Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "coordinate measuring" wg kryterium: Temat


Wyświetlanie 1-6 z 6
Tytuł:
Device for interim check of coordinate measuring machines
Autorzy:
Arenhart, Rodrigo Schons
Pizzolato, Morgana
Beuren, Fernanda Hänsch
Souza, Adriano Mendonça
Cantorski da Rosa, Leandro
Powiązania:
https://bibliotekanauki.pl/articles/2051859.pdf
Data publikacji:
2022
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
coordinate measuring machine
device
interim check
Opis:
This paper presents a new interim check device for coordinate measuring machines (CMMs) built from an AISI 1020 carbon steel bar with the incorporation of calibrated spheres. This artifact’s construction was made to make the interim checks of machines of this type faster and cheaper. Three devices were designed based on the ISO 10360-2 standard, the good practice guide No. 42 (NPL), and prominent authors’ research on the subject. The three options are presented in detail, but only one was built due to budget, size, and adaptability restrictions. An exploratory study was conducted to verify the device’s usability in two CMMs and concluded that the differences between the measurements are not significant. However, one machine had absolute variation values and a total standard deviation higher than the other, generating a larger expanded uncertainty.
Źródło:
Metrology and Measurement Systems; 2022, 29, 1; 143-158
0860-8229
Pojawia się w:
Metrology and Measurement Systems
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Improved calibration uncertainty assessment technique in coordinate metrology considering thermal influences
Autorzy:
Mussatayev, Meirbek
Huang, Meifa
Nurtas, Marat
Arynov, Azamat
Powiązania:
https://bibliotekanauki.pl/articles/2052177.pdf
Data publikacji:
2021
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
coordinate measuring machine
coordinate metrology
uncertainty
quality control
thermal influence
Opis:
Reliable measurement uncertainty is a crucial part of the conformance/nonconformance decision-making process in the field of Quality Control in Manufacturing. The conventional GUM-method cannot be applied to CMM measurements primarily because of lack of an analytical relationship between the input quantities and the measurement. This paper presents calibration uncertainty analysis in commercial CMM-based Coordinate Metrology. For the case study, the hole-plate calibrated by the PTB is used as a workpiece. The paper focuses on thermo-mechanical errors which immediately affect the dimensional accuracy of manufactured parts of high-precision manufacturers. Our findings have highlighted some practical issues related to the importance of maintaining thermal equilibrium before the measurement. The authors have concluded that the thermal influence as an uncertainty contributor of CMM measurement result dominates the overall budgets for this example. The improved calibration uncertainty assessment technique considering thermal influence is described in detail for the use of a wide range of CMM users.
Źródło:
Metrology and Measurement Systems; 2021, 28, 4; 609--626
0860-8229
Pojawia się w:
Metrology and Measurement Systems
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
A Statistical Approach To Prediction Of The CMM Drift Behaviour Using A Calibrated Mechanical Artefact
Autorzy:
Cuesta, E.
Alvarez, B.
Sanchez-Lasheras, F.
Gonzalez-Madruga, D.
Powiązania:
https://bibliotekanauki.pl/articles/221090.pdf
Data publikacji:
2015
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
multivariate regression models
coordinate measuring machine
drift behaviour
calibration
Opis:
This paper presents a multivariate regression predictive model of drift on the Coordinate Measuring Machine (CMM) behaviour. Evaluation tests on a CMM with a multi-step gauge were carried out following an extended version of an ISO evaluation procedure with a periodicity of at least once a week and during more than five months. This test procedure consists in measuring the gauge for several range volumes, spatial locations, distances and repetitions. The procedure, environment conditions and even the gauge have been kept invariables, so a massive measurement dataset was collected over time under high repeatability conditions. A multivariate regression analysis has revealed the main parameters that could affect the CMM behaviour, and then detected a trend on the CMM performance drift. A performance model that considers both the size of the measured dimension and the elapsed time since the last CMM calibration has been developed. This model can predict the CMM performance and measurement reliability over time and also can estimate an optimized period between calibrations for a specific measurement length or accuracy level.
Źródło:
Metrology and Measurement Systems; 2015, 22, 3; 417-428
0860-8229
Pojawia się w:
Metrology and Measurement Systems
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Evaluation of different probing systems used in articulated arm coordinate measuring machines
Autorzy:
Brau, A.
Valenzuela, M.
Santolaria, J.
Aguilar, J. J.
Powiązania:
https://bibliotekanauki.pl/articles/221100.pdf
Data publikacji:
2014
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
articulated arm coordinate measuring machine
probing systems
self-centering active probe
Opis:
This paper presents a comparison of different techniques to capture nominal data for its use in later verification and kinematic parameter identification procedures for articulated arm coordinate measuring machines (AACMM). By using four different probing systems (passive spherical probe, active spherical probe, self-centering passive probe and self-centering active probe) the accuracy and repeatability of captured points has been evaluated by comparing these points to nominal points materialized by a ball-bar gauge distributed in several positions of the measurement volume. Then, by comparing these systems it is possible to characterize the influence of the force over the final results for each of the gauge and probing system configurations. The results with each of the systems studied show the advantages and original accuracy obtained by active probes, and thus their suitability in verification (active probes) and kinematic parameter identification (self-centering active probes) procedures.
Źródło:
Metrology and Measurement Systems; 2014, 21, 2; 233-246
0860-8229
Pojawia się w:
Metrology and Measurement Systems
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Assessment of Free-Form Surfaces’ Reconstruction Accuracy
Autorzy:
Wójcik, A.
Niemczewska-Wójcik, M.
Sładek, J.
Powiązania:
https://bibliotekanauki.pl/articles/220773.pdf
Data publikacji:
2017
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
reverse engineering
accuracy assessment
free-form surface
coordinate measuring machine
radius correction
Opis:
The paper presents the problem of assessing the accuracy of reconstructing free-form surfaces in the CMM/CAD/CAM/CNC systems. The system structure comprises a coordinate measuring machine (CMM) PMM 12106 equipped with a contact scanning probe, a 3-axis Arrow 500 Vertical Machining Center, QUINDOS software and Catia software. For the purpose of surface digitalization, a radius correction algorithm was developed. The surface reconstructing errors for the presented system were assessed and analysed with respect to offset points. The accuracy assessment exhibit error values in the reconstruction of a free-form surface in a range of ± 0.02 mm, which, as it is shown by the analysis, result from a systematic error.
Źródło:
Metrology and Measurement Systems; 2017, 24, 2; 303-312
0860-8229
Pojawia się w:
Metrology and Measurement Systems
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Practical measurement strategies for verification of freeform surfaces using coordinate measuring machines
Autorzy:
Rajamohan, G.
Shunmugam, M. S.
Samuel, G. L.
Powiązania:
https://bibliotekanauki.pl/articles/220456.pdf
Data publikacji:
2011
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
freeform surface
coordinate measuring machine
machining errors
probe size
sampling strategies
substitute geometry
Opis:
Freeform surfaces have wider engineering applications. Designers use B-splines, Non-Uniform Rational Bsplines, etc. to represent the freeform surfaces in CAD, while the manufacturers employ machines with controllers based on approximating functions or splines. Different errors also creep in during machining operations. Therefore the manufactured freeform surfaces have to be verified for conformance to design specification. Different points on the surface are probed using a coordinate measuring machine and substitute geometry of surface established from the measured points is compared with the design surface. The sampling points are distributed according to different strategies. In the present work, two new strategies of distributing the points on the basis of uniform surface area and dominant points are proposed, considering the geometrical nature of the surfaces. Metrological aspects such as probe contact and margins to be provided along the sides have also been included. The results are discussed in terms of deviation between measured points and substitute surface as well as between design and substitute surfaces, and compared with those obtained with the methods reported in the literature.
Źródło:
Metrology and Measurement Systems; 2011, 18, 2; 209-222
0860-8229
Pojawia się w:
Metrology and Measurement Systems
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-6 z 6

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies