Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "gamma radiation" wg kryterium: Temat


Wyświetlanie 1-3 z 3
Tytuł:
Analysis of influence of environmental conditions and natural gamma radiation for radon concentration measurements
Analiza wpływu warunków środowiskowych oraz naturalnej promieniotwórczości gamma na wyniki pomiarów koncentracji radonu
Autorzy:
Skupio, R.
Kowalska, S.
Jankowski, L.
Powiązania:
https://bibliotekanauki.pl/articles/1835256.pdf
Data publikacji:
2018
Wydawca:
Instytut Nafty i Gazu - Państwowy Instytut Badawczy
Tematy:
radon
environmental conditions
gamma radiation
spectrometry
warunki środowiskowe
promieniowanie gamma
spektrometria
Opis:
The influence of environmental conditions and natural gamma radiation of rocks nearby measurement points has been introduced in this paper to radon concentration measurements in soil air. Our studies helped to assess anomalies caused by major tectonic zones that occurring in the Carpathians. These anomalies, can be used for interpretation and location of potential zones for oil and gas industry. Environmental tests had to be conducted because of the introduction of new measurement methodology within evaluation of statistical measurement errors and specific tests conditions. Stationary work was carried out in a limited area nearby Bagrowa st., Krakow, fieldwork was carried out at the Cergowa Mountain–Krosno profile. The conducted research did not show the influence of air humidity, precipitation, air temperature, air pressure and natural radioactive elements (K-40, U-238 and Th232) on the measured radon anomalies. In this study RAD7 spectrometer with a soil probe was used.
W pracy przedstawiono wpływ warunków środowiskowych i naturalnej promieniotwórczości skał występujących w otoczeniu punktów pomiarowych, na wyniki badań koncentracji radonu w powietrzu glebowym. Badania radonu pozwalają na identyfikację anomalii powodowanych występowaniem głównych stref uskokowych w Karpatach, co może pomóc wyznaczyć lokalizację występowania obszarów o potencjale dla poszukiwań przemysłu naftowego. Konieczność przeprowadzenia testów związana jest z opracowaniem nowej metodyki, która wymagała oceny błędów pomiarowych oraz warunków, w jakich należy prowadzić badania. Prace stacjonarne wykonane zostały w obrębie ograniczonej powierzchni w Krakowie przy ul. Bagrowej, prace terenowe przeprowadzono na profilu Góra Cergowa–Krosno. Badania nie ukazały wpływu wilgotności powietrza, opadów atmosferycznych, temperatury powietrza, ciśnienia atmosferycznego oraz naturalnych pierwiastków promieniotwórczych (K-40, U-238, Th-232) na mierzone anomalie radonowe. Do przeprowadzenia badań wykorzystano aparaturę badawczą w postaci spektrometru RAD7 wraz z sondą do pomiarów gazu w powietrzu glebowym.
Źródło:
Nafta-Gaz; 2018, 74, 8; 584-591
0867-8871
Pojawia się w:
Nafta-Gaz
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Spektrometryczne pomiary gamma rdzeni wiertniczych o niskiej aktywności
Spectrometric gamma measurements of low radioactivity cores
Autorzy:
Skupio, Rafał
Wolański, Krzysztof
Powiązania:
https://bibliotekanauki.pl/articles/1835068.pdf
Data publikacji:
2019
Wydawca:
Instytut Nafty i Gazu - Państwowy Instytut Badawczy
Tematy:
promieniowanie gamma
pomiary rdzeni
radiometria
spektrometria
gamma radiation
core measurements
radiometry
spectrometry
Opis:
W pracy przedstawiono nową metodykę pomiarową spektrometrii gamma dla rdzeni wiertniczych reprezentowanych przez skały o niskiej aktywności. Opisano w niej części składowe nowo zaprojektowanego spektrometru wraz z dedykowanym oprogramowaniem testowym. Badania prowadzone według zaproponowanej procedury stosowane są głównie do rdzeni formacji piaskowcowych czerwonego spągowca, dla których dotychczas w Polsce nie wykonywano pomiarów gamma. Pierwsze testy na rdzeniach piaskowcowych prowadzono z wykorzystaniem standardowego spektrometru – gamma logger BGO (GL), przy wydłużonym czasie pomiarowym, co pozwoliło uzyskać zaledwie częściowe wyniki dla wybranego odcinka rdzenia. Opracowanie nowego urządzenia wykorzystującego dwa niezależnie mierzące detektory BGO, umieszczone pod kątem 90 stopni w ołowianym tunelu (aparatura GLGT) umożliwiło dwukrotne skrócenie czasu pomiarowego, poprawienie dokładności wyników oraz obniżenie poziomu detekcji dla analizowanych pierwiastków (potas, uran oraz tor). Wstępne badania porównawcze w otworze testowym ukazały różnice pomiędzy aparatem GL i GLGT. Polegały one na poprawie jakości rejestrowanych danych w szczególności dla uranu i toru, które w przypadku standardowych analiz przyjmowały wartości mniejsze od tła pomiarowego. Dodatkowe badania przeprowadzono na wzorcach kalibracyjnych w postaci walca o znanej koncentracji pierwiastków promieniotwórczych, których wyniki posłużyły głównie do oceny rozdzielczości obu metod. Seria pomiarów rdzeni z otworu J-1 pozwoliła otrzymać dokładne wyniki porównawcze z aparatów GL i GLGT, które przedstawiono na tle profilowań geofizyki otworowej oraz badań laboratoryjnych. W przypadku tego testu wyniki z aparatury GLGT wykazały się poprawą dokładności, lepszym dopasowaniem do profilowań oraz poprawą rozdzielczości pionowej w stosunku do geofizyki wiertniczej. Uzyskane wyniki pomiarów spektrometrem GLGT wykorzystano do określenia tła pomiarowego, szacunkowej rozdzielczości oraz określenia dokładnych zawartości potasu, uranu i toru w otworach archiwalnych. Wyniki końcowe przedstawiono w postaci krzywych spektrometrycznego profilowania gamma.
This paper shows a new methodology of gamma spectrometry measurements dedicated to cores represented by rocks of low radioactivity. It describes the components of the newely developed spectrometer and the dedicated testing software. The measurements conducted according to the proposed procedure are mostly applied for Rotliegend formation cores, for which spectral gamma core logging has never been done before in Poland. The first tests on the sandstone cores were conducted using a standard spectrometer – gamma logger BGO (GL) with an extended measurement time, which allowed obtain partial results for chosen core interval. The construction of the new device, which uses two independent BGO detectors placed at a 90-degree angle in lead tunnel shielding (GLGT apparatus), made it possible to twice shorten the measurement time, improve the accuracy of the results, and reduce the detection limit for the analysed elements (potassium, uranium, thorium). Preliminary comparative studies performed on the core from the test borehole showed differences between gamma logger GL and the GLGT device. These differences were visible especially for uranium and thorium data, which in the case of standard (GL) surveys carried values that were lower than the measurement background. Additional measurements were carried out on calibration standards in the form of a cylinder with a known concentration of radioactive elements, the results of which were used for evaluating the core logging resolution of both methods. The series of core measurements from J-1 borehole allowed to obtain accurate comparative results from GL and GLGT devices, which were presented against well logging and laboratory analyses. In the case of this test, the results from GLGT apparatus showed an improvement in measurement accuracy, better fitting to the well logs, and a higher vertical resolution in relation to spectral gamma logs. The results of the measurements performed with a GLGT spectrometer were used to define the measurement background, the estimated resolution, as well as to define the accurate content of potassium, uranium and thorium in the archival boreholes. All the final results were presented as curves of spectral gamma logs.
Źródło:
Nafta-Gaz; 2019, 75, 6; 324-329
0867-8871
Pojawia się w:
Nafta-Gaz
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Pomiar gamma-gamma oraz komputerowa tomografia rentgenowska na rdzeniach wiertniczych skał osadowych
Gamma–gamma measurements and X-ray computed tomography applied to sedimentary rock cores
Autorzy:
Skupio, R.
Dohnalik, M.
Powiązania:
https://bibliotekanauki.pl/articles/1835472.pdf
Data publikacji:
2017
Wydawca:
Instytut Nafty i Gazu - Państwowy Instytut Badawczy
Tematy:
promieniowanie gamma
gęstość objętościowa
tomografia komputerowa
analiza rdzeni wiertniczych
skały osadowe
gamma radiation
bulk density
computed tomography
core analyze
sedimentary rocks
Opis:
Metody badawcze wykorzystujące absorpcję promieniowania elektromagnetycznego zostały zastosowane do ciągłych pomiarów gęstości rdzeni wiertniczych pobranych ze skał różniących się litologią oraz właściwościami petrofizycznymi. Pomiary gamma-gamma oraz tomografia komputerowa pozwalają na rejestrację profilu zmian gęstości z dużą rozdzielczością, bez ingerencji w analizowany materiał – metody nieinwazyjne. Zastosowanie badań całych rdzeni pozwoli na wprowadzenie oszczędności w budżetach firm poszukiwawczych, które często ograniczają rdzeniowanie, a przez to pomiary laboratoryjne do minimum. W przypadku występowania w badanych rdzeniach cienkich wkładek skał o odmiennej litologii, szczelin oraz żyłek kalcytowych – analizy wykonane na całym dostępnym materiale znacznie zwiększą możliwości interpretacyjne geofizyki otworowej. Do przeprowadzenia badań wykorzystano spektrometr gamma z aplikacją do pomiarów gęstości elektronowej (gamma logger core density – GLCD) oraz medyczny tomograf komputerowy z aplikacją konwertującą pliki graficzne na ciągły profil zmian gęstości wyrażonej w jednostkach Hounsfielda (computed tomography core density – CTCD). W pracy przedstawiono metodykę rejestracji parametrów oraz interpretację otrzymanych wyników.
Methods based on electromagnetic radiation absorption were applied to continuous density measurements, on rock cores of diverse lithology and petrophysical properties. Non-destructive techniques such as gamma-gamma and computed tomography measurements, allow for high resolution density core logging. Application of the proposed methods to whole core studies, helps with saving budget of companies, that reduces coring and laboratory measurements to minimum. In case of the occurrence of thin layers with different lithology, fractures or calcium veins, analysis performed on the entire available material will significantly increase the capabilities of well logging interpretation. To perform the tests, gamma spectrometer with bulk density application (gamma logger core density – GLCD) and medical tomography with an application which converts image files to continuous profile of density changes expressed in Hounsfield units (computed tomography core density – CTCD) were used. In this study the measurement method and the results interpretation technique were presented.
Źródło:
Nafta-Gaz; 2017, 73, 8; 571-582
0867-8871
Pojawia się w:
Nafta-Gaz
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-3 z 3

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies