Tytuł:
Currents physical components theory and p-q power theory in the control of the three-phase shunt active power filter
Teoria składowych fizycznych prądu oraz teoria mocy p-q w zastosowaniu do sterowania równoległym energetycznym filtrem aktywnym
Autorzy:
Firlit, A.
Powiązania:
https://bibliotekanauki.pl/articles/154209.pdf
Data publikacji:
2007
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
energetyczny filtr aktywny
teorie mocy
jakość energii elektrycznej
active power filter
power theories
electric power quality
Opis:
This paper presents the comparison of the control algorithms for a three phase, three wire shunt active power filter. The control algorithms are based on: the current's physical components theory and the p-q power theory. The active power filter operation under the distorted supply voltage at the point of common coupling condition is considered. The comparison concerns the aspects of: filtering current harmonics, reactive power compensation (defined in the fundamental harmonic domain), supply current balancing and dynamic performance. The results of the laboratory investigation, using the fast prototyping system dSPACE, are given in the paper.
W artykule przedstawiono porównanie algorytmów sterowania trójfazowym, trójprzewodowym równoległym energetycznym filtrem aktywnym. Algorytmy sterowania opracowano na podstawie dwóch teorii mocy: teorii składowych fizycznych prądu oraz teorii mocy p-q. Badaniom podlegała praca energetycznego filtru aktywnego w warunkach odkształconego napięcia zasilającego w punkcie wspólnego przyłączenia. Za kryterium porównania przyjęto: filtrację wyższych harmonicznych prądu odbiornika, kompensację mocy biernej (zdefiniowanej w dziedzinie podstawowej harmonicznej), symetryzację asymetrycznych prądów linii zasilającej odbiornik oraz dynamikę energetycznego filtru aktywnego. W artykule zamieszczono wyniki pomiarów i badań otrzymane na zbudowanym stanowisku laboratoryjnym trójfazowego, trójprzewodowego równoległego energetycznego filtru aktywnego z wykorzystaniem systemu szybkiego prototypowania dSPACE.
Źródło:
Pomiary Automatyka Kontrola; 2007, R. 53, nr 3, 3; 110-115
0032-4140
Pojawia się w:
Pomiary Automatyka Kontrola
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Sterowanie przekształtnikiem równoległego filtra aktywnego ze światłowodową transmisją TOSLINK
Inverter control of paraller active power filter with TOSLINK optical transmission
Autorzy:
Kuźma, A.
Zajkowski, M.
Powiązania:
https://bibliotekanauki.pl/articles/157257.pdf
Data publikacji:
2010
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
odbiornik nieliniowy
filtr aktywny
światłowód
LED
fotodoetektor
WDM
nonlinear receiver
active power filter
optical fiber
photodetector
Opis:
Artykuł przedstawia wyniki badań równoległego filtra aktywnego poprawiającego właściwości odbiornika nieliniowego, w którym wykorzystano transmisję sygnałów sterujących łączem światłowodowym. Transmisję światłowodową zrealizowano przy wykorzystaniu układu TOTO/ TORX 173 i polimerowego włókna optycznego (POF). Dotychczasowe rozwiązania wykorzystujące klasyczne łącza miedziane sprawdzały się do transmisji na odległość tylko rzędu kilkunastu centymetrów, ze względu na bardzo duże zniekształcenia wynikające z oddziaływania zewnętrznego pola elektromagnetycznego na przewody transmisyjne. Stosując optyczne łącze światłowodowe uzyskano poprawną pracę układu z możliwością odseparowania modułów sterujących na odległość rzędu 10 m, z perspektywą wydłużenia linii transmisyjnej, wykorzystując technikę WDM.
The paper presents investigation results of the parallel active power filter, which improves the propriety of nonlinear receiver set. Control system is using the TOSLINK optical link transmission.The optical systems of data transmision usually be used in telecommunicational optical nets, audio-video connection or there, where assured the suitable quality of signal has to be. The light is insensitive on electromagnetic field, under regard his speed of changes and the value of field amplitude. This optical track proprieties can transfer information in subject to electromagnetic disturbance environments Fig. 4) [3]. The system control was executed in two ways. Technologically simpler was the system of individual input-output channels (Fig. 5). The more advanced WDM system (Fig. 6), was using the multiplexation and demultiplexation of optical signal broadcast with single fiber. The transoptors elimination from control systems and leaning in their place the optical broadcast system besed on TOTX/TORX 173 (Fig. 7) improves the quality of steering signal quality and increases the transmission band in comparison to integrated arrangements. The use of optical fiber separation permits on shortening the distance between module and inverter. The signal analysis from oscilloscope (Fig. 8) shows small delay, which results from the time of detection by TORX and insignificant disconnection time of TOTX. The test of optical link was executed by the optical fiber of length nearly 10 m.
Źródło:
Pomiary Automatyka Kontrola; 2010, R. 56, nr 2, 2; 122-124
0032-4140
Pojawia się w:
Pomiary Automatyka Kontrola
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Wpływ zmian częstotliwości napięcia sieci zasilającej na pracę hybrydowego energetycznego filtru aktywnego - analiza wrażliwości
The impact of frequency fluctuation in power lines on a hybrid active power filter - the sensitivity analysis
Autorzy:
Buła, D.
Pasko, M.
Powiązania:
https://bibliotekanauki.pl/articles/152731.pdf
Data publikacji:
2014
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
wyższe harmoniczne
hybrydowy energetyczny filtr aktywny
analiza wrażliwości
higher harmonics
hybrid active power filter
sensitivity analysis
Opis:
W pracy przedstawiono analizę wrażliwości hybrydowego energetycznego filtru aktywnego, która dotyczy wpływu zmian częstotliwości napięć sieci zasilającej na współczynnik tłumienia wyższych harmonicznych badanego układu. Na podstawie obliczonej wrażliwości przeprowadzono analizę względnych zmian współczynnika tłumienia w zależności od parametrów układu. Dla dodatkowego zobrazowania wyników analizy, pokazano przykład obliczeniowy dla układu hybrydowego z filtrem pasywnym piątej harmonicznej. Całość podsumowano wnioskami.
The sensitivity analysis of a hybrid active power filter (HAPF) is presented in the paper. Application of HAPF is one of the methods for reducing harmonics in three-phase power lines. The presented analysis concerns the impact of changes in the frequency of the mains voltage for a harmonic attenuation factor (distribution factor) of the examined system. Assuming the single-phase equivalent circuit of HAPF (Fig. 1b), first and second order sensitivity coefficients were obtained (9, 10). Subsequently, the relative changes of the distribution factor at frequency changes were determined (11). On this basis, an analysis of the impact of system parameters on the sensitivity and changes of the distribution factor was performed (Figs. 5 and 6). The analysis showed that the values of the passive filter elements and K gain affected the sensitivity of the system slightly. However, the Q-factor of the passive filter has a significant impact. Large values of the Q-factor cause that even small changes in frequency can lead to large changes in the distribution factor. Additionally, in order to illustrate the results of the analysis, the appropriate calculation example is shown in the paper.
Źródło:
Pomiary Automatyka Kontrola; 2014, R. 60, nr 11, 11; 1013-1015
0032-4140
Pojawia się w:
Pomiary Automatyka Kontrola
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-3 z 3

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies