Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "Silva, A.C." wg kryterium: Wszystkie pola


Wyświetlanie 1-5 z 5
Tytuł:
Radiation processing of detergents and possible environmental benefits
Autorzy:
Borrely, S. I.
Romanelli, M. F.
Pereira, M. C. C.
da Silva, G. P.
Mesquita, L. C. A.
de Moraes, M. C. F.
Powiązania:
https://bibliotekanauki.pl/articles/148020.pdf
Data publikacji:
2009
Wydawca:
Instytut Chemii i Techniki Jądrowej
Tematy:
EB irradiadion
anionic surfactants
effluent
Vibrio fischeri
Daphnia similis
Opis:
Detergents at waters inducing negative changes for biological degradability and water general quality. Some authors have evidenced a considerable amount of anionic surfactant and toxic effects into natural water and effluents related to detergents. The objective of the study was to apply electron irradiation for reducing toxicity, and for degradation of surfactants. To quantify surfactant LAS determination as MBAS (metylene blue active substances) was applied. The capacity of radiation to reduce surfactants was evidenced for real effluent and for water solution containing sodium dodecyl sulfate, linear alkylbenzene sulfonate (LAS), separately. An electron beam accelerator (EBA) 1.5 MeV was the radiation source. Anionic surfactant solutions as well as real effluents resulted in less toxic samples after irradiation. Toxicity was evaluated for Vibrio fischeri and Daphnia similis. An important decline of total anionic surfactant was observed after irradiation to doses: 6.0 kGy and 20 kGy (surfactant in water solutions and effluents, respectively). To conclude, EBA irradiations accounted for 88% to 96% less toxic surfactants solutions and effluents and 68% to 96% for MBAS compounds decomposition.
Źródło:
Nukleonika; 2009, 54, 2; 61-64
0029-5922
1508-5791
Pojawia się w:
Nukleonika
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Development and production of radioactive sources used for cancer treatment in Brazil
Autorzy:
Rostelato, M. E. C. M.
Rela, P. R.
Zeituni, C. A.
Feher, A.
Manzoli, J. E.
Moura, J. A.
Moura, E. S.
Silva, C. P. G.
Powiązania:
https://bibliotekanauki.pl/articles/148305.pdf
Data publikacji:
2008
Wydawca:
Instytut Chemii i Techniki Jądrowej
Tematy:
radioactive sources production
iodine-125 seeds
iridium-192 wires
brachytherapy
cancer treatment
Opis:
The number of cancer patients in Brazil is increasing and part of the patients are submitted to brachytherapy treatment using iridium-192 wire and iodine-125 radioactive seeds. The Nuclear Energy Research Institute established a programme to produce iridium-192 wire and iodine-125 radioactive seeds. With the purpose of settling a laboratory for iridium-192 sources production, a wire activation method was developed and a hot cell for the wire manipulation, quality assurance and packaging was built. The iodine-125 seeds consist of a welded titanium capsule containing iodine-125 adsorbed onto a silver rod. Concerning the setup of the local production, the following activities were carried out: superficial treatment of the silver rod, development of a process to absorb the iodine in the silver rod, welding methodology to seal the seeds, leakage and contamination test and source activity measurement.
Źródło:
Nukleonika; 2008, 53, suppl. 2; 99-103
0029-5922
1508-5791
Pojawia się w:
Nukleonika
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Radiation-induced cancer risk and decision-making in a simulated Cs-137 urban event
Autorzy:
Andrade, Edson R.
Gomes, Renato G.
Stenders, Ricardo
Brum, Tercio
Lima, Sergio X.
Castro, Mariana S. C.
Silva, Ademir X.
Powiązania:
https://bibliotekanauki.pl/articles/146858.pdf
Data publikacji:
2020
Wydawca:
Instytut Chemii i Techniki Jądrowej
Tematy:
environmental contamination
dispersive device
decision-making
Opis:
The triggering of a “dirty bomb” generates a complex scenario, with enormous challenges for the responders due to initial misinformation and the urgency to act quickly yet effectively. Normally, the first 100 h are decisive for perceiving the risk in a more realistic dimension, but the support of methodologies that rely on computational simulations can be valuable when making key decisions. This work seeks to provide support for the early decision-making process by using a Gaussian model for the distribution of a quantity of Cs-137 spread by a radiological dispersive device (RDD). By sequentially joining two independent programs, HotSpot Health Physics codes and RESidual RADiation (RESRAD)-RDD family of codes, we came up with results that suggest a segmented approach to the potentially affected population. These results advocate that (a) the atmospheric stability conditions represented by the Pasquill–Gifford classes and (b) the population subgroups defi ned by radiation exposure conditions strongly influence the postdetonation radiological effects. These variables should be taken into account in the elaboration of flexible strategies that include many climatic conditions and to prioritize attention to different groups of public at risk. During the initial phases of such an event, it is believed that simulations using Gaussian models may be of value in anticipating the possible changes in key variables during the decision-making process. These variables may severely affect the effectiveness of the actions of responders and the general public’s safety.
Źródło:
Nukleonika; 2020, 65, 1; 37-43
0029-5922
1508-5791
Pojawia się w:
Nukleonika
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Development of an irradiation system for a small size continuous run multipurpose gamma irradiator
Autorzy:
Calvo, W. A. P.
Rela, P. R.
Napolitano, C. M.
Kodama, Y.
Omi, N. M.
da Costa, F.
de Andrade e Silva, L. G.
Powiązania:
https://bibliotekanauki.pl/articles/148041.pdf
Data publikacji:
2009
Wydawca:
Instytut Chemii i Techniki Jądrowej
Tematy:
multipurpose irradiator
gamma irradiator
compact irradiator
cobalt-60 irradiator
gamma facility
Opis:
The Radiation Technology Center from IPEN-CNEN/SP, Brazil, developed a revolutionary design and national technology, a small-sized continuous run and multipurpose industrial gamma irradiator, to be used as a demonstration facility for manufacturers and contract service companies, which need economical and logistical in-house irradiation system alternatives. Also, to be useful for supporting the local scientific community on development of products and process using gamma radiation, assisting the traditional and potential users on process validation, training and qualification of operators and radioprotection officers. The developed technology for this facility consists of a continuous tote box transport system, comprising a single concrete vault, where the automated transport system of products inside and outside of the irradiator utilizes a rotating door, integrated with the shielding, avoiding the traditional maze configuration. Covering 76 m2 of floor area, the irradiator design is a product overlap sources and the maximum capacity of cobalt-60 wet sources is 37 PBq. The performed qualification program of this multipurpose irradiator was based on AAMI/ISO 11137 standard, which recommends the inclusion of the following elements: installation and process qualification. The initial load of the multipurpose irradiator was 3.4 PBq with 13 cobalt-60 sources model C-188, supplied by MDS Nordion – Canada. For irradiator dose optimization, the source distribution was done using the software Cadgamma developed by IPEN-CNEN/SP. The polymethylmetacrylate (PMMA) dosimeter system, certified by the International Dose Assurance Service (IDAS) of the International Atomic Energy Agency (IAEA) was used for irradiator dose mapping. The economic analysis, performance concerning with dose uniformity and cobalt-60 utilization efficiency were calculated and compared with other commercial gamma irradiators available on the market.
Źródło:
Nukleonika; 2009, 54, 2; 93-97
0029-5922
1508-5791
Pojawia się w:
Nukleonika
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Estimation of ISTTOK runaway - electrons energies by means of a Cherenkov - type probe with modified AlN radiators
Autorzy:
Jakubowski, L.
Plyusnin, V. V.
Sadowski, M. J.
Zebrowski, J.
Malinowski, K.
Rabiński, M.
Fernandes, H.
Silva, C.
Duarte, P.
Jakubowski, M.
Powiązania:
https://bibliotekanauki.pl/articles/147516.pdf
Data publikacji:
2012
Wydawca:
Instytut Chemii i Techniki Jądrowej
Tematy:
ISTTOK
runaway electrons
Cherenkov detector
AlN radiators
Opis:
Measurements of fast electrons, as performed during recent few years in small tokamaks, demonstrated that detectors based on the Cherenkov effect are very useful tools for such studies. The modernized measuring heads, which were equipped with miniature aluminum-nitride (AlN) radiators, enabled to determine locations and instants of the fast electrons emission and to estimate their energy. A comparison of four measuring channels showed that in ISTTOK the most important role was played by electrons of energy less than 90 keV.
Źródło:
Nukleonika; 2012, 57, 2; 177-181
0029-5922
1508-5791
Pojawia się w:
Nukleonika
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-5 z 5

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies