Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "Radon-222" wg kryterium: Wszystkie pola


Wyświetlanie 1-2 z 2
Tytuł:
Activity concentration of radon-222 in the buildings of the Opole University
Aktywność radonu-222 w budynkach Uniwersytetu Opolskiego
Autorzy:
Narolska, J.
Piątek, M.
Dołhańczuk-Śródka, A.
Powiązania:
https://bibliotekanauki.pl/articles/127267.pdf
Data publikacji:
2014
Wydawca:
Towarzystwo Chemii i Inżynierii Ekologicznej
Tematy:
Rn-222 activity
AlphaGUARD spectrometer
Rn-222
aktywność
spektrometr AlphaGUARD
Opis:
Rn-222 activity concentration is on average several times higher in confined spaces than outside. Given that approx. 75% of the time we spend indoors, there is a need to draw attention to the activity concentration of Rn-222 in rooms in which we live. The paper presents the results of measurements of Rn-222 activity concentration in the period September-October 2014, in the buildings of the Opole University. The measurements were performed using a portable spectrometer AlphaGUARD. In the tested buildings Rn-222 activity concentrations differs in the ranged from 4 to 38 Bq/m3. These differences may be related to the local properties of the soil, the properties of the materials used in buildings construction and the method of building ventilation. The measurements of Rn-222 activity concentrations in the buildings of the Opole University showed no potential health risks resulting from radon.
Aktywność Rn-222 w pomieszczeniach zamkniętych jest średnio kilkakrotnie większa niż na zewnątrz. Ponieważ ok. 75% czasu spędzamy w pomieszczeniach zamkniętych, istnieje potrzeba zwrócenia uwagi na aktywność Rn-222 w pomieszczeniach, w których przebywamy. W pracy przedstawiono wyniki pomiarów aktywności Rn-222, w okresie wrzesień-październik 2014 r., w budynkach Uniwersytetu Opolskiego. Pomiary wykonano za pomocą przenośnego spektrometru AlphaGUARD. Zaobserwowano zróżnicowane aktywności Rn-222 w badanych budynkach, które mieściły się w przedziale od 4 do 38 Bq/m3. Różnice te mogą być związane z lokalnymi właściwościami gruntu, właściwościami wykorzystanych materiałów budowlanych, a także sposobem wentylacji. Pomiary aktywności Rn-222 w budynkach Uniwersytetu Opolskiego wykazały brak potencjalnego zagrożenia zdrowia, wynikającego z zanieczyszczenia radonem.
Źródło:
Proceedings of ECOpole; 2014, 8, 2; 423-427
1898-617X
2084-4557
Pojawia się w:
Proceedings of ECOpole
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Issues of radon (Rn-222) exhalation measurements
Problematyka pomiarów ekshalacji radonu (Rn-222)
Autorzy:
Modzelewska, D.
Dołhańczuk-Śródka, A.
Ziembik, Z.
Powiązania:
https://bibliotekanauki.pl/articles/126822.pdf
Data publikacji:
2014
Wydawca:
Towarzystwo Chemii i Inżynierii Ekologicznej
Tematy:
radon
exhalation
concentration
measurement uncertainty
AlphaGUARD
ekshalacja
stężenie
niepewność pomiarowa
Opis:
The Rn-222 isotope, a naturally occurring radioactive gas, is created in a radioactive decay of Ra-226. Both radionuclides belong to the radium decay chain in which U-238 is the prime parent. Radon is usually in plenty found in the earth crust, rocks, soil, water and air, therefore it is regarded as an indicator of ionizing radiation dose received by a population. Due to radon negative influence on people’s health, measurements of its concentration are commonly performed. The presented research concerns assessment of measurements uncertainty of Rn-222 concentration exhaled from soil. The measurements were repeated at the same site. The experiment was carried out in natural conditions, in the city center and lasted about half a year. In Rn-222 concentration measurements the AlphaGUARD radon monitor was used. The device was operating in the 10-minutes flow mode, with the air pump and exhalation-box arranged in the closed cycle. The studies have shown a significant differences between results of radon exhalation measurements, which were carried out sequentially in the same place. Generally, increase in measurements number in a series lowers the result uncertainty. Consequently, the number of measurements in a series can be adjusted to the desired uncertainty of result. What is more, the distribution of the results in series is well described by the Poisson distribution.
Izotop Rn-222, naturalnie występujący radioaktywny gaz, powstaje na skutek rozpadu promieniotwórczego Ra-226. Oba radionuklidy należą do szeregu uranowo-radowego, który rozpoczyna U-238. Radon występuje w dużych ilościach w skorupie ziemskiej, skałach, glebie, wodzie i powietrzu, dlatego jest on traktowany jako wskaźnik dawki promieniowania jonizującego otrzymywanego przez ludzi. Ze względu na negatywny wpływ radonu na zdrowie ludzi pomiary stężenia tego gazu są często wykonywane. Zaprezentowano wyniki badań niepewności pomiarowej stężenia Rn-222 w powietrzu ekshalowanym z gleby. Pomiary powtarzano wielokrotnie w tym samym miejscu. Eksperyment przeprowadzony został w warunkach naturalnych, w centrum miasta i obejmował okres około pół roku. Do pomiarów stężenia radonu wykorzystano monitor radonowy AlphaGUARD. Pracował on w 10-minutowym trybie przepływowym, z pompą oraz komorą ekshalacyjną w obiegu zamkniętym. Badania wykazały znaczne różnice pomiędzy wynikami pomiarów, wykonywanych w całym okresie badawczym. W pojedynczej serii większa liczba pomiarów zmniejsza niepewność pomiarową. Dzięki temu ilość pomiarów w serii może być dostosowana do oczekiwanej niepewności pomiarowej wyniku. Stwierdzono, że rozkład wyników aktywności radonu w serii jest dobrze opisywany przez rozkład Poissona.
Źródło:
Proceedings of ECOpole; 2014, 8, 2; 409-415
1898-617X
2084-4557
Pojawia się w:
Proceedings of ECOpole
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-2 z 2

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies