Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "uzdatnianie" wg kryterium: Temat


Tytuł:
Zastosowanie procesów pogłębionego utleniania do uzdatniania wody
Application of advanced oxidation processes to water treatment
Autorzy:
Biń, A.
Powiązania:
https://bibliotekanauki.pl/articles/237087.pdf
Data publikacji:
1998
Wydawca:
Polskie Zrzeszenie Inżynierów i Techników Sanitarnych
Tematy:
utlenianie pogłębione
uzdatnianie wody
Opis:
The paper provides an account of uses where advanced oxidation processes(AOP)are applicable,particular consideration being given to the removal of hazardous pollutants from water taken in for municipal supply.Examples of AOP development are given as well.The general principle of the AOPis to form highly reactive free radical (specifically hydroxyl radicals) in the aqueous medium.To produce these species use is made of ozone,hydrogen peroxide,UV radaition,catalysts (TiO2,MnO2,Fe2+)-single of in combinations-if beneficial synergetic effects are abserved.The mechanisms governing the AOP process,as well as a variety of engineering applications, are discussed in detail.The AOP is particularly useful in removing non-biodegradable water pollutants which are resistant to conventional treatment.
Źródło:
Ochrona Środowiska; 1998, 1; 4-6
1230-6169
Pojawia się w:
Ochrona Środowiska
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Parametry regeneracji węgli aktywnych stosowanych do uzdatniania wody w ZPW "Dziećkowice"
Regeneration parameters of the activated carbons made use of in the Dziećkowice Waterworks
Autorzy:
Dębowski, Z.
Nowak, B.
Powiązania:
https://bibliotekanauki.pl/articles/237173.pdf
Data publikacji:
1999
Wydawca:
Polskie Zrzeszenie Inżynierów i Techników Sanitarnych
Tematy:
węgle aktywne
uzdatnianie wody
ZPW "Dziećkowice"
Źródło:
Ochrona Środowiska; 1999, 4; 37-40
1230-6169
Pojawia się w:
Ochrona Środowiska
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Wykorzystanie komputerowej symulacji procesów przepływowych (CFD) w projektowaniu urządzeń do uzdatniania wody
Numerical simulation of fluid flow (CFD Method) as a useful tool in the design of water treatment devices
Autorzy:
Rudniak, L.
Możaryn, W.
Powiązania:
https://bibliotekanauki.pl/articles/237714.pdf
Data publikacji:
2001
Wydawca:
Polskie Zrzeszenie Inżynierów i Techników Sanitarnych
Tematy:
uzdatnianie wody
procesy przepływowe
symulacja komputerowa
Opis:
Numerical simulation of fluid flow can be widely used in water treatment processes. The uses where numerical simulation of fluid flow (CFD method) is applicable are reviewed. CFD software provides the users with information about fluid flow (velocity profile, pressure profile), heat transfer (temperature profile) and mass transfer (pollutants, chemical reactions, concentration profiles) in real water treatment systems by numerical solution of the momentum, energy and mass equations. The CFD method is very useful in the analysis of fluid flow machineries, in troubleshooting and parametric studies.
Źródło:
Ochrona Środowiska; 2001, 3; 29-31
1230-6169
Pojawia się w:
Ochrona Środowiska
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Zastosowanie koagulacji powierzniowej do uzdatniania wód infiltracyjnych
Infiltration water treatment by direct filtration
Autorzy:
Dziubek, A.
Maćkiewicz, J.
Powiązania:
https://bibliotekanauki.pl/articles/236985.pdf
Data publikacji:
1999
Wydawca:
Polskie Zrzeszenie Inżynierów i Techników Sanitarnych
Tematy:
koagulacja powierzchniowa
uzdatnianie wód infiltracyjnych
jakość wody
Źródło:
Ochrona Środowiska; 1999, 3; 57-60
1230-6169
Pojawia się w:
Ochrona Środowiska
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Wybrane problemy w oczyszczaniu wody do picia i na potrzeby gospodarcze
Some major problems faced in water treatment for drinking purposes
Autorzy:
Świderska-Bróż, M.
Powiązania:
https://bibliotekanauki.pl/articles/237015.pdf
Data publikacji:
1999
Wydawca:
Polskie Zrzeszenie Inżynierów i Techników Sanitarnych
Tematy:
jakość wód
zanieczyszczenie wód
ochrona środowiska
uzdatnianie wody
Opis:
The main problems of drinking water treatment and selected micropollutants removal are presented. The paper gives an account of tie available methods and new technological trends securing the drinking water standards. It should be noted,however, that the application of efficient and safe water treatment methods, enabling elimination of polluting species which are difficult to remove, are often concomitant with troublesome modifications of the treatment trains, thus raising the overall treatment cost.
Źródło:
Ochrona Środowiska; 1999, 3; 7-12
1230-6169
Pojawia się w:
Ochrona Środowiska
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Analiza wpływu jakości wody na dawkę dwutlenku chloru
Influence of water quality on chlorine dioxide dose
Autorzy:
Wąsowski, J.
Powiązania:
https://bibliotekanauki.pl/articles/237534.pdf
Data publikacji:
2001
Wydawca:
Polskie Zrzeszenie Inżynierów i Techników Sanitarnych
Tematy:
uzdatnianie wody
jakość wody
dwutlenek chloru
analiza matematyczna
Opis:
The aim of the study was to investigate the effect of raw water quality on the values of the chlorine dioxide doses which are to be used for preoxidation and final disinfection. Using the multiple regression method, the relations between the water quality parameters of choice (temperature, colour, COD, TOC, UV-absorbance and plankton content) and the chlorine dioxide dose were established. Data for mathematical analysis were collected during investigations into the treatment process carried out in the waterworks of Warsaw. Mathematical analysis of the results revealed a strong correlation of the chlorine dioxide dose with UV-absorbance, colour, TOC and COD.
Źródło:
Ochrona Środowiska; 2001, 4; 33-35
1230-6169
Pojawia się w:
Ochrona Środowiska
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Badania technologiczne nad doborem złoża filtracyjnego do uzdatniania wód powierzchniowych
Technological investigations into the choice of filter bed for effective surface water treatment
Autorzy:
Balcerzak, W.
Zymon, W.
Powiązania:
https://bibliotekanauki.pl/articles/237710.pdf
Data publikacji:
2001
Wydawca:
Polskie Zrzeszenie Inżynierów i Techników Sanitarnych
Tematy:
wody powierzchniowe
uzdatnianie wody
złoża filtracyjne
badania technologiczne
Opis:
Pilot-plant technological investigations were carried out with the aim to retrofit the existing treatment train for surface water. The treatment train under study involved continuous coagulation, sedimentation and filtration on single-layer sand beds or double-layer anthracite-sand beds of varying grain size distribution, particular consideration being given to the problem of how to obtain high-quality water after filtration. The investigations covered a time span which allowed the seasonal pattern of water quality variations to be examined. Turbidity (kept below 0.45 NTU) was adopted as the parameter that best characterized the quality of treated water. For the anticipated turbidity value which could not be exceeded an average duration of the filter cycle was established.
Źródło:
Ochrona Środowiska; 2001, 3; 25-27
1230-6169
Pojawia się w:
Ochrona Środowiska
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Problem bromianów- współczesny stan badań oraz modyfikacje technologii uzdatniania wody do picia
Bromate problem-current state of research and advances in water treatment technologies
Autorzy:
Biń, A.
Możaryn, W.
Powiązania:
https://bibliotekanauki.pl/articles/236987.pdf
Data publikacji:
1999
Wydawca:
Polskie Zrzeszenie Inżynierów i Techników Sanitarnych
Tematy:
bromiany
technologia uzdatniania wody
woda do picia
uzdatnianie wody
Opis:
The paper provides a critical review of recent publications on how bromates form and how the available water treatment methods can minimize their concentrations. From this review it cast be concluded that the molecular and radical mechanisms governing tJie reactions of bromine compounds with ozone in the aquatic environment are quite well understood. They all evidence the complex character, as wellas the potential influence of the process parameters involved on the extent of these reactions and the conversion of bromides into bromates. This finding holds particularly for the water matrix which is treated with ozone or for the advanced oxidation processes which are in use now. Many investigators concentrated upon the problem of how to abate the bromate levels accounted for by the complex reactions of bromine compounds with oxidants (ozone, hydrogen peroxide, catalysts) as well as UV irradiation, and how to provide efficient removal of those pollutants from the treated water. In this context, the papers by the Dutch researchers [12-15] and the study by Von Gunten et al. [6] deserve particular attention, They show that it is possible to optimize the treatment process so as to meet the disinfection requirement, to remove the micropollutants (mainly pesticides) from the water, and to keep th& concentration of bromine within the allowable range. The authors mentioned emphasize not only the potentiality for achieving good treatment effects when using hydrogen peroxide, but also some advantages resulting from the application of UV irradiation and catalytic processes [TiO2, synergetic effects of Fe ani Mn removal).
Źródło:
Ochrona Środowiska; 1999, 3; 49-56
1230-6169
Pojawia się w:
Ochrona Środowiska
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Niekonwencjonalne metody uzdatniania wód podziemnych
Non -coventional methods of groundwater treatment
Autorzy:
Maćkiewicz, J.
Powiązania:
https://bibliotekanauki.pl/articles/237269.pdf
Data publikacji:
1998
Wydawca:
Polskie Zrzeszenie Inżynierów i Techników Sanitarnych
Tematy:
wody podziemne
uzdatnianie wód podziemnych
koagulacja
złoże piroluzytowe
związki azotowe
dekarbonizacja
Opis:
Poland's groundwater resources vary widely in quality,which calls for adeguate treatment methods. The paper gives a characterization of those waters and suggests some non-conventional methods of treating them.Thus,lime decarbonization was found to yeld quite good treatment effects.Treatment efficiency can be noticeably increased when coagulation is run direct in the filter bed.The use of a pyrolusite bed is recommendable not only because of iron and manganese removal.It provides additionally a decrease of ammonia nitrogen concentration. The paper also describes biological methods for the removal of nitrogen compounds,and provides data on relevant treatment train.
Źródło:
Ochrona Środowiska; 1998, 3; 31-34
1230-6169
Pojawia się w:
Ochrona Środowiska
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Powstawanie ubocznych produktów chlorowania wody zawierającej uracyl i jego pochodne
Formation of by-products during chlorination of uracil containing water
Autorzy:
Kucharski, M.
Powiązania:
https://bibliotekanauki.pl/articles/237486.pdf
Data publikacji:
2001
Wydawca:
Polskie Zrzeszenie Inżynierów i Techników Sanitarnych
Tematy:
uzdatnianie wody
chlorowanie wody
produkty uboczne
uracyl
pochodne uracylu
właściwości toksyczne
Opis:
Investigated were the reactions that occur in the water between the free available chlorine (FAC) and uracil over the FAC/uracil ratio varying from 0.25 to 10 mol/mol and pH ranging from 6 to 9. The course of the reaction was related to the pH of the water, as well as to the presence of bromide, iodide and fluoride ions. It was found that when the FAC/uracil ratio was low, 5-chlorouracil was the only chlorination product. At FAC/uracil ratios greater than 10, dichlorouracil and nitrogen trichloride were present in the chlorination products, whereas chlorouracil was absent. In the presence of iodides and bromides in the investigated water, chlorination also accounted for the formation of 5-iodouracil and 5-bromouracil.
Źródło:
Ochrona Środowiska; 2001, 4; 23-25
1230-6169
Pojawia się w:
Ochrona Środowiska
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Badania wpływu wstępnego uzdatniania wody z zastosowaniem flotacji ciśnieniowej na dawkę ozonu
Effect of DAF-aided water pretreatment on the ozone dose
Autorzy:
Sroka, M.
Powiązania:
https://bibliotekanauki.pl/articles/236390.pdf
Data publikacji:
2004
Wydawca:
Polskie Zrzeszenie Inżynierów i Techników Sanitarnych
Tematy:
ozonowanie
flotacja ciśnieniowa
uzdatnianie wody
ozonation
dissolved air flotation (DAF)
water treatment
Opis:
Omówiono wyniki badań nad wpływem wstępnego uzdatniania wody z zastosowaniem flotacji ciśnieniowej (DAF) na dawkę ozonu w procesie ozonowania wstępnego. Badania przeprowadzono na stacji pilotowej Zakładu Wodociągu Północnego w Wieliszewie, który ujmuje wodę z Zalewu Zegrzyńskiego. Z przeprowadzonych badań wynika, że zastosowanie wstępnego uzdatniania wody z zastosowaniem flotacji ciśnieniowej po pierwszym stopniu koagulacji pozwoliło na 4-krotne zmniejszenie dawki ozonu wyrażonej w gO3/m3 lub prawie 2-krotne zmniejszenie dawki ozonu odniesionej do zawartości ogólnego węgla organicznego w wodzie, wyrażonej w gO3/gC. Zastosowana metoda uzdatniania wody pozwala na istotne zmniejszenie dawki ozonu, a zatem przyczyni się do ograniczenia ilości powstających ubocznych produktów utleniania zanieczyszczeń organicznych obecnych w ujmowanej wodzie, jak również pozwoli na obniżenie kosztów uzdatniania wody.
The objective of the experimental study was to find out how the pretreatment of the water involving dissolved air flotation (DAF) influences the ozone dose to be used in the preozonation process. The experiments were carried out at the pilot plant of the Warsaw Waterworks (Wodociąg Północny, Wieliszew), which draws water from the Zegrzyński impoundment lake. The results are promising. The DAF-aided pretreatment of the water after the first stage of coagulation enabled a 4fold reduction of the ozone dose expressed in gO3/m3 or an almost 2fold reduction related to the TOC content in the water and expressed in gO3/gC. With the proposed water treatment method, the ozone dose can be reduced noticeably, thus limiting the generation of by-products during oxidation of the organic pollutants that are present in the lake water. Another major benefit is the potentiality for reducing the overall water treatment cost.
Źródło:
Ochrona Środowiska; 2004, R. 26, nr 3, 3; 21-24
1230-6169
Pojawia się w:
Ochrona Środowiska
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Ocena biologicznej aktywności filtrów węglowych w uzdatnianiu wód powierzchniowych na przykładzie wodociągu "Sulejów-Łódź"
Evaluating the Biological Activity of Carbon Filters in Surface Water Treatment: A Case Study
Autorzy:
Wolborska, A.
Zarzycki, R.
Cyran, J.
Grabowska, H.
Wybór, M.
Powiązania:
https://bibliotekanauki.pl/articles/236620.pdf
Data publikacji:
2003
Wydawca:
Polskie Zrzeszenie Inżynierów i Techników Sanitarnych
Tematy:
węgiel aktywny
uzdatnianie wody
sorpcja
biosorpcja
activated carbons
water treatment
sorption
biosorption
Opis:
W pracy przedstawiono wyniki 10-miesięcznych badań pilotowych na złożu granulowanego węgla aktywnego TL 830, prowadzonych w stacji uzdatniania wody w Kalinku (Wodociąg "Sulejów-Łódź"). Równolegle z badaniami jakości wody (utlenialność, absorbancja w UV, rozpuszczony węgiel organiczny, ubytku tlenu rozpuszczonego w wodzie) przeprowadzono kontrolę stopnia wyczerpania węgla przez oznaczenie liczby jodowej. Określono kryteria biologicznego wpracowania węgla aktywnego oraz wyznaczono zapotrzebowanie wody na dwutlenek chloru. Aktywność biomasy oceniono przy pomocy testu EMS, zaś zmiany chłonności węgla aktywnego-liczbą jodową. Filtracja wody przez aktywnie biologicznie złoże węglowe okazała się skuteczną metodą usuwania zanieczyszczeń organicznych, dzięki czemu uzyskano wymaganą jakość wody uzdatnionej oraz 2¸3-krotne zmniejszenie zapotrzebowania wody na dwutlenek chloru, a także ograniczenie powstawania ubocznych produktów dezynfekcji. Jednocześnie stwierdzono efekt bioregeneracji złoża węgla aktywnego.
A 10-month pilot-plant-scale experimental study of TL 830 type granular activated carbon (GAC) was carried out at the water treatment station of the Waterworks of Kalinko (Sulejów-Łódź Water Supply System). The study included analyses of water quality parameters (COD, UV absorbance, dissolved organic carbon, oxygen loss), estimation of GAC exhaustion (by the iodine number method), continuous measurements of the hydraulic parameters of the GAC bed, physicochemical, hydrobiological and bacteriological analyses, as well as the determination of the chlorine dioxide demand for the inflowing and outflowing water. The objective of the study was to determine and compare the biological activity of the TL 820 GAC filter bed and its performance in the biosorption process. The activity of the biomass and the absorbing of the GAC were estimated by the EMS test and ion number, respectively. Water filtration through the biosorption bed was found to be an efficient method of organic matter removal, yielding water of the desired quality. The demand for chlorine dioxide decreased two- and three-fold, the formation of unwanted side products was reduced, and a bioregeneration of the GAC bed was observed.
Źródło:
Ochrona Środowiska; 2003, R. 25, nr 4, 4; 27-32
1230-6169
Pojawia się w:
Ochrona Środowiska
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Wpływ wybranych parametrów pracy filtrów węglowych na jakość wody z Wodociągu Praskiego w Warszawie
Effect of some GAC filter parameters on water quality: a case study
Autorzy:
Mossakowska, A.
Powiązania:
https://bibliotekanauki.pl/articles/237502.pdf
Data publikacji:
2001
Wydawca:
Polskie Zrzeszenie Inżynierów i Techników Sanitarnych
Tematy:
Wodociąg Praski
uzdatnianie wody
jakość wody
badania technologiczne
filtracja wody
filtry węglowe
Opis:
The results of technological investigations into the Praski Water Treatment Plant were presented. The decision was made to include ozonation or indirect oxidation, as well as filtration on GAC bed, into the existing treatment train. The fundamental criterion for the systems understudy was that the disinfecting chlorine dioxide dose must not exceed 0.4 g/m[3]. For the purpose of engineering design, the treatment train was extended by the inclusion of indirect ozonation and GAC filtration with a contact time of 34 minutes. The investigations showed that, considering the requirement of limiting the ozone dose, the prerequisite to achieve the treatment effects desired is to extend the time of water-GAC contact to at least 30 minutes. The GAC to be used should display a high sorbing capacity, and the GAC bed should provide favourable conditions for the occurrence of biological processes.
Źródło:
Ochrona Środowiska; 2001, 3; 41-44
1230-6169
Pojawia się w:
Ochrona Środowiska
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Zastosowanie czystego tlenu do uzdatniania wód podziemnych
On the application of pure oxugen to groundwater-treatment
Autorzy:
Sobczyk, M.
Powiązania:
https://bibliotekanauki.pl/articles/237538.pdf
Data publikacji:
2001
Wydawca:
Polskie Zrzeszenie Inżynierów i Techników Sanitarnych
Tematy:
wody podziemne
uzdatnianie wód
związki żelaza
związki manganu
napowietrzanie
tlen czysty techniczny
Opis:
The objective of the study was to examine the efficiency of iron and manganese removal for groundwater with the use of various oxidants. Pilot-scale experiments were run direct at the water intake. The oxidizing agents of choice were atmospheric oxygen and pure oxygen. Consideration was given to the problem of how the method of oxidation affected iron and manganese content and head loss variations. Of the two oxidants tested, pure oxygen was found to yield higher efficiencies of iron and manganese removal. The use of pure oxygen as an oxidizing agent should therefore be recommended.
Źródło:
Ochrona Środowiska; 2001, 4; 37-39
1230-6169
Pojawia się w:
Ochrona Środowiska
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Wpływ temperatury na skuteczność uzdatniania wód górskich w procesie koagulacji
Influence of temperature on the effetiveness of mountain water treatment by coagulation
Autorzy:
Gumińska, J.
Powiązania:
https://bibliotekanauki.pl/articles/237570.pdf
Data publikacji:
2002
Wydawca:
Polskie Zrzeszenie Inżynierów i Techników Sanitarnych
Tematy:
wody górskie
zanieczyszczenia wód
związki organiczne
uzdatnianie wód górskich
koagulacja
temperatura wody
Opis:
Natural waters in mountain areas are characterized by a high coloured matter content and turbidity, especially during heavy rains and snow melting. A conventional treatment train for mountain water, which consists of filtration and disinfection, is insufficient to provide drinking water of appropriate quality. To eliminate this drawback it is necessary to include coagulation as a unit process. The present paper describes a pilot-scale study into the influence of temperature on the efficiency of conventional treatment. The paper also shows an attempt to explain the difficulties encountered when carrying out volume coagulation at decreased temperatures. Winter temperatures have an adverse effect on the coagulation process. Although they do not inhibit the hydrolysis of the alum coagulant, and even though the alum hydroxide floes are able to remove organic substances from water - the flocs themselves have a short life and dissolve.
Źródło:
Ochrona Środowiska; 2002, 1; 27-32
1230-6169
Pojawia się w:
Ochrona Środowiska
Dostawca treści:
Biblioteka Nauki
Artykuł

Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies