Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "B[a]P" wg kryterium: Wszystkie pola


Tytuł:
Status report of the VINCY Cyclotron
Autorzy:
Nešković, N.
Ristić-Ðurović, J.
Vorojtsov, S. B.
Belicev, P.
Ivanenko, I. A.
Ćirković, S.
Vorozhtsov, A. S.
Bojović, B.
Dobrosavljević, A.
Vujović, V.
Comor, J. j.
Pajović, S. B.
Powiązania:
https://bibliotekanauki.pl/articles/146191.pdf
Data publikacji:
2003
Wydawca:
Instytut Chemii i Techniki Jądrowej
Tematy:
accelerators
cyclotrons
ion sources
radioisotopes
radiation research
Opis:
The VINCY Cyclotron is the main part of the TESLA Accelerator Installation. The diameter of the pole of this machine is 2000 mm. Its bending constant is 145 MeV while its focusing constant is 75 MeV. The radiofrequency system of the machine consists of two l/4-resonators with the eigenfrequency in the range from 17 to 31 MHz. Ions coming from a heavy ion source or a light ion source will be injected into the machine axially. They will be introduced into its median plane by a spiral inflector. Heavy ions accelerated in the machine will be extracted from it by a foil stripping system or by an electrostatic deflection system. Light ions will be extracted from it by the foil stripping system. The first programs of use of the VINCY Cyclotron are related to routine and experimental production of radioisotopes and radiopharmaceuticals, and to biomedical research with ion beams. The first beam extracted from the machine will be the proton beam of the energy of 22 MeV obtained from the H2+ beam extracted from the light ion source. This beam will be used first for production of radioisotope 18F and radio-pharmaceutical 18FDG, to be employed for positron emission tomography
Źródło:
Nukleonika; 2003, 48,suppl.2; 135-139
0029-5922
1508-5791
Pojawia się w:
Nukleonika
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
A gauge for measuring the dose rate and activity of ophthalmic applicators
Autorzy:
Machaj, B.
Awistowski, E.
Do, H.
Bilski, P.
Olko, P.
Powiązania:
https://bibliotekanauki.pl/articles/147042.pdf
Data publikacji:
2002
Wydawca:
Instytut Chemii i Techniki Jądrowej
Tematy:
dose rate
measurements
106Ru ophthalmic applicators
Opis:
A gauge was developed for determining the dose rate distribution and surface activity of ophthalmic brachytherapy applicators, particularly for 106Ru applicators. A plastic fi 2×2 mm scintillator is used as the radiation detector, featuring a high pulse count rate, which results in a low 0.5% random error, due to good counting statistics. Automatic gain control of the photomultiplier tube (PMT) is achieved using a LED as the reference light source. The PMT operates in pulse mode. Long term gain variation due to fatigue of the PMT or ambient temperature variation is thus compensated for. The count rate error due to inaccurate setting of the high voltage supply of the PMT is 0.4%, and the instability error over 7 hours of continuous operation does not exceed 1-2%, peak-to-peak.
Źródło:
Nukleonika; 2002, 47, 3; 107-111
0029-5922
1508-5791
Pojawia się w:
Nukleonika
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Plasma Focus as a lens for intense ion beam focusing
Autorzy:
Belan, V. N..
Butenko, V. I.
Ivanov, B. I.
Kiseleva, V. A.
Kitsenko, A. B.
Linnik, A. F.
Maslov, V. I.
Onishchenko, I. N.
Prishchepov, V. P.
Yegorov, A. M.
Powiązania:
https://bibliotekanauki.pl/articles/147316.pdf
Data publikacji:
2001
Wydawca:
Instytut Chemii i Techniki Jądrowej
Tematy:
intense MeV proton beam accelerator
plasma focus
plasma lens
Opis:
Experimental investigations were performed to evaluate the focusing properties of the plasma focus for high-energy intense ion beams manipulating. Magnetic probes and optical spectroscopy were used for temporal and spatial plasma geometry investigations. Ion beam portrait was determined at the luminescence screen. In the experiments performed, the focusing coefficient was obtained as the ten times beam compression at the 30 cm length. By variations of the gas volume input, gun voltage, time delay, magnetic field value etc. the dependence of focused ion beam diameter upon various parameters of the plasma focus lens has been investigated. It was revealed that the main focusing effect was caused by the azimuthal magnetic field of the currents carried by the plasma.
Źródło:
Nukleonika; 2001, 46, suppl. 1; 35-36
0029-5922
1508-5791
Pojawia się w:
Nukleonika
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Searches for discrete symmetries violation in ortho-positronium decay using the J-PET detector
Autorzy:
Kamińska, D.
Gajos, A.
Czerwiński, E.
Bednarski, T.
Białas, P.
Gorgol, M.
Jasińska, B.
Kapłon, Ł.
Korcyl, G.
Kowalski, P.
Kozik, T.
Krzemień, W.
Kubicz, E.
Niedźwiecki, S.
Pałka, M.
Raczyński, L.
Rudy, Z.
Rundel, O.
Sharma, N. G.
Silarski, M.
Słomski, A.
Strzelecki, A.
Wieczorek, A.
Wiślicki, W.
Zieliński, M.
Zgardzińska, B.
Moskal, P.
Powiązania:
https://bibliotekanauki.pl/articles/147408.pdf
Data publikacji:
2015
Wydawca:
Instytut Chemii i Techniki Jądrowej
Tematy:
discrete symmetries
J-PET
ortho-positronium
Opis:
In this paper, we present prospects for using the Jagiellonian positron emission tomograph (J-PET) detector to search for discrete symmetries violations in a purely leptonic system of the positronium atom. We discuss tests of CP and CPT symmetries by means of ortho-positronium decays into three photons. No zero expectation values for chosen correlations between ortho-positronium spin and momentum vectors of photons would imply the existence of physics phenomena beyond the standard model. Previous measurements resulted in violation amplitude parameters for CP and CPT symmetries consistent with zero, with an uncertainty of about 10−3. The J-PET detector allows to determine those values with better precision, thanks to the unique time and angular resolution combined with a high geometrical acceptance. Achieving the aforementioned is possible because of the application of polymer scintillators instead of crystals as detectors of annihilation quanta.
Źródło:
Nukleonika; 2015, 60, No. 4, part 1; 729-732
0029-5922
1508-5791
Pojawia się w:
Nukleonika
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Reconstruction of hit time and hit position of annihilation quanta in the J-PET detector using the Mahalanobis distance
Autorzy:
Sharma, N. G.
Silarski, M.
Bednarski, T.
Białas, P.
Czerwiński, E.
Gajos, A.
Gorgol, M.
Jasińska, B.
Kamińska, D.
Kapłon, Ł.
Korcyl, G.
Kowalski, P.
Kozik, T.
Krzemień, W.
Kubicz, E.
Niedźwiecki, S.
Pałka, M.
Raczyński, L.
Rudy, Z.
Rundel, O.
Słomski, A.
Strzelecki, A.
Wieczorek, A.
Wiślicki, W.
Zieliński, M.
Zgardzińska, B.
Moskal, P.
Powiązania:
https://bibliotekanauki.pl/articles/146937.pdf
Data publikacji:
2015
Wydawca:
Instytut Chemii i Techniki Jądrowej
Tematy:
J-PET detector
Mahalanobis distance
time resolution
threshold levels
Opis:
The J-PET detector being developed at the Jagiellonian University is a positron emission tomograph composed of the long strips of polymer scintillators. At the same time, it is a detector system that will be used for studies of the decays of positronium atoms. The shape of photomultiplier signals depends on the hit time and hit position of the gamma quantum. In order to take advantage of this fact, a dedicated sampling front-end electronics that enables to sample signals in voltage domain with the time precision of about 20 ps and novel reconstruction method based on the comparison of examined signal with the model signals stored in the library has been developed. As a measure of the similarity, we use the Mahalanobis distance. The achievable position and time resolution depend on the number and values of the threshold levels at which the signal is sampled. A reconstruction method as well as preliminary results are presented and discussed.
Źródło:
Nukleonika; 2015, 60, No. 4, part 1; 765-769
0029-5922
1508-5791
Pojawia się w:
Nukleonika
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
PALS investigations of free volumes thermal expansion of J-PET plastic scintillator synthesized in polystyrene matrix
Autorzy:
Wieczorek, A.
Zgardzińska, B.
Jasińska, B.
Gorgol, M.
Bednarski, T.
Białas, P.
Czerwiński, E.
Gajos, A.
Kamińska, D.
Kapłon, Ł.
Kochanowski, A.
Korcyl, G.
Kowalski, P.
Kozik, T.
Krzemień, W.
Kubicz, E.
Niedźwiecki, S.
Pałka, M.
Raczyński, L.
Rudy, Z.
Rundel, O.
Sharma, N. G.
Silarski, M.
Silarski, A.
Strzelecki, A.
Wiślicki, W.
Zieliński, M.
Moskal, P.
Powiązania:
https://bibliotekanauki.pl/articles/147132.pdf
Data publikacji:
2015
Wydawca:
Instytut Chemii i Techniki Jądrowej
Tematy:
free volume
positron annihilation
polystyrene
positronium
scintillator
Opis:
The polystyrene doped with 2,5-diphenyloxazole as a primary fluor and 2-(4-styrylphenyl)benzoxazole as a wavelength shifter prepared as a plastic scintillator was investigated using positronium probe in wide range of temperatures from 123 to 423 K. Three structural transitions at 260, 283, and 370 K were found in the material. In the o-Ps intensity dependence on temperature, the significant hysteresis is observed. Heated to 370 K, the material exhibits the o-Ps intensity variations in time.
Źródło:
Nukleonika; 2015, 60, No. 4, part 1; 777-781
0029-5922
1508-5791
Pojawia się w:
Nukleonika
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Processing optimization with parallel computing for the J-PET scanner
Autorzy:
Krzemień, W.
Bała, M.
Bednarski, T.
Białas, P.
Czerwiński, E.
Gajos, A.
Gorgol, M.
Jasińska, B.
Kamińska, D.
Kapłon, Ł.
Korcyl, G.
Kowalski, P.
Kozik, T.
Kubicz, E.
Niedźwiecki, S.
Pałka, M.
Raczyński, L.
Rudy, Z.
Rundel, O.
Sharma, N. G.
Silarski, M.
Słomski, A.
Stola, K.
Strzelecki, A.
Trybek, D.
Wieczorek, A.
Wiślicki, W.
Zieliński, M.
Zgardzińska, B.
Moskal, P.
Powiązania:
https://bibliotekanauki.pl/articles/148285.pdf
Data publikacji:
2015
Wydawca:
Instytut Chemii i Techniki Jądrowej
Tematy:
data aquisition system (DAQ)
parallel computing
TOF-PET
Opis:
The Jagiellonian Positron Emission Tomograph (J-PET) collaboration is developing a prototype time of flight (TOF)-positron emission tomograph (PET) detector based on long polymer scintillators. This novel approach exploits the excellent time properties of the plastic scintillators, which permit very precise time measurements. The very fast fi eld programmable gate array (FPGA)-based front-end electronics and the data acquisition system, as well as low- and high-level reconstruction algorithms were specially developed to be used with the J-PET scanner. The TOF-PET data processing and reconstruction are time and resource demanding operations, especially in the case of a large acceptance detector that works in triggerless data acquisition mode. In this article, we discuss the parallel computing methods applied to optimize the data processing for the J-PET detector. We begin with general concepts of parallel computing and then we discuss several applications of those techniques in the J-PET data processing.
Źródło:
Nukleonika; 2015, 60, No. 4, part 1; 745-748
0029-5922
1508-5791
Pojawia się w:
Nukleonika
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Search for canted spin arrangement in Er2-xTbxFe14B with Mössbauer spectroscopy
Autorzy:
Kurzydło, P. M.
Bogacz, B. F.
Pędziwiatr, A. T.
Oleszak, D.
Przewoźnik, J.
Powiązania:
https://bibliotekanauki.pl/articles/147036.pdf
Data publikacji:
2015
Wydawca:
Instytut Chemii i Techniki Jądrowej
Tematy:
Mössbauer effect
permanent magnet materials
spin diagrams
spin reorientation
Opis:
The materials studied were polycrystalline compounds Er2-xTbxFe14B (x = 0.1, 0.2, 0.3, 0.4) which crystallize in a tetragonal lattice and display a variety of spin arrangements. The compounds have been measured with 57Fe Mössbauer spectroscopy over the temperature range 80–320 K in order to investigate the spin reorientation processes. Each compound was studied in a wide temperature range, with precise Mössbauer scanning in the vicinity of the transition. The set of spectra obtained for a given compound was analyzed using simultaneous fi tting procedure to investigate the infl uence of the transition on the shape of the spectra. The fi tting program was specifi ed to analyze the transition according to the ‘two state model’: spins fl ip abruptly from initial angle to fi nal arrangement (90° angle). Obtained results suggest that spin reorientation process cannot be described using only the mentioned above model. Additional computer simulations based on the Yamada–Kato model were conducted to determine temperature range and the type of spin alignments in the vicinity of the transition. These theoretical results supported by spectra analysis suggest the existence of intermediate (canted) spin arrangements in the studied compounds. The spin arrangement diagram was constructed.
Źródło:
Nukleonika; 2015, 60, 1; 93-96
0029-5922
1508-5791
Pojawia się w:
Nukleonika
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Studies of unicellular microorganisms Saccharomyces cerevisiae by means of positron annihilation lifetime spectroscopy
Autorzy:
Kubicz, E.
Jasińska, B.
Zgardzińska, B.
Bednarski, T.
Białas, P.
Czerwiński, E.
Gajos, A.
Gorgol, M.
Kamińska, D.
Kapłon, Ł.
Kochanowski, A.
Korcyl, G.
Kowalski, P.
Kozik, T.
Krzemień, W.
Niedźwiecki, S.
Pałka, M.
Raczyński, L.
Rajfur, Z.
Rudy, Z.
Rundel, O.
Sharma, N. G.
Silarski, M.
Słomski, A.
Strzelecki, A.
Wieczorek, A.
Wiślicki, W.
Zieliński, M.
Moskal, P.
Powiązania:
https://bibliotekanauki.pl/articles/147902.pdf
Data publikacji:
2015
Wydawca:
Instytut Chemii i Techniki Jądrowej
Tematy:
environmental scanning electron microscopy (ESEM)
free volume
inverted microscopy
positron annihilation
positronium
yeasts
Opis:
Results of positron annihilation lifetime spectroscopy (PALS) and microscopic studies on simple microorganisms, brewing yeasts, are presented. Lifetime of ortho-positronium (o-Ps) were found to change from 2.4 to 2.9 ns (longer-lived component) for lyophilized and aqueous yeasts, respectively. Also hygroscopicity of yeasts in time was examined, allowing to check how water – the main component of the cell – affects PALS parameters, thus lifetime of o-Ps were found to change from 1.2 to 1.4 ns (shorter-lived component) for the dried yeasts. The time sufficient to hydrate the cells was found below 10 hours. In the presence of liquid water, an indication of reorganization of yeast in the molecular scale was observed. Microscopic images of the lyophilized, dried, and wet yeasts with best possible resolution were obtained using inverted microscopy (IM) and environmental scanning electron microscopy (ESEM) methods. As a result, visible changes to the surface of the cell me mbrane were observed in ESEM images.
Źródło:
Nukleonika; 2015, 60, No. 4, part 1; 749-753
0029-5922
1508-5791
Pojawia się w:
Nukleonika
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Spin reorientation process in Tm2–xHoxFe14B : analysis of conical arrangement based on Mössbauer spectra
Autorzy:
Kurzydło, P. M.
Pędziwiatr, A. T.
Bogacz, B. F.
Przewoźnik, J.
Oleszak, D.
Powiązania:
https://bibliotekanauki.pl/articles/148120.pdf
Data publikacji:
2017
Wydawca:
Instytut Chemii i Techniki Jądrowej
Tematy:
permanent magnetic materials
Mössbauer effect
spin reorientation
spin diagrams
Opis:
The spin reorientation process in the Tm2–xHoxFe14B series of compounds was studied using 57Fe Mössbauer spectroscopy over the temperature range 5.2–320 K with a focus on the analysis of conical spin arrangement. Each compound was studied by precise Mössbauer scanning in the vicinity of the transition and during the transition. By applying computer simulations based on the simplified Yamada-Kato model, as well as on some literature data for R2Fe14B (R = Tm, Ho) compounds, the above series was selected for studies as it contains compounds with different spin arrangements (axial, planar, conical). It was a crucial requirement for obtaining unambiguous angular dependences when applying a simultaneous fitting procedure of Mössbauer spectra. Such an extended procedure was applied which allowed the temperature dependence of the angle describing the position of the magnetization vector to be obtained. The results were compared with those from theoretical simulations. The spin arrangement diagram was constructed. A conical spin arrangement was confirmed over a wide temperature range.
Źródło:
Nukleonika; 2017, 62, 2; 123-127
0029-5922
1508-5791
Pojawia się w:
Nukleonika
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Measurement of radon (222Rn) and thoron (220Rn) concentration with a single scintillation cell
Autorzy:
Machaj, B.
Urbański, P.
Bartak, J.
Powiązania:
https://bibliotekanauki.pl/articles/146829.pdf
Data publikacji:
2007
Wydawca:
Instytut Chemii i Techniki Jądrowej
Tematy:
radon
thoron
measurement
scintillation cell
Opis:
. A single scintillation cell (ö 54 × 74 mm) is used for the measurement of radon and thoron. The radon and thoron laden air is filtered and forced to flow at 1 dm3/min through the scintillation cell in the period of 1 10 min. The count number from alpha radiation is registered in the periods of 3 10 min and 20 30 min. Two values of detection and deposition efficiency of alpha radiation are used for radon (at air flow and air at rest in the cell) and for thoron. Measurements of radon laden air and thoron laden air showed good agreement between the reference concentration and the measured concentration, not worse than 1% for radon and not worse than 2% for thoron. Combination of radon + thoron concentration showed also a small interference ("cross talk") not worse than 1%.
Źródło:
Nukleonika; 2007, 52, 4; 167-171
0029-5922
1508-5791
Pojawia się w:
Nukleonika
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
A study of the photoneutron dose equivalent resulting from a Saturne 20 medical linac using Monte Carlo method
Autorzy:
Hashemi, F.
Hashemi-Malayeri, B.
Raisali, G.
Shokrani, P.
Sharafi, A.
Powiązania:
https://bibliotekanauki.pl/articles/148191.pdf
Data publikacji:
2007
Wydawca:
Instytut Chemii i Techniki Jądrowej
Tematy:
photoneutron
linac
Monte Carlo method
MCNP4C
dose equivalent
Opis:
High energy linacs have several advantages including lower skin dose and higher dose rate at deep sighted tumors. But, at higher energies photonuclear reactions produce neutron contamination. Photoneutron contamination has been investigated from the early days of modern linacs. However, more studies have become possible using Monte Carlo codes developed in recent years. The aim of this study was to investigate the photoneutron spectrum and dose equivalent produced by an 18 MV Saturne linac at different points of a treatment room and its maze. The MCNP4C code was used to simulate the transport of photoneutrons produced by a typical 18 MV Saturne linac. The treatment room of a radiotherapy facility in which a Saturne 20 linac is installed was modeled. Neutron dose equivalent was calculated and its variations at various distances from the center of the X-ray beam was studied. It was noted that by increasing the distance from the center of the beam, fast neutrons decrease rapidly, but thermal neutrons do not change significantly. In addition, the photoneutron dose equivalent was lower for smaller fields. The fast photoneutrons were not recorded in the maze. It can be concluded that the fast photoneutrons are highly attenuated by concrete barrier, while the slow photoneutrons are increased. In addition, increasing the X-ray field size increases the photoneutron dose equivalent around the treatment room and maze. It seems that the walls play an effective role in increasing the photoneutron dose equivalent.
Źródło:
Nukleonika; 2007, 52, 1; 39-43
0029-5922
1508-5791
Pojawia się w:
Nukleonika
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Metrological features of a beta absorption particulate air monitor operating with wireless communication system
Autorzy:
Jakowiuk, A.
Urbański, P.
Świstowski, E.
Machaj, B.
Pieńkos, J.
Kowalska, E.
Powiązania:
https://bibliotekanauki.pl/articles/146846.pdf
Data publikacji:
2008
Wydawca:
Instytut Chemii i Techniki Jądrowej
Tematy:
ambient air
beta-ray absorption
particulate matter
wireless communication
Opis:
A system for measurements of particulate matter in the ambient air, employing beta absorption instrument AMIZ-2007 with wireless communication facilities based on GPRS technology, is presented. Uncertainty of measurements caused by the counting statistics was analyzed and it was found that at least 3 h of sampling time is needed to achieve coefficient of variation lower than 20% for the average concentration of particulate matter in the ambient air exceeding 10 μg/m3. Application of a C-14 beta ray source instead of Pm-147 improves sensitivity of the measurement ca. two times. Some results of on-line operation of the system with PM10 and PM2.5 samplers are also shown.
Źródło:
Nukleonika; 2008, 53, suppl. 2; 37-42
0029-5922
1508-5791
Pojawia się w:
Nukleonika
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
X-ray diffraction, Mössbauer spectroscopy, and magnetoelectric effect studies of (BiFeO3)x-(BaTiO3)1-x solid solutions
Autorzy:
Kowal, K.
Jartych, E.
Guzdek, P.
Stoch, P.
Wodecka-Duś, B.
Lisińska-Czekaj, A.
Czekaj, D.
Powiązania:
https://bibliotekanauki.pl/articles/147352.pdf
Data publikacji:
2013
Wydawca:
Instytut Chemii i Techniki Jądrowej
Tematy:
multiferroics
hyperfine interactions
Mössbauer spectroscopy
magnetoelectric effect
Opis:
In this work the hyperfine interactions in (BiFeO3)x-(BaTiO3)1-x solid solutions with relation to their structural properties have been investigated. X-ray diffraction, Mössbauer spectroscopy and magnetoelectric effect measurements have been used for studies of sintered (BiFeO3)x-(BaTiO3)1-x solid solutions with x = 0.9, 0.8 and 0.7. With increasing contents of BaTiO3, the structural transformation from rhombohedral to cubic was observed. The weakening of the hyperfine magnetic fields accompanied by this transformation. On the other hand, the increasing amount of BaTiO3 caused an increase of the magnetoelectric effect.
Źródło:
Nukleonika; 2013, 58, 1; 57-61
0029-5922
1508-5791
Pojawia się w:
Nukleonika
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Dictyonema black shale and Triassic sandstones as potential sources of uranium
Autorzy:
Kiegiel, K.
Zakrzewska-Kołtuniewicz, G.
Gajda, D.
Miśkiewicz, A.
Abramowska, A.
Biełuszka, P.
Danko, B.
Chajduk, E.
Wołkowicz, S.
Powiązania:
https://bibliotekanauki.pl/articles/147500.pdf
Data publikacji:
2015
Wydawca:
Instytut Chemii i Techniki Jądrowej
Tematy:
uranium ores
leaching
extraction
ion-exchange chromatography
precipitation
Opis:
The main objective of the present study was an assessment of the possibility of uranium recovery from domestic resources in Poland. In the fi rst stage uranium was leached from the ground uranium ore by using acidic (sulfuric acid or hydrochloric acid) or alkaline (carbonate) solutions. The leaching efficiencies of uranium were dependent on the type of ore and it reached 81% for Dictyonemic shales and almost 100% for sandstones. The novel leaching routes, with the application of the helical membrane contactor equipped with rotating part were tested. The obtained postleaching solutions were concentrated and purifi ed using solvent extraction or ion exchange chromatography. New methods of solvent extraction, as well as hybrid processes for separation and purifi cation of the product, were studied. Extraction with the use of membrane capillary contactors that has many advantages above conventional methods was also proposed as an alternative purification method. The fi nal product U3O8 could be obtained by the precipitation of ‘yellow cake’, followed by calcination step. The results of precipitation of ammonium diuranate and uranium peroxide from diluted uranium solution were presented.
Źródło:
Nukleonika; 2015, 60, No. 3, part 2; 515-522
0029-5922
1508-5791
Pojawia się w:
Nukleonika
Dostawca treści:
Biblioteka Nauki
Artykuł

Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies