Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "Hashemi, M." wg kryterium: Autor


Wyświetlanie 1-2 z 2
Tytuł:
A novel control-rod drive mechanism via electromagnetic levitation in MNSR
Autorzy:
Divandari, M.
Hashemi-Tilehnoee, M.
Khaleghi, M.
Hosseinkhah, M.
Powiązania:
https://bibliotekanauki.pl/articles/147631.pdf
Data publikacji:
2014
Wydawca:
Instytut Chemii i Techniki Jądrowej
Tematy:
magnetic levitation system
nuclear reactor
state feedback
tracking
Opis:
In this paper, an electromagnetic levitation system was used with a synchronous motor to navigate the control rod of a small-type research reactor. The result from this prototype magnetic levitation system was in agreement with simulation results. The control system was programmed in MATLAB through open-loop system, closed-loop with state feedback and closed-loop with state feedback integral tracking. The final control system showed the highest performance with a low positioning error. Our results showed that the developed control system has the potential to be used as a reliable actuator in nuclear reactors to satisfy higher performance and safety.
Źródło:
Nukleonika; 2014, 59, 2; 73-79
0029-5922
1508-5791
Pojawia się w:
Nukleonika
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
The effect of external wedge on the photoneutron dose equivalent at a high energy medical linac
Autorzy:
Hashemi, , S. M.
Raisali, G.
Taheri, M.
Majdabadi, A.
Ghafoori, M.
Powiązania:
https://bibliotekanauki.pl/articles/147071.pdf
Data publikacji:
2011
Wydawca:
Instytut Chemii i Techniki Jądrowej
Tematy:
photoneutron
linac
polycarbonate (PC)
external wedge
radiotherapy
Opis:
Medical linacs used in radiotherapy produce bremsstrahlung spectra. In the energy range from 8 to 25 MV medical linacs produce, besides the clinically useful electron and photon beams, secondary neutrons. The aim of this study was to investigate the effect of an external wedge filter on the photoneutron dose equivalent produced by a medical linac at patient plane. Polycarbonate (PC) films were used for the determination of photoneutron dose equivalent produced by a Varian 2100 C/D linac working at 18 MV photon mode. Neutron dose equivalent was measured at distances 0, 10, 20 and 50 cm from the center of the X-ray beam for open field and after inserting a wedge filter. It was noted that by inserting the external wedge in the path of the X-ray beam, the photoneutron dose equivalent was increased compared to open field. It can be concluded that an external wedge, made from heavy materials may act like the other components of linac head, producing undesired photoneutrons and thus increasing patient dose.
Źródło:
Nukleonika; 2011, 56, 1; 49-51
0029-5922
1508-5791
Pojawia się w:
Nukleonika
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-2 z 2

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies