Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "industrial wastewater treatment" wg kryterium: Wszystkie pola


Wyświetlanie 1-4 z 4
Tytuł:
Application of Fenton reagent in the textile wastewater treatment under industrial conditions
Zastosowanie odczynnika fentona do oczyszczania ścieków włókienniczych w warunkach przemysłowych
Autorzy:
Ledakowicz, S.
Bilińska, L.
Powiązania:
https://bibliotekanauki.pl/articles/126107.pdf
Data publikacji:
2012
Wydawca:
Towarzystwo Chemii i Inżynierii Ekologicznej
Tematy:
Fenton's reagent
textile wastewater
decolorization
inhibition
odczynnik Fentona
ścieki włókiennicze
odbarwianie
inhibicja
Opis:
Application of reactive dyes is very popular in textile industry as these dyestuffs are characterized by good fastness properties. Constapel et al estimated the production of this type dyes for over 140,000 Mg/year. The reactive dyes are mostly (50%) employed for coloration of cellulosic fibers, however they can be also applied on wool and nylon. Unfortunately, they possess a low degree of fixation (50÷90%), since the functional groups also bond to water, creating hydrolysis and the excess of dyes applied cause a colored pollution of aqueous environment. Moreover, dyeing process requires the use of: electrolytes in the form of aqueous solutions of NaCl or Na2SO4 in the concentration up to 100 g/dm3, alkaline environment (pH > 10) and textile auxiliary agents (among others detergents). Therefore, the wastewater generated during the reactive dyeing processes are characterized by high salinity, pH value and color, and due to low value of the ratio BOD5/COD are non-biodegradable. The successful methods of the textile wastewater treatment could be an advanced oxidation processes (AOPs), amongst which the Fenton reagent seems to be the most perspective as it is the cheapest and easy in use. Based on the newest literature survey it was found that many successful tests with Fenton reaction were performed mainly in decolorization. However, not enough attention was devoted to decolorization of real industrial wastewater containing dyes, detergents and salts NaCl, or Na2SO4. The experiments carried out in lab scale were focused on the impact of NaCl and textile auxiliary agent (liquid dispersing and sequestring agent) on an inhibition of decolorization process by Fenton reagent. The objects of the investigation were the synthetic mixtures simulating the composition of real textile wastewater as well as the real industrial wastewater generated in the reactive dyeing. The inhibition of the Fenton decolorization in the presence of NaCl and liquid dispersing and sequestering agent was demonstrated.
Barwniki reaktywne wyróżnia szereg cech, które sprawiają, iż są one powszechnie stosowane w praktyce przemysłu włókienniczego. Constapel i in. oszacowali roczną produkcję tego typu barwników na ponad 140 000 Mg. Przy czym barwniki reaktywne są w większości (50%) stosowane do barwienia włókien celulozowych, jednakże mogą one być również stosowane do wełny i poliamidu. Niestety, barwniki reaktywne wyróżnia niski stopień wyczerpania z kąpieli, wynoszący od 50 do 90%. Oznacza to, iż w przemysłowych procesach barwienia używany jest nadmiar barwnika, który nie wiąże się z włóknem i w postaci hydrolizatu trafia do ścieków, stanowiąc obciążenie dla środowiska. Procesy barwienia reaktywnego wymagają użycia elektrolitu w postaci: roztworu NaCl lub Na2SO4 o stężeniu do 100 g/l, wytworzenia silnie alkalicznego pH oraz użycia środków powierzchniowoczynnych - SPC. To sprawia, iż ścieki generowane w procesach barwienia reaktywnego charakteryzuje: wysokie zasolenie i zabarwienie, wysoka wartość pH, obecność SPC. Ponadto te ścieki ze względu na niski stosunek BZT5/ChZT są mało podatne na procesy biologicznego oczyszczania. Alternatywą dla oczyszczania tego typu ścieków mogą być metody AOP, wśród których na uwagę ze względu na niskie koszty i łatwość stosowania zasługuje odczynnik Fentona. Na podstawie przeglądu najnowszych doniesień literaturowych można stwierdzić, iż zostało przeprowadzone wiele udanych prób głównie dekoloryzacji roztworów. Niewiele natomiast uwagi poświęcono odbarwianiu ścieków rzeczywistych czy symulowanych mieszanin zbliżonych składem do ścieków rzeczywistych, czyli zawierających barwniki oraz NaCl, Na2SO4, SPC, (Sun i in. 2009; Arslan-Alaton i in. 2008). Eksperymenty przeprowadzone w skali laboratoryjnej były ukierunkowane na analizę wpływu NaCl i włókienniczych środków pomocniczych (środki dyspergujące i sekwestrujące) na hamowanie procesu odbarwiania odczynnikiem Fentona. Przedmiotem badań były zarówno syntetyczne ścieki symulujące skład rzeczywistych ścieków włókienniczych, jak również rzeczywiste ścieki powstałe w procesie barwienia reaktywnego. Wykazano zjawisko hamowania odbarwiania odczynnikiem Fentona w obecności NaCl, jak i środków dyspergujących i sekwestrujących.
Źródło:
Proceedings of ECOpole; 2012, 6, 1; 13-20
1898-617X
2084-4557
Pojawia się w:
Proceedings of ECOpole
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Modyfikacja cyklu pracy sekwencyjnego bioreaktora membranowego podczas oczyszczania ścieków przemysłowych
Modification work cycle phases duration of treatment of industrial wastewater in the sequential membrane bioreactor
Autorzy:
Świerczyńska, A.
Bohdziewicz, J.
Powiązania:
https://bibliotekanauki.pl/articles/127437.pdf
Data publikacji:
2015
Wydawca:
Towarzystwo Chemii i Inżynierii Ekologicznej
Tematy:
ścieki z przemysłu mleczarskiego
odcieki składowiskowe
SBR
bioreaktor membranowy
dairy wastewater
landfill leachate
membrane bioreactor
Opis:
Celem badań było ustalenie najkorzystniejszego czasu prowadzenia faz w cyklu pracy sekwencyjnego bioreaktora membranowego w procesie współoczyszczania ścieków przemysłowych, wpływającego na zmniejszenie głównie stężenia fosforu fosforanowego. Układ badawczy składał się z bioreaktora membranowego z zainstalowanym wewnątrz modułem membranowym oraz zbiornika uśredniającego. Udział odcieków wynosił 10% obj. Osad nadmierny na bieżąco usuwano z reaktora SBR w celu utrzymania stałego stężenia na poziomie 3,5 g/dm3. Obciążenie osadu ładunkiem zanieczyszczeń wynosiło 0,06 g ChZT/g s.m. d, a stężenie tlenu kształtowało się na poziomie 3 mg/dm3. Bioreaktor membranowy pracował w dwóch cyklach na dobę. Faza mieszania z napełnianiem trwała 4 h, napowietrzanie 7 h, sedymentacja 30 min, odprowadzenie sklarowanych ścieków 30 min. Następnie po 4 tygodniach pracy w tych warunkach zmodyfikowano cykl pracy sekwencyjnego bioreaktora membranowego poprzez skrócenie ich przebiegu oraz wprowadzenie dodatkowych dwóch faz denitryfikacji i nitryfikacji. Czas prowadzenia poszczególnych faz pracy bioreaktora był następujący: napełnianie wynosiło 10 min z równoczesnym mieszaniem, trwającym łącznie 3 h, napowietrzanie 4 h, mieszanie 1 h, napowietrzanie 3 h, sedymentacja 30 min i dekantacja oczyszczonych ścieków 30 min. Analizując otrzymane wyniki, wykazano poprawę efektywności współoczyszczania badanej mieszaniny ścieków po wprowadzeniu zmian w cyklach pracy bioreaktora membranowego. Wprowadzone zmiany czasów poszczególnych faz procesowych reaktora MSBR spowodowały obniżenie stężenia P-PO4 3– z 4,8 do wartości 2,9 mg/dm3.
The aim of presented study which was associated with modification of the various work cycle phases duration in the membrane bioreactor, was to reduce the concentration of phosphate phosphorus during the leachate co-treatment with dairy wastewater. The experimental set-up was comprised of the membrane bioreactor equipped with the immersed membrane module installed inside the reactor chamber, and the equalization tank. During the co-treatment experiment performance the excessive activated sludge was constantly removed from the membrane bioreactor in order to keep its concentration at 3.5 g/dm3. The load of the sludge with the contaminants was equal to 0.06 g COD/g d.m. d. The concentration of oxygen was equal to 3 mg/dm3. The share of the leachates in the co-treated mixture was equal to 10% vol. The membrane bioreactor worked as the sequential biological reactor, in two cycles per day. Duration of each phase was equal as follows: filling - 10 mins - with concurrent mixing phase lasting for 4 hrs, aeration phase - 1 hr, sedimentation - 30 mins and removal from purified wastewater - 30 mins. After 4 weeks under these conditions, the modification of the sequential membrane bioreactor’s work cycle was made. Duration of particular phases was shortened and two phases of denitrification and nitrification were introduced. Work cycle phases were modified as follows: filling - 10 mins - with concurrent mixing phase lasting for 3 hrs, aeration phase - 4 hrs, mixing phase - 1 hr, aeration phase - 3 hrs, sedimentation - 30 mins and removal from purified wastewater - 30 mins. Based on research, it was found that the change in membrane bioreactors’s work cycle affect effectiveness of treated mixture. Alteration of MSBR reactor particular phases duration caused reduction of concentration of P-PO4 3– from 4.8 to 2.9 mg/dm3.
Źródło:
Proceedings of ECOpole; 2015, 9, 1; 333-338
1898-617X
2084-4557
Pojawia się w:
Proceedings of ECOpole
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Dewatering of sludge from electroplating wastewater treatment
Odwadnialność osadów pochodzących z oczyszczania ścieków galwanicznych
Autorzy:
Płonka, I.
Pieczykolan, B.
Kosel, M.
Powiązania:
https://bibliotekanauki.pl/articles/126074.pdf
Data publikacji:
2015
Wydawca:
Towarzystwo Chemii i Inżynierii Ekologicznej
Tematy:
sludge from industrial
mechanical dewatering
choice of polyelectrolyte
osady ściekowe z przemysłu
odwadnianie mechaniczne
dobór polielektrolitu
Opis:
Electroplating coating of products more sustainable coatings is their protection or decoration. As a result of these technological processes generated waste water, which are treatment. During the treatment of waste water produced sludge that were the subject of research. Sludge were from wastewater treatment plants located at the manufacturing plant which produces car parts. They were taken from the sludge tank, preceded by sedimentation in the lamella. In order to determine their sensitivity to dewatering the first step was selected the type and dose of reagent. In the second stage of the study conditioned sludge were tested mechanical dewatering centrifuge and belt press simulator. The results obtained showed that the most effective effect was observed when using anionic polyelectrolytes Praestol 2505 and Superfloc A 110 and A 130. Were used in a dose of 2.1 mg/g TS to 3.4 mg/g TS, and from 8.2 mg/g TS to 15.4 mg/g TS. The use of too low a dose of reagent and overdose resulted in unsatisfactory conditioning effects. The excess polyelectrolyte increased viscosity of the liquid sludge, which gave slower water contained therein. Conditioned selected polyelectrolytes sludge were subjected to a mechanical dewatering. The sludge obtained after centrifugation is characterized by a total solids a maximum of 12.7%. The centrifugation process efficiency was influenced by the spin speed and the duration of the process. The best results were obtained for a duration of 10 min and a speed of 3000 turns/min. A higher degree of dewatering of 29.5% TS obtained using the simulator of belt press.
Galwaniczne pokrywanie wyrobów trwalszymi powłokami stanowi ich ochronę lub dekorację. W wyniku tych procesów powstają ścieki technologiczne, które są oczyszczane. Podczas oczyszczania ścieków powstają osady, które stanowiły przedmiot badań. Osady pochodziły z oczyszczalni ścieków znajdującej się przy zakładzie produkującym części samochodowe. Zostały pobrane ze zbiornika szlamowego, poprzedzonego sedymentacją w osadniku lamelowym. W celu określenia ich podatności na odwadnianie w pierwszym etapie dokonano doboru rodzaju i dawki polieletrolitu. W drugim etapie badań kondycjonowane osady poddano próbom mechanicznego odwadniania w wirówce oraz symulatorze prasy taśmowej. Uzyskane wyniki badań wykazały, że najskuteczniejszy wpływ zaobserwowano w przypadku zastosowania polielektrolitów anionowych Praestol 2505 oraz Superfloc A 110 i A 130. W badaniach zastosowano dawki od 2,1 do 3,4 mg/g s.m. oraz od 8,2 do 15,4 mg/g s.m. Zastosowanie zarówno zbyt małej dawki reagenta, jak i przedawkowanie doprowadziło do uzyskania niezadowalających efektów kondycjonowania. Nadmiar polielektrolitu zwiększył lepkość cieczy osadowej, przez co osad wolniej oddawał zawartą w nim wodę. Kondycjonowane wybranymi polielektrolitami osady zostały poddane procesowi mechanicznego odwadniania. W wyniku wirowania otrzymano osad charakteryzujący się zawartością suchej masy maksymalnie 12,7%. Na efektywność procesu odwirowania miała wpływ prędkość wirowania oraz czas trwania procesu. Najlepsze efekty uzyskano dla czasu wynoszącego 10 min oraz prędkości 3000 obr/min. Wyższy stopień odwodnienia wynoszący 29,5% s.m. uzyskano przy zastosowaniu symulatora pracy taśmowej.
Źródło:
Proceedings of ECOpole; 2015, 9, 1; 125-132
1898-617X
2084-4557
Pojawia się w:
Proceedings of ECOpole
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Modelowanie wydajności procesu ultrafiltracyjnego oczyszczania ścieków koksowniczych z zastosowaniem membran komercyjnych
Modeling of ultrafiltration process efficiency in treatment coke plant wastewater with use industrial membranes
Autorzy:
Mielczarek, K.
Kwarciak-Kozłowska, A.
Bohdziewicz, J.
Korus, I.
Powiązania:
https://bibliotekanauki.pl/articles/127380.pdf
Data publikacji:
2009
Wydawca:
Towarzystwo Chemii i Inżynierii Ekologicznej
Tematy:
ultrafiltracja
ścieki koksownicze
ciśnieniowe techniki membranowe
modelowanie wydajności procesu ultrafiltracji
ultrafiltration
coke plant wastewater
high pressure membrane techniques
commercial membranes
Opis:
Przedstawiono efektywność procesu oczyszczania poprocesowych wód koksowniczych w układzie zintegrowanym ultrafiltracja-odwrócona osmoza. W procesach ciśnieniowej filtracji membranowej zastosowano polimerowe membrany amerykańskiej firmy Osmonics. Wyznaczenie na drodze doświadczalnej ultrafiltracyjnych strumieni permeatów początkowego (J0) i równowagowego (nasycenia - J∞) oraz w sposób graficzny stałej czasowej t0 umożliwiło, zgodnie z założonym modelem relaksacyjnym, przeprowadzenie obliczeń pozwalających na prognozowanie wydajności stosowanych membran.
In the article there have been presented the results of research whose aim was to determine the effectiveness of treating the coke plant wastewater in the integrated ultrafiltration - reverse osmosis system. In the process pressure membrane filtration was carried out on using the polymer membranes of an American Osmonics brand. Determining ultrafiltration initial permeat fluxes (J0) and equilibrium (saturations - J∞) on the experimental road and into the graphic way of the temporary constant (t0) enabled based on the relaxation model established, that describes, define the possibility of predicting the polysulfone ultrafiltration membranes efficiency in the process of coke industry wastewater treatment.
Źródło:
Proceedings of ECOpole; 2009, 3, 2; 483-489
1898-617X
2084-4557
Pojawia się w:
Proceedings of ECOpole
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-4 z 4

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies