Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "Karpińska, K." wg kryterium: Autor


Wyświetlanie 1-4 z 4
Tytuł:
Investigation of the influence of high humidity and exposure duration on the measurement results of radon concentration by means of PicoRad system in the CLOR calibration chamber
Autorzy:
Stawarz, O.
Karpińska, O.
Mamont-Ciesla, K.
Powiązania:
https://bibliotekanauki.pl/articles/148604.pdf
Data publikacji:
2006
Wydawca:
Instytut Chemii i Techniki Jądrowej
Tematy:
radon
activated charcoal
relative humidity
duration of exposure
PicoRad system
Opis:
PicoRad system based on activated charcoal collectors and liquid scintillation counter is one of the most popular passive methods of radon measurements which may be used both indoors and in other environments such as caves, tunnels, mines etc. It is well known that charcoal is also a very good adsorber of water vapor and it can reduce adsorption efficiency for radon. In PicoRad collectors, the charcoal is mixed with a dessicant to lower this effect. A series of expositions of PicoRad detectors was performed in a Central Laboratory for Radiological Protection (CLOR) radon calibration/climatic chamber to study the effect of high relative humidity on the airborne radon concentration measurements and the dependence of the results on the duration of exposure. The results obtained from the PicoRad system were referred to the mean concentrations delivered by an AlphaGUARD monitor, Genitron (GmbH), Germany. The main conclusions are the following: 1) the PicoRad system results are not affected by high relative humidity, including extreme values of 90-96%, for the duration of exposure up to ca. 24 h; 2) in the relative humidity range of 75-96% the correction coefficient linearly depends on the duration of exposure reaching a value of ca. 16 for 96 h exposure; 3) the PicoRad system delivers results corresponding better to the mean value of radon concentration in the last 6 h interval of exposure than that in the whole exposure duration. This finding is particularly important for the calibration of PicoRad collectors in the conditions of decreasing radon concentration due to radon decay.
Źródło:
Nukleonika; 2006, 51,suppl.2; 53-57
0029-5922
1508-5791
Pojawia się w:
Nukleonika
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Seasonal changeability of indoor radon concentrations in one-family house
Autorzy:
Karpińska, M.
Mnich, Z.
Kapała, J.
Antonowicz, K.
Powiązania:
https://bibliotekanauki.pl/articles/147979.pdf
Data publikacji:
2004
Wydawca:
Instytut Chemii i Techniki Jądrowej
Tematy:
radon
seasonal changes
Opis:
Indoor radon concentration undergoes 24-hour and seasonal changes. The paper presents first in Poland results of radon concentration changeability in one building during the whole year. We performed 103 measurements of indoor radon concentrations. The following parameters of radon concentration distribution were obtained: arithmetic mean - 224.1 Bq m 3, geometric mean - 194.5 Bq m 3, median - 207 Bq m 3, and geometric standard deviation - 1.84. The minimum observed value was 22 Bq m 3 and the maximum - 748 Bq m 3. We determined the monthly and annual values of radon concentrations. The values for particular months are in the range of 0.5 to 1.6 of the annual mean. We observed a correlation between the mean radon concentrations in the examined buildings and the differences in the mean values of indoor (R = 0.91, p < 0.05) and outdoor temperatures (R = 0.91, p < 0.05). There was also a connection between the radon concentration inside the buildings and the changes in atmospheric pressure.
Źródło:
Nukleonika; 2004, 49, 1; 33-36
0029-5922
1508-5791
Pojawia się w:
Nukleonika
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Comparison of radon hazard to inhabitants of the Augustów Plane sandr and inhabitants of the Suwałki region of fluvioglacial sands and gravels
Autorzy:
Karpińska, M.
Wołkowicz, S.
Mamont-Cieśla, K.
Mnich, Z.
Kapała, J.
Powiązania:
https://bibliotekanauki.pl/articles/148346.pdf
Data publikacji:
2003
Wydawca:
Instytut Chemii i Techniki Jądrowej
Tematy:
building
geology
radon
Opis:
In a region of two lithologic units: the Augustów Plane sandr and the Suwałki sands and fluvioglacial gravels, 134 measurements of radon concentrations in dwelling houses were performed. An integral method of solid state nuclear trace detectors (SSNTD) was used in the studies. Statistically significant differences in the radon concentrations in both geological units were obtained. The radon concentration arithmetic mean was 197 Bq m-3, geometric mean - 119 Bq m-3, median - 111 Bq m-3, the maximal value being 1225 Bq m-3 in the region of the Suwałki fluvioglacial sands and gravels. The Augustów Plane sandr revealed arithmetic mean of radon concentration equal to 123 Bq m-3, geometric mean – 80 Bq m-3, and median equal to 67 Bq m-3, maximal value 695 Bq m-3. The annual effective dose of the radon obtained by inhabitants of the Augustów Plane sandr is 1.7 mSv and for inhabitants of the Suwałki fluvioglacial sands and gravels it is 2.5 mSv.
Źródło:
Nukleonika; 2003, 48, 4; 197-200
0029-5922
1508-5791
Pojawia się w:
Nukleonika
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Intercomparison of radon CR-39 detector systems conducted in CLORs calibration chamber
Autorzy:
Mamont-Cieśla, K.
Stawarz, O.
Karpińska, M.
Kapała, J.
Kozak, K.
Grządziel, D.
Chałupnik, S.
Chmielewska, I.
Olszewski, J.
Przylibski, T. A.
Żebrowski, A.
Powiązania:
https://bibliotekanauki.pl/articles/148842.pdf
Data publikacji:
2010
Wydawca:
Instytut Chemii i Techniki Jądrowej
Tematy:
radon-222
CR-39 track detector
intercomparison
RadoSys
Opis:
Six radon laboratories, which perform indoor radon measurements to jointly investigate temporal variations of radon concentration in houses in a couple of regions in Poland, participated in the intercomparison exercise. There are involved three commercially available Hungarian RadoSys systems and four own laboratory methods. All of them are based on the etched-track CR-39 detectors. The intercomparison was conducted in a calibration laboratory of the Central Laboratory for Radiological Protection (CLOR), Warsaw, Poland, accredited by the Polish Center for Accreditation (previously AP 101, at present AP 057). Comparison measurements were performed during three expositions in the CLOR’s radon calibration chamber under controlled normal climatic conditions and steady radon concentration. The results were referred to the value of the radon concentration determined by AlphaGUARD monitor traceable to the primary 222Rn standard in Physikalisch-Technische Bundesanstalt (PTB), Braunchweig, Germany. The mean performance ratio defined as a ratio of the reference to participant’s result range from 0.88 to 1.31.
Źródło:
Nukleonika; 2010, 55, 4; 589-593
0029-5922
1508-5791
Pojawia się w:
Nukleonika
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-4 z 4

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies