Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "cantilever" wg kryterium: Temat


Wyświetlanie 1-2 z 2
Tytuł:
Experimental Observation Of Nonlinear Vibrations Using A Closed-Loop Vibration System
Autorzy:
de Barros, E.
d’Andrade Souto, C.
Mathias, M. H.
Powiązania:
https://bibliotekanauki.pl/articles/220744.pdf
Data publikacji:
2015
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
nonlinear vibrations
closed-loop vibration system
nonlinear structural dynamics
cantilever beam
Opis:
This paper presents experimental observation of nonlinear vibrations in the response of a flexible cantilever beam to transverse harmonic base excitations around its flexural mode frequencies. In the experimental setup, instead of manual control of the signal excitation frequency and amplitude, a closed-loop vibration system is used to keep the excitation amplitude constant during the frequency sweep and to increase confidence in the experimental results. The experimental results show the presence of the third mode in the response when varying the excitation frequency around the fourth mode. The frequency-response curves, response spectrum and Poincaré plots were used for characterization of nonlinear dynamic behaviour of the beam.
Źródło:
Metrology and Measurement Systems; 2015, 22, 4; 559-564
0860-8229
Pojawia się w:
Metrology and Measurement Systems
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Metrology and control of electromagnetically actuated cantilevers using optical beam deflection method
Autorzy:
Kopiec, Daniel
Majstrzyk, Wojciech
Pruchnik, Bartosz
Gacka, Ewelina
Badura, Dominik
Sierakowski, Andrzej
Janus, Paweł
Gotszalk, Teodor
Powiązania:
https://bibliotekanauki.pl/articles/2052166.pdf
Data publikacji:
2021
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
optical beam deflection
thermomechanical noise
low frequency noise
electromagnetically actuated cantilever
Lorentz force
Opis:
In this paper, we present metrology and control methods and techniques for electromagnetically actuated microcantilevers. The electromagnetically actuated cantilevers belong to the micro electro mechanical systems (MEMS), which can be used in high resolution force and mass change investigations. In the described experiments, silicon cantilevers with an integrated Lorentz current loop were investigated. The electromagnetically actuated cantilevers were characterized using a modified optical beam deflection (OBD) system, whose architecture was optimized in order to increase its resolution. The sensitivity of the OBD system was calibrated using a reference cantilever, whose spring constant was determined through thermomechanical noise analysis registered interferometrically. The optimized and calibrated OBD system was used to observe the resonance and bidirectional static deflection of the electromagnetically deflected cantilevers. After theoretical analysis and further experiments, it was possible to obtain setup sensitivity equal to 5.28 mV/nm.
Źródło:
Metrology and Measurement Systems; 2021, 28, 4; 627-642
0860-8229
Pojawia się w:
Metrology and Measurement Systems
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-2 z 2

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies