Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "coherence" wg kryterium: Temat


Wyświetlanie 1-5 z 5
Tytuł:
Wideband spectral emission measurements from laser-produced plasma EUV/SXR source based on a double gas puff target
Autorzy:
Arikkatt, Antony Jose
Wachulak, Przemysław
Fiedorowicz, Henryk
Bartnik, Andrzej
Czwartos, Joanna
Powiązania:
https://bibliotekanauki.pl/articles/1849155.pdf
Data publikacji:
2020
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
Plasma Spectroscopy
X-ray coherence tomography
soft X-ray
Opis:
We present spectral emission characteristics from laser-plasma EUV/SXR sources produced by irradiation of < 1 J energy laser pulse on eleven different double stream gas puff targets, with most intense electronic transitions identified in the spectral range from 1 nm to 70 nm wavelength which corresponds to photon energy from 18 eV to 1240 eV. The spectra were obtained using grazing incidence and transmission spectrographs from laser-produced plasma emission, formed by the interaction of a laser beam with a double stream gas puff target. Laser pulses with a duration of 4 ns and energy of 650 mJ were used for the experiment. We present the results obtained from three different spectrometers in the wavelength ranges of SXR (1-5.5 nm), SXR/EUV (4-15.5 nm), and EUV (10-70 nm). In this paper, detailed information about the source, gas targets under investigation, the experimental setup, spectral measurements and the results are presented and discussed. Such data may be useful for the identification of adequate spectral emissions from gasses in the EUV and SXR wavelength ranges dedicated to various experiments (i.e. broadband emission for the X-ray coherence tomography XCT) or may be used for verification of magnetohydrodynamic plasma codes.
Źródło:
Metrology and Measurement Systems; 2020, 27, 4; 701-719
0860-8229
Pojawia się w:
Metrology and Measurement Systems
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Measurement of retina vessels by segmentation of images reconstructed from optical coherence tomography data
Autorzy:
Marciniak, Tomasz
Stankiewicz, Agnieszka
Dąbrowski, Adam
Stopa, Marcin
Rakowicz, Piotr
Marciniak, Elżbieta
Powiązania:
https://bibliotekanauki.pl/articles/220715.pdf
Data publikacji:
2019
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
optical coherence tomography
image processing
mathematical morphology
vessel segmentation
Opis:
In this paper methods and their examination results for automatic segmentation and parameterization of vessels based on spectral domain optical coherence tomography (SD-OCT) of the retina are presented. We present three strategies for morphologic image processing of a fundus image reconstructed from OCT scans. A specificity of initial image processing for fundus reconstruction is analysed. Then, the parameterization step is performed based on the vessels segmented with the proposed algorithm. The influence of various methods on the vessel segmentation and fully automatic vessel measurement is analysed. Experiments were carried out with a set of 3D OCT scans obtained from 24 eyes (12 healthy volunteers) with the use of an Avanti RTvue OCT device. The results of automatic vessel segmentation were numerically compared with those prepared manually by the medical doctor experts.
Źródło:
Metrology and Measurement Systems; 2019, 26, 3; 449-461
0860-8229
Pojawia się w:
Metrology and Measurement Systems
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Non-destructive inspection of anti-corrosion protective coatings using optical coherent tomography
Autorzy:
Antoniuk, P.
Strąkowski, M. R.
Pluciński, J.
Kosmowski, B. B.
Powiązania:
https://bibliotekanauki.pl/articles/220649.pdf
Data publikacji:
2012
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
optical coherence tomography
corrosion
anti-corrosion coatings inspection
Opis:
Optical Coherence Tomography (OCT) is one of the most rapidly advancing techniques. This method is capable of non-contact and non-destructive investigation of the inner structure of a broad range of materials. Compared with other methods which belong to the NDE/NDT group (Non-Destructive Evaluation/Non-Destructive Testing methods), OCT is capable of a broad range of scattering material structure visualization. Such a non-invasive and versatile method is very demanded by the industry. The authors applied the OCT method to examine the corrosion process in metal samples coated by polymer films. The main aim of the research was the evaluation of the anti-corrosion protective coatings using the OCT method. The tested samples were exposed to a harsh environment. The OCT measurements have been taken at different stages of the samples degradation. The research and tests results have been presented, as well as a brief discussion has been carried out.
Źródło:
Metrology and Measurement Systems; 2012, 19, 2; 365-372
0860-8229
Pojawia się w:
Metrology and Measurement Systems
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Examination of Sol-Gel Derived Hydroxyapatite Enhanced with Silver Nanoparticles using OCT and Raman Spectroscopy
Autorzy:
Głowacki, M. J.
Gnyba, M.
Strąkowska, P.
Gardas, M.
Kraszewski, M.
Trojanowski, M.
Strąkowski, M. R.
Powiązania:
https://bibliotekanauki.pl/articles/221475.pdf
Data publikacji:
2017
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
hydroxyapatite
sol-gel
nanoparticles
Raman spectroscopy
optical coherence tomography (OCT)
Opis:
Hydroxyapatite (HAp) has been attracting widespread interest in medical applications. In a form of coating, it enables to create a durable bond between an implant and surrounding bone tissues. With addition of silver nanoparticles HAp should also provide antibacterial activity. The aim of this research was to evaluate the composition of hydroxyapatite with silver nanoparticles in a non-destructive and non-contact way. For control measurements of HAp molecular composition and solvent evaporation efficiency the Raman spectroscopy has been chosen. In order to evaluate dispersion and concentration of the silver nanoparticles inside the hydroxyapatite matrix, the optical coherence tomography (OCT) has been used. Five samples were developed and examined ‒ a reference sample of pure HAp sol and four samples of HAp colloids with different silver nanoparticle solution volume ratios. The Raman spectra for each solution have been obtained and analyzed. Furthermore, a transverse-sectional visualization of every sample has been created and examined by means of OCT.
Źródło:
Metrology and Measurement Systems; 2017, 24, 1; 153-160
0860-8229
Pojawia się w:
Metrology and Measurement Systems
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Improving Segmentation of 3D Retina Layers Based on Graph Theory Approach for Low Quality OCT Images
Autorzy:
Stankiewicz, A.
Marciniak, T.
Dąbrowski, A.
Stopa, M.
Rakowicz, P.
Marciniak, E.
Powiązania:
https://bibliotekanauki.pl/articles/221548.pdf
Data publikacji:
2016
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
Optical Coherence Tomography (OCT)
segmentation of retinal layers
image segmentation
graph theory
Opis:
This paper presents signal processing aspects for automatic segmentation of retinal layers of the human eye. The paper draws attention to the problems that occur during the computer image processing of images obtained with the use of the Spectral Domain Optical Coherence Tomography (SD OCT). Accuracy of the retinal layer segmentation for a set of typical 3D scans with a rather low quality was shown. Some possible ways to improve quality of the final results are pointed out. The experimental studies were performed using the so-called B-scans obtained with the OCT Copernicus HR device.
Źródło:
Metrology and Measurement Systems; 2016, 23, 2; 269-280
0860-8229
Pojawia się w:
Metrology and Measurement Systems
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-5 z 5

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies