Surface probes for building materials moisture measurement by reflectometric method
Sondy powierzchniowe do pomiarów wilgotności materiałów budowlanych metodą reflektometryczną
Autorzy:
Jedut, A.
Suchorab, Z.
Sobczuk, H.
Powiązania:
https://bibliotekanauki.pl/articles/126528.pdf
Data publikacji:
2010
Wydawca:
Towarzystwo Chemii i Inżynierii Ekologicznej
Tematy:
TDR method
surface probes
moisture measurement
metoda TDR
sondy powierzchniowe
pomiary wilgotności
Opis:
The problem of building materials moisture, resulting from their porous structure, has a meaningful value for environmental engineering for the sake of its numerous, negative consequences. After breaking the limited states, the negative aspects both for building users’ health, mechanical, physical and chemical properties of barriers can be observed. Therefore, the essential matter is to provide the possibility of barriers moisture state evaluation. Among the techniques used for building materials moisture measurement, the TDR method application should be underlined for the sake of its simplicity in use and high precision, especially with the use of surface probes. The construction of probes presented in this paper enables non-invasive and accurate moisture measurements, both in laboratory and in situ conditions. The formulas obtained from conducted investigations make possible the evaluation of selected building materials moisture states.
Problem zawilgocenia materiałów budowlanych, wynikający z ich porowatej struktury, ma duże znaczenie dla inżynierii środowiska z uwagi na jego liczne, negatywne następstwa. Przy przekroczeniu stanów dopuszczalnych obserwuje się niekorzystne skutki dla zdrowia użytkowników budynku spowodowane wzrostem liczby szkodliwych mikroorganizmów i grzybów oraz obniżeniem parametrów komfortu cieplnego, a także negatywny wpływ wilgoci na właściwości mechaniczne i fizykochemiczne przegrody. Ważną kwestię stanowi zatem możliwość oszacowania stanu wilgotnościowego materiałów budowlanych. Spośród dostępnych technik pomiarowych dużą precyzją oraz prostotą stosowania wyróżnia się metoda reflektometrii w domenie czasowej (Time Domain Reflectometry), szczególnie z zastosowaniem sond powierzchniowych. Sondy o konstrukcji przedstawionej w tej pracy umożliwiają bezinwazyjne i dokładne pomiary wilgotności zarówno w warunkach laboratoryjnych, jak i w obiektach rzeczywistych. Równania otrzymane na podstawie przeprowadzonych badań mogą posłużyć do oceny stanów wilgotnościowych wybranych materiałów budowlanych.
Źródło:
Proceedings of ECOpole; 2010, 4, 1; 61-66
1898-617X
2084-4557
Pojawia się w:
Proceedings of ECOpole
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Examination of capillary rise phenomenon in aerated concrete block using the surface TDR probe
Badanie zjawiska podciągania kapilarnego w bloczku z betonu komórkowego z zastosowaniem powierzchniowej sondy TDR
Autorzy:
Suchorab, Z.
Sobczuk, H.
Pavlik, Z.
Powiązania:
https://bibliotekanauki.pl/articles/126151.pdf
Data publikacji:
2011
Wydawca:
Towarzystwo Chemii i Inżynierii Ekologicznej
Tematy:
capillary rise
aerated concrete
surface probes TDR
podciąganie kapilarne
beton komórkowy
powierzchniowe sondy TDR
Opis:
Aerated concrete is the basic building material applied in traditional building industry. It is mainly caused by its thermal parameters - heat conductivity coefficient λ for lighter brands of this material is many times lower than other traditional materials like brick etc. Low value of heat conductivity coefficient is mainly caused by the material structure which is highly porous. This porosity causes capillary forces which are the reason of so called capillary rise phenomenon being the reason of many buildings destruction. This article presents the possibility of monitoring and quantitative valuation of moisture increase in building barriers due to capillary rise with the application of the TDR surface probes enabling quick and noninvasive moisture determination in porous building materials. The analyses conducted using surface TDR probes will be compared with the examinations made using other electrical methods and the results will be presented in the form of moisture profiles changing in time.
Beton komórkowy jest podstawowym materiałem budowlanym stosowanym w budownictwie tradycyjnym. Wynika to głównie z jego właściwości termoizolacyjnych - współczynnik przewodzenia ciepła λ dla lżejszych jego odmian jest wielokrotnie niższy od wartości tego współczynnika takich materiałów, jak cegła itp. Niska wartość współczynnika przewodzenia ciepła wynika głównie ze struktury materiału, która charakteryzuje się dużą porowatością. Z właściwością tą wiąże się fakt występowania sił kapilarnych, które są przyczyną zjawiska podciągania kapilarnego będącego przyczyną destrukcji wielu budynków dotkniętych nadmiernym zawilgoceniem. Artykuł przedstawia możliwość monitoringu i ilościowej oceny wzrostu wilgotności w przegrodach budowlanych wskutek procesu podciągania kapilarnego przy wykorzystaniu powierzchniowych sond TDR umożliwiających szybkie i bezinwazyjne wyznaczanie wilgoci w porowatych materiałach budowlanych. Analizy wykonane za pomocą sond powierzchniowych porównano z wynikami z innych metod elektrycznych i przedstawiono w postaci profili wilgotnościowych zmieniających się w czasie.
Źródło:
Proceedings of ECOpole; 2011, 5, 1; 115-120
1898-617X
2084-4557
Pojawia się w:
Proceedings of ECOpole
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Examination of capillary rise phenomenon in aerated concrete block using the surface TDR probe
Badanie zjawiska podciągania kapilarnego w bloczku z betonu komórkowego z zastosowaniem powierzchniowej sondy TDR
Autorzy:
Suchorab, Z.
Sobczuk, H.
Pavlik, Z.
Powiązania:
https://bibliotekanauki.pl/articles/126745.pdf
Data publikacji:
2011
Wydawca:
Towarzystwo Chemii i Inżynierii Ekologicznej
Tematy:
capillary rise
aerated concrete
surface probes TDR
podciąganie kapilarne
beton komórkowy
powierzchniowe sondy TDR
Opis:
Aerated concrete is the basic building material applied in traditional building industry. It is mainly caused by its thermal parameters - heat conductivity coefficient λ for lighter brands of this material is many times lower than other traditional materials like brick etc. Low value of heat conductivity coefficient is mainly caused by the material structure which is highly porous. This porosity causes capillary forces which are the reason of so called capillary rise phenomenon being the reason of many buildings destruction. This article presents the possibility of monitoring and quantitative valuation of moisture increase in building barriers due to capillary rise with the application of the TDR surface probes enabling quick and noninvasive moisture determination in porous building materials. The analyses conducted using surface TDR probes will be compared with the examinations made using other electrical methods and the results will be presented in the form of moisture profiles changing in time.
Beton komórkowy jest podstawowym materiałem budowlanym stosowanym w budownictwie tradycyjnym. Wynika to głównie z jego właściwości termoizolacyjnych - współczynnik przewodzenia ciepła λ dla lżejszych jego odmian jest wielokrotnie niższy od wartości tego współczynnika takich materiałów, jak cegła itp. Niska wartość współczynnika przewodzenia ciepła wynika głównie ze struktury materiału, która charakteryzuje się dużą porowatością. Z właściwością tą wiąże się fakt występowania sił kapilarnych, które są przyczyną zjawiska podciągania kapilarnego będącego przyczyną destrukcji wielu budynków dotkniętych nadmiernym zawilgoceniem. Artykuł przedstawia możliwość monitoringu i ilościowej oceny wzrostu wilgotności w przegrodach budowlanych wskutek procesu podciągania kapilarnego przy wykorzystaniu powierzchniowych sond TDR, umożliwiających szybkie i bezinwazyjne wyznaczanie wilgoci w porowatych materiałach budowlanych. Analizy wykonane za pomocą sond powierzchniowych porównano do wyników z innych metod elektrycznych i przedstawiono w postaci profili wilgotnościowych zmieniających się w czasie.
Źródło:
Proceedings of ECOpole; 2011, 5, 2; 443-448
1898-617X
2084-4557
Pojawia się w:
Proceedings of ECOpole
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Monitoring of capillary rise phenomenon in calcium silicate board using the surface TDR probes set
Monitoring procesu podciągania kapilarnego w silikacie wapiennym za pomocą powierzchniowych sond TDR
Autorzy:
Suchorab, Z.
Powiązania:
https://bibliotekanauki.pl/articles/127144.pdf
Data publikacji:
2014
Wydawca:
Towarzystwo Chemii i Inżynierii Ekologicznej
Tematy:
capillary rise
calcium silicate
surface probes TDR
monitoring
podciąganie kapilarne
autoklawizowany silikat wapienny
powierzchniowe sondy TDR
Opis:
Capillary rise phenomenon is a process threatening many building objects. It is mainly caused by the capillary structure of most building materials. The described phenomenon relies on water flow against gravity forces and hydrostatic pressure. The problem of capillary uptake is especially visible in case of lack of horizontal or vertical water isolation layers, their damage or natural wear during long time exploitation. The sufficient condition for capillary rise phenomenon appearance is constant contact of the building barriers to the moist ground. Described phenomenon is dangerous because the range of its influence can reach even 2.5 m or more above ground level, depending on building material. Capillary uptake is a dangerous process, because it runs to barriers destruction and decrease of its strength and heat parameters. Excessive water is the reason of biological strokes of the buildings, mainly caused by mould. The article presents the experimental research of capillary rise phenomenon in a sample of autoclaved calcium silicate. For the experiment it is applied the setup of TDR sensors prototypes which enable constant monitoring of the described phenomenon in non-invasive way.
Podciąganie kapilarne jest procesem dotykającym wiele obiektów budowlanych. Przyczyną jego występowania jest kapilarna struktura większości materiałów budowlanych. Zjawisko to polega na przepływie wody w kierunku niezgodnym z siłami grawitacji, wbrew ciśnieniu hydrostatycznemu. Omawiany problem podciągania kapilarnego jest szczególnie widoczny w przypadku braku poziomych i pionowych izolacji przeciwwilgociowych, ich uszkodzenia lub przy naturalnym ich zużyciu w czasie wieloletniej eksploatacji. Warunkiem wystarczającym do rozpoczęcia procesu podciągania kapilarnego wody do wyższych partii ścian jest styczność przegród budowlanych z gruntem o naturalnej wilgotności. Zjawisko to jest niezwykle niebezpieczne, ponieważ zasięg jego oddziaływania może osiągać nawet wysokość do 2,5 m od poziomu gruntu lub więcej w zależności od materiału budowlanego. Podciąganie kapilarne jest procesem szkodliwym, ponieważ prowadzi do degradacji przegrody, obniża jej właściwości konstrukcyjne oraz cieplne. Nadmierna ilość wody w przegrodzie jest przyczyną porażeń biologicznych budynków, z których najczęściej spotykanym problemem jest zagrzybienie. W artykule przedstawiono badania eksperymentalne procesu podciągania kapilarnego w próbce z autoklawizowanego silikatu wapiennego. Do badań zastosowano zestaw prototypowych czujników TDR, dzięki którym możliwy jest ciągły monitoring zjawiska w sposób bezinwazyjny.
Źródło:
Proceedings of ECOpole; 2014, 8, 1; 82-86
1898-617X
2084-4557
Pojawia się w:
Proceedings of ECOpole
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-4 z 4

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies