Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "Zhao, J. J." wg kryterium: Autor


Wyświetlanie 1-4 z 4
Tytuł:
Analysis of the factors affecting the realization of lambda transition temperature of 4He
Autorzy:
Yin, L.
Lin, P.
Zhao, J. J.
Qi, X.
Powiązania:
https://bibliotekanauki.pl/articles/221031.pdf
Data publikacji:
2011
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
4He
lambda transition temperature
sealed-cell
realization
Opis:
Owing to the dramatic change in the thermal conductivity of 4He when its temperature crosses the transition of superfluid (HeI) and normalfluid (HeII), a sealed-cell with a capillary is used to realize the lambda transition temperature, Tλ. A small heat flow is controlled through the capillary of the sealed-cell so as to realize the coexistence of HeI and HeII and maintain the stay of HeI/HeII interface in the capillary. A stable and flat lambda transition temperature "plateau" is obtained. Because there is a depression effect of Tλ caused by the heat flow through the capillary, a series of heat flows and several temperature plateaus are made and an extrapolation is applied to determine Tλ with zero heat flow. A rhodium-iron resistance thermometer with series number A34 (RIRT A34) has been used in 24 Tλ -realization experiments to derive Tλ with a standard deviation of 0.022mK, which proves the stability and reproducibility of Tλ.
Źródło:
Metrology and Measurement Systems; 2011, 18, 1; 13-23
0860-8229
Pojawia się w:
Metrology and Measurement Systems
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
A 128-channel high precision time measurement module
Autorzy:
Kang, L.
Zhao, L.
Zhou, J
Liu, S.
An, Q.
Powiązania:
https://bibliotekanauki.pl/articles/221564.pdf
Data publikacji:
2013
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
high precision
time measurement
PXI
data transfer
commissioning tests
Opis:
In the external target experiment for heavy ion collisions in the HIRFL-CSR, Multi-Wire Drift Chambers are used to measure the drift time of charged particles to obtain the track information. This 128-channel high precision time measurement module is designed to perform the time digitization. The data transfer is based on a PXI interface to guarantee a high data rate. Test results show that a 100 ps resolution with a data transfer rate up to 40 MBps has been achieved; this module has also been proven to function well with the detector through a commissioning test.
Źródło:
Metrology and Measurement Systems; 2013, 20, 2; 275-286
0860-8229
Pojawia się w:
Metrology and Measurement Systems
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Automatic Laser Interferometer And Vision Measurement System For Stripe Rod Calibration
Autorzy:
Zhao, M.
Huang, Q.-H.
Zhu, L.-J.
Qiu, Z.-M.
Powiązania:
https://bibliotekanauki.pl/articles/221047.pdf
Data publikacji:
2015
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
stripe edge
automatic control
laser interferometer
vision measurement
Opis:
In order to calibrate the stripe precision of a leveling rod, an automatic laser interferometer and a vision measurement system were designed by Xi’an University of Technology in China. The rod was driven by a closed-loop control and the data were collected at the stop state to ensure precision. The laser interferometer provided not only the long distance data but also a position feedback signal in the automatic control loop. CCD camera and a vision measurement method were used to inspect the stripe edge position and defect. Apixel-equivalent self-calibration method was designed to improve precision. ROI (regions of interest) method and an outline tracing method were designed to quickly extract multiple stripe edges. A combination of the image data with the interferometer data reduces control difficulty and ensures the measurement accuracy. The vision measurement method reached sub-pixel precision and the defective edges were reported. The system can automatically calibrate a stripe leveling rod with a high degree of efficiency and precision.
Źródło:
Metrology and Measurement Systems; 2015, 22, 4; 491-502
0860-8229
Pojawia się w:
Metrology and Measurement Systems
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
An improved resonant thermal converter based on micro-bridge resonator
Autorzy:
Dong, L.
Han, J.
Zhang, P.
Zhao, Z.
Cheng, B.
Han, D.
Powiązania:
https://bibliotekanauki.pl/articles/220878.pdf
Data publikacji:
2018
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
thermoelectric transfer difference
micro-bridge resonator
thermal converter
bifilar heater
Opis:
This paper presents the design, fabrication and testing of an improved thin-film thermal converter based on an electro-thermally excited and piezo-resistively detected micro-bridge resonator. The resonant thermal converter comprises a bifilar heater and an opposing micro-bridge resonator. When the micro-bridge resonator absorbs the radiant heat from the heater, its axial strain changes, then its resonant frequency follows. Therefore the alternating voltage or current can be transferred to the equivalent DC quantity. A non-contact temperature sensing mechanism eliminates heat loss from thermopiles and reduces coupling capacitance between the temperature sensor and the heater compared with traditional thin-film thermal converters based on thermopiles. In addition, the quasi-digital output of the resonant thin-film thermal converter eliminates such problems as intensity fluctuations associated with analogue signals output by traditional thin-film thermal converters. Using the fast-reversed DC (FRDC) method, the thermoelectric transfer difference, which determines the frequency-independent part of the ac-dc transfer difference, is evaluated to be as low as 1.1 · 10-6. It indicates that the non-contact temperature sensing mechanism is a feasible method to develop a high-performance thermal converter.
Źródło:
Metrology and Measurement Systems; 2018, 25, 4; 715-725
0860-8229
Pojawia się w:
Metrology and Measurement Systems
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-4 z 4

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies