Wyświetlanie 1-3 z 3
Tytuł:
A new method for on-line monitoring of bushings, transients and PD of power transformers
Nowe metody monitoringu on-line przepustów, przepięć i wyładowań niezupełnych transformatorów energetycznych
Autorzy:
Koch, M.
Kołtunowicz, W.
Krüger, M.
Powiązania:
https://bibliotekanauki.pl/articles/156993.pdf
Data publikacji:
2013
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
power transformers
bushings
on-line monitoring
dissipation factor
capacitance
PD
UHF
transformator energetyczny
przepust
monitoring on-line
współczynnik strat
pojemność
WNZ
Opis:
This paper describes a new on-line method for capacitance and dissipation factor measurements of high voltage bushings, for recording grid transients and for partial discharge monitoring at power transformers. The needed accuracy for reliable detection of failures is in the range of 5 pF for capacitance and 0.1 % for dissipation factor. To overcome these shortcomings, this paper introduces an absolute method for measuring capacitance and dissipation factor of HV bushings. As for off-line measurements, the discrimination between noise and true internal discharges is the key for successful diagnosis. Strategies for sensitive partial discharge measurements under disturbed on-line conditions are described, also involving measurements in the UHF range.
Artykuł opisuje nowe metody pomiaru on-line pojemności i współczynnika strat przepustów wysokonapięciowych na potrzeby, monitorowania przepięć w sieci i wyładowań niezupełnych w transformatorach energetycznych. Według statystyk awaryjności przepusty WN są jedną z głównych przyczyn awarii transformatorów, co motywuje operatorów do ciągłego monitoringu on-line stanu układów izolacyjnych. Na potrzeby wiarygodnej diagnostyki wymagana jest dokładność pomiaru pojemności rzędu 5 pF i współczynnika strat rzędu 0,1%. Aby uzyskać taką rozdzielczość, wskutek braku symetrii w sieci, nie wystarczy względne porównanie prądów mierzonych w zaciskach pomiarowych w przepustach trzech faz. Dodatkowo, ten sposób pomiaru nie pozwala identyfikować procesu starzenia przebiegającego w trzech fazach ze zbliżonym tempem. W artykule przedstawiono metodę pomiaru rzeczywistych wartości pojemności i współczynnika strat przepustów WN. Pozwala ona uzyskać dokładność podobną do pomiarów off-line nawet w warunkach eksploatacyjnych. Wyładowania niezupełne są wczesnym wskaźnikiem zbliżającego się przebicia w izolacji WN. Ich pomiar na zacisku przepustu WN umożliwia wykrycie defektów w izolacji przepustu oraz transformatora. Podobnie jak w pomiarach off-line, rozróżnienie zakłóceń od rzeczywistych wyładowań wewnętrz izolacji jest kluczem do poprawnej diagnostyki. Opisano strategie czułego pomiaru wyładowań niezupełnych w warunkach on-line, z uwzględnieniem zakresu UHF.
Źródło:
Pomiary Automatyka Kontrola; 2013, R. 59, nr 2, 2; 120-124
0032-4140
Pojawia się w:
Pomiary Automatyka Kontrola
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Analiza metrologiczna układu do ciągłej kontroli stanu izolacji obiektu
Metrological analysis of on-line electrical insulation monitoring circuit
Autorzy:
Rochiński, P.
Guzik, J.
Powiązania:
https://bibliotekanauki.pl/articles/153088.pdf
Data publikacji:
2010
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
izolacja elektryczna
ciągła kontrola stanu izolacji
electrical insulation
on-line monitoring of electrical insulation
Opis:
W pracy przedstawiono koncepcję i możliwe struktury układu do ciągłej kontroli stanu izolacji obiektu w 3-fazowej sieci uziemionej prądu przemiennego. Zaprezentowano i przeanalizowano także podstawowe właściwości metrologiczne omawianego układu (tj. jego czułość bezwzględną |S| i względną niepewność standardową urel (Ri) oszacowania wartości rezystancji izolacji Ri). Przedstawiono wyniki wybranych symulacji komputerowych, przeprowadzonych z uwzględnieniem dynamiki rezystancji upływowej.
In this paper the concept and possible two circuit structures for on-line monitoring of electrical insulation in a 3-phase AC grounded network are presented. The object of investigation is represented by leakage resistance. Increase in the leakage current value is the result of worsening the parameters characterising the investigated object electric insulation. There is shown the electrical insulation model in which the leakage resistance of a three-phase object is combination of leakage resistances of each phase. For on-line monitoring of electrical insulation (insulation resistance) of an AC object the authors used a DC signal (a source of DC voltage), while a test signal is the leakage current. Fig. 1 shows an electrical insulation monitoring circuit. For two positions of switch W (see. Fig. 1b, c) the insulation resistance values are described by Eqs. (3) and (5), respectively. Figs. 2-7 present chosen computer simulations which were carried out when taking into account the dynamics of leakage resistance. The most important metrological parameters (e.g. absolute sensitivity and insulation resistance relative standard uncertainty) of the presented circuit are analysed and presented, too. The proposed electrical insulation monitoring circuit makes the continuous insulation resistance measurement in a rough way (circuit structure of Fig. 1c) and exact way (circuit structure of Fig. 1b) possible with use of the standard resistance Rp. The insulation resistance measure-ment accuracy and linearity of the circuit transfer characteristics were good (see Figs. 3 - 5). The sensitivity of the presented insulation resistance monitoring circuit is high and directly propor-tional to the applied voltage value Eg.
Źródło:
Pomiary Automatyka Kontrola; 2010, R. 56, nr 11, 11; 1274-1276
0032-4140
Pojawia się w:
Pomiary Automatyka Kontrola
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Estimation of equivalent power system impedance in normal conditions
Wyznaczanie impedancji zastępczej systemu elektroenergetycznego w warunkach normalnych
Autorzy:
Małyszko, O.
Nowakowski, R.
Zeńczak, M.
Powiązania:
https://bibliotekanauki.pl/articles/156976.pdf
Data publikacji:
2007
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
system elektroenergetyczny
moc zwarciowa
impedancja zastępcza
monitoring
power system
short-circuit power
equivalent impedance
on-line control
Opis:
The paper presents method of estimation of equivalent power system impedance. The method based on the correlation method which uses natural variability of the voltage level in the network nodes. To find the value of equivalent power system resistance and reactance the Lyapunov exponents were used. Equivalent impedance of power system is the base to determination of short-circuit currents and short-circuit power. On-line control over the short-circuit power in key nodes of power system might provide system dispatchers with an important piece of information.
Ważnym parametrem systemu elektroenergetycznego (SEE) jest poziom mocy zwarciowej w poszczególnych węzłach. Znajomość wartości mocy zwarciowej pozwala na określenie wartości spodziewanych prądów zwarciowych. Jest to niezbędne do prawidłowego doboru urządzeń w fazie projektowania systemu oraz do doboru nastaw automatyki zabezpieczeniowej. Moc zwarciowa zależy od impedancji zastępczej SEE. Wartość tej impedancji zależy od liczby generatorów, transformatorów, linii elektroenergetycznych oraz ich mocy, impedancji i układu połączeń między nimi. Wartość tej impedancji nie jest wielkością stałą w czasie. Zmiany mogą wynikać zarówno ze zmiany układu połączeń w systemie (zmiany krótkookresowe) jak też z rozwoju SEE (zmiany długookresowe). W artykule przedstawiono koncepcję wyznaczania impedancji zastępczej SEE w warunkach ruchowych. Przedstawiona metoda bazuje na zmienności poziomu napięcia w węzłach pomiarowych SEE spowodowanej przez losowe zmiany prądu obciążenia wynikające z losowej zmiany obciążenia. Zgodnie z proponowaną metodą do wyznaczenia impedancji systemu konieczny jest pomiar wartości skutecznej prądu, napięcia, mocy czynnej i dodatkowo wyznaczenie sumy wykładników Lapunowa.
Źródło:
Pomiary Automatyka Kontrola; 2007, R. 53, nr 6, 6; 11-13
0032-4140
Pojawia się w:
Pomiary Automatyka Kontrola
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-3 z 3

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies