiennego z kopalni położonej w południowej części Polski. Jako koagulantu użyto siarczanu glinu. Analizowano efekty obniżenia mętności w próbkach wody pobranej z rzeki Warty. Wspomaganie procesu koagulacji łupkiem surowym przyniosło większą efektywność zmniejszenia mętności w wodzie niż w przypadku zastosowania samego tylko koagulantu. Efektywność obniżania mętności była najwyższa w przypadku zastosowania łupka kalcynowanego w temperaturze 600°C. Użycie łupka kalcynowanego w temperaturze 800°C przynosiło nieco gorsze rezultaty, w niektórych przypadkach efektywność obniżania mętności była niższa niż z użyciem łupka surowego. Wyniki badań wskazują, że proces koagulacji może być efektywnie wspomagany łupkami ilastymi. Wcześniejsze badania (Jabłońska, B., Siedlecka, E., Removing heavy metals from wastewaters with use of shales accompanying the coal beds, Journal of Environmental Management, 155 (2015), 58-66) wykazały, że łupki ilaste mają stosunkowo dobre właściwości sorpcyjne, co może dodatkowo pozytywnie wpływać na jakość oczyszczanej wody.
Źródło:
Rocznik Ochrona Środowiska; 2018, Tom 20, cz. 1; 780-792
1506-218X
Pojawia się w:
Rocznik Ochrona Środowiska
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Usuwanie azotu amonowego z wód podziemnych w procesie dwustopniowej biofiltracji na złożach chalcedonitowych
Removal of ammonia nitrogen from groundwater on chalcedony deposits in two-stage biofiltration process
Autorzy:
Papciak, D.
Kaleta, J.
Puszkarewicz, A.
Powiązania:
https://bibliotekanauki.pl/articles/1819099.pdf
Data publikacji:
2013
Wydawca:
Politechnika Koszalińska. Wydawnictwo Uczelniane
Tematy:
usuwanie azotu
wody podziemne
biofiltracja
water treatment
biofiltration
Opis:
This paper presents an evaluation of the effectiveness of the removal of ammonia nitrogen from the water with oversize content of iron and manganese. The study was conducted using a two-stage biofiltration process on chalcedony beds. Biofilters operated in series, with counter-gravity flow at the first stage and the second stage gravity biofiltration. The chalcedony bed working at first stage was pre-activated with 0,3% KMnO4 in order to increase the efficiency of manganese removal. The test system was supplied with model solution made on the basis of a tap water with the addition of iron(II) 1g Fe/m3, manganese(II) 1 g Mn/m3, and ammonium 1,15-3,6 g N/m3 The results obtained during the study confirm that the biological processes of water treatment using a two-stage biofiltration through the chalcedony bed are effective in the removal of ammonia nitrogen from groundwater. Despite the diversification of mechanisms to remove these pollutants, the results indicate that the removal of ammonia nitrogen and manganese from water are competitive processes. The presence of manganese affects on the process of nitrification and ammonia nitrogen removal efficiency, and nitrification process may interfere with the effectiveness of manganese removal from water during formation of nitrification deposits. It was found that the presence of both iron and manganese affects the efficiency of the removal of ammonium and formation time of biofilm. Chemical activation biofilter of first stage had an impact on the efficiency of removal of ammonium and manganese ions, and the analysis of content of these pollutants shows that up to 10 day the chemical oxidation processes were dominated in working bed. It is difficult, however, explain the fact that in the second step of biofiltration manganese was removed with high efficiency from the outset of experiment, despite the lack of chemical activation. Previous studies have shown little effectiveness in removing manganese on the type chalcedony. A single-stage of biofiltration used in study was insufficient to carry out the nitrification process and obtain potable water for human consumption. After the first stage biofiltration water did not satisfy the requirements in terms of nitrite, and manganese. The increase in contact time through the use of second-stage of biofiltration allowed to obtain water that meets all the requirements for drinking water. Time for nitrifying chalcedony biofilter to reach full capacity was 64 days. The balance of nitrogen compounds and oxygen consumption shows the complexity of biofiltration. The real oxygen consumption was significantly lower than suggested by stoichiometric calculations and amounted to about 2 mg O2/dm3 per each mg of nitrogen removed, which can suggest that the removal of ammonia nitrogen on researched bed can occur not only in the process of nitrification. The Anammox process as well as the assimilation may have the contribute in the removal of ammonia nitrogen in the biofiltration process.
Źródło:
Rocznik Ochrona Środowiska; 2013, Tom 15, cz. 2; 1352-1366
1506-218X
Pojawia się w:
Rocznik Ochrona Środowiska
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Removal of Organic Matter from Water During the Biofiltration Process – a Full Scale Technological Investigation
Usuwanie związków organicznych z wody w procesie biofiltracji – badania w skali technicznej
Autorzy:
Kołaski, Piotr
Wysocka, Agnieszka
Pruss, Alina
Lasocka-Gomuła, Iwona
Michałkiewicz, Michał
Cybulski, Zefiryn
Powiązania:
https://bibliotekanauki.pl/articles/1812068.pdf
Data publikacji:
2019
Wydawca:
Politechnika Koszalińska. Wydawnictwo Uczelniane
Tematy:
biologically active carbon filters
filtration
full scale technical investigation
identification of microorganisms
organic matter
water treatment
biologicznie aktywne filtry węglowe
badania w skali technicznej
filtracja
oczyszczanie wody
związki organiczne
identyfikacja mikroorganizmów
Opis:
The research was carried out on the full scale Water Treatment Plant with maximal capacity of 150 000 m3/d. Treated water is characterized by a high content of organic pollutants. In order to eliminate them from water and ensure the biological stability of water in the water supply network, in January 2015 a second stage of water treatment was launched, based on integrated ozonation and filtration through carbon filter beds. Between January and May 2016, samples of water and a filter bed were collected from four carbon filters and then physicochemical and bacteriological analysis were done. The FDA test and biochemical diagnostics were made to prove the microbiological activity of the filter bed. The studies showed a decrease in the content of organic compounds, meassured as TOC and COD (KMnO4), and the biological activity of the analyzed carbon filters. The carbon filter beds were populated by Pseudomonas fluorescens, Acinetobacter lwoffii, Aeromonas salmonicida and Sphingomonas paucimobilis. In none of the analyzed filters were found strains of the Enterobacteriaceae family which may have a potential threat to health of the consumers. The application of carbon filters has reduced the organic matter content in treated water.
Badania prowadzono w skali technicznej na Stacji Uzdatniania Wody (SUW) o maksymalnej wydajności 150 000 m3/d. Woda dopływająca do SUW charakteryzuje się zawartością specyficznych zanieczyszczeń organicznych. W celu ich eliminacji z wody oraz zapewnienia biologicznej stabilności wody w sieci wodociągowej, w styczniu 2015 r. uruchomiono drugi stopień oczyszczania wody, oparty o zintegrowane procesy ozonowania i filtracji przez złoże węglowe. Co miesiąc, w okresie od stycznia do maja 2016 r., pobierano próbki wody oraz złoża filtracyjnego z czterech filtrów węglowych. Próbki wody pobierano bezpośrednio znad złoża filtracyjnego oraz na odpływie z filtrów. Próbki złoża filtracyjnego pobierano z jego górnej warstwy, w pięciu punktach każdej komory filtracyjnej. Przeprowadzono analizy fizyczno-chemiczne i bakteriologiczne wody oraz złóż filtracyjnych. W celu wykazania aktywności mikrobiologicznej złóż wykonywano test aktywności esteraz z dwuoctanem fluoresceiny FDA. W próbkach wody i węgla aktywnego w celu zidentyfikowania mikroorganizmów prowadzono diagnostykę biochemiczną z wykorzystaniem zautomatyzowanego systemu Vitek 2 Compact (bioMerieux). Przeprowadzone badania wykazały obniżenie zawartości związków organicznych wyrażonych jako OWO i ChZT (KMnO4) oraz biologiczną aktywność analizowanych filtrów węglowych. Złoża filtrów węglowych zasiedlone były przez Pseudomonas fluorescens, Acinetobacter lwoffii, Aeromonas salmonicida oraz Sphingomonas paucimobilis. W żadnym z analizowanych filtrów nie wyhodowano natomiast szczepów z rodziny Enterobacteriaceae stanowiących potencjalne zagrożenie dla zdrowia konsumentów.Wprowadzenie filtrów węglowych do ciągu technologicznego SUW spowodowało obniżenie zawartości materii organicznej w wodzie uzdatnionej.
Źródło:
Rocznik Ochrona Środowiska; 2019, Tom 21, cz. 2; 1136-1155
1506-218X
Pojawia się w:
Rocznik Ochrona Środowiska
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-3 z 3

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies