Tytuł:
Evaluation of error in the performance of power corrected ophthalmic lenses
Autorzy:
Trujillo-Schiaffino, G
Salas-Peimbert, D P
Anguiano-Morales, M
Malacara-Doblado, D
Vega-Pineda, J
Powiązania:
https://bibliotekanauki.pl/articles/173334.pdf
Data publikacji:
2013
Wydawca:
Politechnika Wrocławska. Oficyna Wydawnicza Politechniki Wrocławskiej
Tematy:
ophthalmic lenses
refractive correction error
Hartmann test
Opis:
In this work, we describe a new method for assessing the refractive correction error in power corrected ophthalmic lenses. The ideal power distribution map corresponding to the lens design to be measured is initially obtained. Then, using some known techniques, the real power distribution map of the lens under test is obtained. Finally, the difference between the two distributions is computed, obtaining a distribution map of the refractive correction error of the lens under analysis. In the paper, we describe the implementation of the proposed method using the Hartmann test to analyze a corrected power ophthalmic lens. The technique is analyzed, and its effects on measurement resolution discussed. This method can be useful to verify the designing errors in the lab or to verify manufacturing errors of ophthalmic lenses during mass production.
Źródło:
Optica Applicata; 2013, 43, 2; s. 261-270
0078-5466
1899-7015
Pojawia się w:
Optica Applicata
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Engineering the optical and mechanical properties exhibited by a titanium dioxide thin film with gold nanoparticles
Autorzy:
Morales-Bonilla, S
Torres-Torres, C
Trejo-Valdez, M
Torres-Torres, D
Urriolagoitia-Sosa, G
Hernandez-Gomez, L H
Urriolagoitia-Calderon, G
Powiązania:
https://bibliotekanauki.pl/articles/174855.pdf
Data publikacji:
2013
Wydawca:
Politechnika Wrocławska. Oficyna Wydawnicza Politechniki Wrocławskiej
Tematy:
optical Kerr effect
nonlinear optics
nanomaterials
Opis:
Thermo-optic and electrostrictive contributions to the nonlinear refractive index were observed in a titanium dioxide thin film with embedded gold nanoparticles. A sol–gel method was employed for preparing thin solid film samples. The nanosecond nonlinear optical properties and the Young’s modulus parameter were changed by shifting the optical absorption band associated with the localized surface plasmon of resonance of the gold nanoparticles with platinum. The third order nonlinear optical phenomena exhibited by the sample were induced by the second harmonic of a Nd-YAG laser with 532 nm wavelength; the nonlinear optical measurements were obtained by monitoring the transmittance and the amplitude modification for the vectorial components of the electric fields in a two-wave interaction. Optical evaluations were confirmed considering a straightforward measurement of the change in the refractive index of the sample when the sample was located in a Michelson interferometer.
Źródło:
Optica Applicata; 2013, 43, 4; 651-661
0078-5466
1899-7015
Pojawia się w:
Optica Applicata
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
An exact approach for radius of curvature measurement in a calibration test sphere
Autorzy:
Jalife-Chavira, Jaime M.
Trujillo-Schiaffino, Gerardo
Mendoza-Villegas, Paloma G.
Salas-Peimbert, Didia P.
Anguiano-Morales, Marcelino
Corral-Martínez, Luis F.
Zendejas-Hernández, Edgar
Powiązania:
https://bibliotekanauki.pl/articles/2086760.pdf
Data publikacji:
2022
Wydawca:
Politechnika Wrocławska. Oficyna Wydawnicza Politechniki Wrocławskiej
Tematy:
keratometry
radius of curvature
diopter
cosine fringe pattern
film
Opis:
In this paper we present a technique to measure the radius of curvature of a test sphere based on the relation between acquired images of a circular cosine fringe pattern and size of virtual image formed on the calibration test surface. Radius of curvature is calculated with the exact equation proposed, using the parameters of the optical setup. Fringe pattern evaluation was performed by locating extrema indices. The mathematical formulation as well as the experimental setup and results are presented. After applying a linear fit algorithm to the data as a method of compensation, obtained results show an error within the tolerance established by the ISO 10343 specifications.
Źródło:
Optica Applicata; 2022, 52, 2; 229--242
0078-5466
1899-7015
Pojawia się w:
Optica Applicata
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-3 z 3

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies