Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "Luminescence" wg kryterium: Temat


Wyświetlanie 1-3 z 3
Tytuł:
Detection of radiation treatment of dry plant extracts by thermoluminescence and pulsed photostimulated luminescence. Comparative study
Autorzy:
Lehner, K.
Malec-Czechowska, K.
Stachowicz, W.
Guzik, G.
Powiązania:
https://bibliotekanauki.pl/articles/148034.pdf
Data publikacji:
2009
Wydawca:
Instytut Chemii i Techniki Jądrowej
Tematy:
plant extract
detection
irradiation
thermoluminescence
photostimulated luminescence
Opis:
Results of the examination of the variety of dry plant extracts (Thyme extract, Celery seed extract, Artichoke extract, Citrus aurantium extract and others) by two different detection methods are described. Both PSL and TL methods are presented and discussed. Comparative study based on the analysis of the results obtained by thermoluminescence (TL) and photostimulated luminescence (PSL) measurements delivered the arguments that preselection of detection methods based on model studies is rational to be adapted in analytical laboratories specialized in the detection of irradiated foods.
Źródło:
Nukleonika; 2009, 54, 2; 99-105
0029-5922
1508-5791
Pojawia się w:
Nukleonika
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Development of crystals based on cesium iodide for measurements of gamma radiation and alpha particles
Autorzy:
Pereira, M. C. C.
Filho, T. M.
Hamada, M. M.
Powiązania:
https://bibliotekanauki.pl/articles/148098.pdf
Data publikacji:
2009
Wydawca:
Instytut Chemii i Techniki Jądrowej
Tematy:
scintillator
crystals
gamma radiation
alpha particles
luminescence
Opis:
During the past 50 years, scintillators have been among the most important nuclear radiation detectors. Inorganic scintillators are widely used in experimental nuclear physics, high energy physics, nuclear medicine, nuclear tomography, environmental studies and many other fields of use. Scintillation crystals based on cesium iodide (CsI) are matters of relatively low hygroscopy, high atomic number, easy handling and low cost, characteristics that favor their use as radiation detectors. In this work, the growth of pure CsI crystals, CsI:Br and CsI:Pb, using the Bridgman technique, is described. Ions of divalent lead (Pb2+) doped in the crystal structures are efficient emission centers and their application as scintillators is still the reason for intensive studies. Recently, promising results have been found for crystals of CsI doped by bromine (Br) for their use as radiation detectors. The concentration of the bromine doping element (Br) was studied in the range from 1.5 × 10–1 M to 10–2 M and the lead (Pb) in the range from 10–2 M to 5 × 10–4 M. To evaluate the scintillators developed, systematic measurements were carried out for luminescence emission and luminescence decay time for gamma radiation, Vickers microhardness assays, and analysis of crystals response to the gamma radiation, in the energy range from 350 keV to 1330 keV, and alpha particles from a 241Am source, with energy of 5.54 MeV. The obtained values for luminescence decay time for CsI:Br and CsI:Pb crystals, were from 13 to 19 ns.
Źródło:
Nukleonika; 2009, 54, 3; 151-155
0029-5922
1508-5791
Pojawia się w:
Nukleonika
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Reliability of light-stimulated photoluminescence (PSL) in detection of irradiated food comparison with thermoluminescence method (TL)
Autorzy:
Guzik, G. P.
Stachowicz, W.
Powiązania:
https://bibliotekanauki.pl/articles/147688.pdf
Data publikacji:
2008
Wydawca:
Instytut Chemii i Techniki Jądrowej
Tematy:
irradiation
detection
food products
spices
herbs
blends
photostimulated luminescence (PPSL)
thermoluminescence (TL)
Opis:
The detection of irradiation of several classes of food products with the use of thermoluminescence (TL) and photostimulated luminescence (PPSL) has been proceeded. The comparison of the results obtained by both methods has been done and reliability of the PPSL method as compared with the TL method evaluated. Conclusion concerning the usefulness of such evaluation to the practice has been drawn.
Źródło:
Nukleonika; 2008, 53, suppl. 1; 25-29
0029-5922
1508-5791
Pojawia się w:
Nukleonika
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-3 z 3

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies