Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "glottis" wg kryterium: Temat


Wyświetlanie 1-4 z 4
Tytuł:
Phonatory compensation in patients with larynx cancer after CO2 laser cordectomy
Autorzy:
Kosztyła-Hojna, Bożena
Łuczaj, Jarosław
Berger, Greta
Duchnowska, Emilia
Zdrojkowski, Maciej
Łobaczuk-Sitnik, Anna
Biszewska, Jolanta
Powiązania:
https://bibliotekanauki.pl/articles/1397494.pdf
Data publikacji:
2020
Wydawca:
Index Copernicus International
Tematy:
cordectomy
glottis cancer
high speed digital imaging
laryngeal compensation
Opis:
Introduction: CO2 laser endoscopic cordectomy is the method of laryngeal cancer treatment. The type of cordectomy (I–VI) depends on the extent of the tumor. Endoscopic laser surgery provides more satisfactory phonation conditions in comparison to open surgical procedures. The aim: The aim of the study was to classify phonatory compensation mechanisms after CO2 laser cordectomy using the HSDI. M aterial and methods: The study included 30 men treated and diagnosed at the Department of Otolaryngology and Department of Clinical Phonoaudiology and Logopedics, Medical University of Bialystok. The control included 30 men with no pathological changes in the larynx. Type III, IV and Va CO2 laser cordectomy have been for glottis cancer treatment. Postoperative evaluation has been conducted 6 months after the surgery. HSDI has been used in larynx visualization. R esults: Type I compensation occurs most frequently in patients after type III cordectomy. Advanced glottis cancer, as an indication for type IV and V cordectomy, leads to epiglottic hyperfunction and phonation involving vestibular folds – type II and III compensation. Type IV compensation is most frequent in type IV cordectomy. C onclusions: The type compensation is connected with the extent of glottis resection. In cordectomy including anterior commissure and the part of opposite fold (type Va), supraglottic hyperfunction with the participation of vestibular folds (type II and III compensation) has been recorded. Transmuscular cordectomy (type III) most often resulted in type I compensation. Type III-Va cordectomy caused reduction or absence of MW, decrease in amplitude and aperiodicity of vibrations in HSDI.
Źródło:
Polish Journal of Otolaryngology; 2020, 74, 2; 31-35
0030-6657
2300-8423
Pojawia się w:
Polish Journal of Otolaryngology
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Medialization thyroplasty in glottis insufficiency due to unilateral vocal fold paralysis and after laser cordectomies – preliminary report
Autorzy:
Rzepakowska, Anna
Osuch-Wójcikiewicz, Ewa
Sielska-Badurek, Ewelina
Niemczyk, Kazimierz
Powiązania:
https://bibliotekanauki.pl/articles/1398469.pdf
Data publikacji:
2017
Wydawca:
Index Copernicus International
Tematy:
thyroplasty
unilateral vocal fold paralysis
cordectomy
glottis insufficiency
voice quality
Opis:
Medialization thyroplasty (type I) is surgical procedure performed on the thyroid cartilage. The major indication for this surgery is significant glottis insufficiency due to unilateral vocal fold paresis. However the proce¬dure is also performed after vocal fold resections during cordectomy. The aim: The evaluation of voice results in patients after medialisation throplasty. Material and methods: In Otolaryngology Department of Medical University of Warsaw there were performed so far 8 thyroplasty procedures under local anaesthesia with implantation of medical silicon protesis. 6 patients had unilat¬eral vocal fold paresis and the rest two underwent in the past laser cordectomy due to T1a vocal carcinoma. Results: There were no complications during and post the surgery. The follow up examination in 1st , 3rd, 6th i 12th months postoperatively revealed for all patients significant improvement of glottal closure in laryngeal videostrobos¬copy. The voice quality improved both in perceptual evaluation (GRBAS scale) and acoustic analysis (F0, jitter, shim¬mer, NHR) in both patients groups. However the rate of improvement was much more significant in group with uni¬lateral vocal fold paresis. In all patients the maximum phonation time (MPT) increased. The self-evaluation of voice quality with Voice Handicap Index questionnaire confirmed also individual improvement. Conclusions: The speech rehabilitations is not successful in each patient with glottis insufficiency. The medialisation thyroplasty remains the standard procedure for permanent improvement of voice quality in those cases.
Źródło:
Polish Journal of Otolaryngology; 2017, 71, 1; 22-29
0030-6657
2300-8423
Pojawia się w:
Polish Journal of Otolaryngology
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
The predictive value of videostroboscopy in the assessment of premalignant lesions and early glottis cancers
Autorzy:
Rzepakowska, Anna
Sielska-Badurek, Ewelina
Osuch-Wójcikiewicz, Ewa
Sobol, Maria
Niemczyk, Kazimierz
Powiązania:
https://bibliotekanauki.pl/articles/1398516.pdf
Data publikacji:
2017
Wydawca:
Index Copernicus International
Tematy:
laryngovideostroboscopy
precancerous lesions
larynx
glottis
early glottic cancer
Opis:
Objective: To assess the sensitivity and specificity of larngovideostroboscopy (LVS) in the diagnosis of precancerous and malignant lesions of the vocal folds. Material and methods: In 175 patients (128 men and 47 women), aged 19-88 years, mean age 61.5, who were admitted to the clinic with diagnosed premalignant conditions of vocal fold mucosa (leukoplakia, chronic hypertrophic inflammatory lesions) and thickening or tumor on the vocal fold, there was performed LVS before the laryngeal microsurgery. The LVS study included: localization of the leasion, movement of the vocal folds, mucosal wave, shape of glottis clousure, amplitude and symmetry of vocal fold vibration. In the evaluation, a point scale was applied for the individual functional parameters. The scale ranged from 0 to 14. Patients with impaired vocal fold motion or absent mucosal wave were positive on LVS for malignant lesions. Those with limitted mucosal wave were positive on LVS for dysplastic lesions. The results were compared with the final histopathological examination and the sensitivity, specificity, accuracy, positive (PPV) and negative (NPV) predictive value were calculated. Results: On the basis of histopathological examination, benign lesions (normal or inflammatory mucosa) accounted for 20% of diagnoses, hypertrophy and parakeratosis for 28%, low and middle grade dysplasia accounted for 10% and malignant lesions (high-grade dysplasia, pre-invasive cancer, Invasive cancer) was diagnosed in 42% of patients. The overall mean score for LVS was 4.5 and 8.0, respectively for benign and malignant lesions. Sensitivity, specificity, accuracy, PPV and NPV of LVS in detecting malignant lesions were respectively - 95.6%, 23.8%, 61.1%, 57.6% and 83.3% and in detecting both premalignant and malignant lesions were respectively – 90.7%, 31.4%, 78.9%, 84.1% and 45.8%. Conclusions: Because of the high sensitivity of LVS in detecting precancerous and malignant lesions, this method is a very good tool for screening of pathology within the larynx.
Źródło:
Polish Journal of Otolaryngology; 2017, 71, 4; 14-18
0030-6657
2300-8423
Pojawia się w:
Polish Journal of Otolaryngology
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Perceptual and acoustic voice analysis in patients with glottis cancer after endoscopic laser cordectomy
Autorzy:
Kosztyła-Hojna, Bożena
Łuczaj, Jarosław
Berger, Greta
Duchnowska, Emilia
Zdrojkowski, Maciej
Łobaczuk-Sitnik, Anna
Biszewska, Jolanta
Powiązania:
https://bibliotekanauki.pl/articles/1397318.pdf
Data publikacji:
2020
Wydawca:
Index Copernicus International
Tematy:
laser cordectomy
glottis cancer
voice quality
voice acoustic analysis
Opis:
Introduction: Treatment of glottis cancer, despite oncological safety, should consider postoperative voice quality. CO2 laser endoscopic cordectomy allows radical removal of the tumor while maintaining respiratory, defensive and phonatory functions. The aim: The aim of the study is perceptual and acoustic evaluation of voice in patients after endoscopic CO2 III–Va laser cordectomy due to glottis cancer. Material and method: The study included 30 men after CO2 cordectomy. 13 (43%) patients underwent type III cordectomy, 6 (20%) – type IV; 11 (37%) – type Va. Voice quality has been assessed 6 months after the surgery. Control group included 30 healthy men of the same age. GRBAS scale has been used in perceptual evaluation of voice. Acoustic analysis has been performed using DiagnoScope Specjalista software. Narrowband spectrography and Maximum Phonation Time (MPT) measure has been performed. Results: In study group, voice has been classified as G1R1B0A0S0 after type III cordectomy; as G1R1B1A1S2 in type IV and as G2R1B1A0S3 in type Va. Acoustic evaluation revealed the highest values of F0, Jitter, Shimmer and NHR after Va cordectomy as well as non-harmonic components in narrowband spectrography and reduction of MPT. Conclusions: Postoperative voice quality depends on the type of cordectomy. Perceptual assessment indicates that type IV and Va cordectomy cause intensification of voice disorders. Parameters of acoustic evaluation increase with the extent of the procedure. The presence of non-harmonic components in narrowband spectrography increases with the extent of cordectomy, such as the reduction of MPT. Preservation of anterior commissure influences good voice quality in perceptual and acoustic assessment.
Źródło:
Polish Journal of Otolaryngology; 2020, 74, 3; 23-28
0030-6657
2300-8423
Pojawia się w:
Polish Journal of Otolaryngology
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-4 z 4

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies