Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "Li, J. H." wg kryterium: Autor


Wyświetlanie 1-4 z 4
Tytuł:
A velocity measurement method based on scaling parameter estimation of chaotic system
Autorzy:
Liu, L.
Hu, J.
He, Z.
Han, C.
Li, H.
Li, J.
Powiązania:
https://bibliotekanauki.pl/articles/220466.pdf
Data publikacji:
2011
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
signal processing
parameter estimation
chaos
synchronization
Opis:
In this paper, we propose a new method of measuring the target velocity by estimating the scaling parameter of a chaos-generating system. First, we derive the relation between the target velocity and the scaling parameter of the chaos-generating system. Then a new method for scaling parameter estimation of the chaotic system is proposed by exploiting the chaotic synchronization property. Finally, numerical simulations show the effectiveness of the proposed method in target velocity measurement.
Źródło:
Metrology and Measurement Systems; 2011, 18, 2; 275-281
0860-8229
Pojawia się w:
Metrology and Measurement Systems
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
In Situ Measurements of Atmospheric CO And Its Correlation With Nox And O3 at a Rural Mountain Site
Autorzy:
Li, J.
Reiffs, A.
Parchatka, U.
Fischer, H.
Powiązania:
https://bibliotekanauki.pl/articles/221507.pdf
Data publikacji:
2015
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
trace gas measurements
atmospheric CO
QCL sensor
sources relation
sources identification
Opis:
Ambient concentrations of CO, as well as NOx and O3, were measured as a part of the PARADE campaign conducted at the Taunus Observatory on the summit of the Kleiner Feldberg between the 8th of August and 9th of September 2011. These measurements were made in an effort to provide insight into the characteristics of the effects of both biogenic and anthropogenic emissions on atmospheric chemistry in the rural south-western German environment. The overall average CO concentration was found to be 100.3±18.1 ppbv (within the range of 71 to 180 ppbv), determined from 10-min averages during the summer season. The background CO concentration was estimated to be ~90 ppbv. CO and NOx showed bimodal diurnal variations with peaks in the late morning (10:00-12:00 UTC) and in the late afternoon (17:00-20:00 UTC). Strong correlations between CO and NOx indicated that vehicular emission was the major contributor to the notable CO plumes observed at the sampling site. Both local meteorology and backward trajectory analyses suggest that CO plumes were associated with anthropogenically polluted air masses transferred by an advection to the site from densely populated city sites. Furthermore, a good linear correlation of R2 = 0.54 between CO and O3 (∆O3/∆CO=0.560±0.016 ppbv/ppbv) was observed, in good agreement with previous observations.
Źródło:
Metrology and Measurement Systems; 2015, 22, 1; 25-38
0860-8229
Pojawia się w:
Metrology and Measurement Systems
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
New compensation scheme of magneto-optical current sensor for temperature stability improvement
Autorzy:
Chen, J.
Li, H.
Zhang, M.
Zhang, Y.
Powiązania:
https://bibliotekanauki.pl/articles/221874.pdf
Data publikacji:
2012
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
magneto-optical current sensor
normalization
Verdet constant
birefringence
Opis:
A novel magneto-optical current sensor (MOCS) with two sensing arms is proposed to improve the temperature stability. One of the arms, with a highly stable permanent magnet attached and orthogonal to the other one, is designed to provide a reference that follows the temperature characteristics of the sensing material. By a normalization operation between two arms, the temperature drift is compensated adaptively and a sensing output proportional to the measured current can be reached. A dual-input and dual-output structure is specially designed for the reference sensing arm to demodulate the DC Faraday rotation angle. This scheme compensates simultaneously two main temperature influence factors, the Verdet constant and linear birefringence. Validation tests were carried out and are discussed.
Źródło:
Metrology and Measurement Systems; 2012, 19, 3; 611-616
0860-8229
Pojawia się w:
Metrology and Measurement Systems
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Measurement of Surface Profile and Surface Roughness of Fibre-Optic Interconnect by Fast Fourier Transform
Autorzy:
Lin, C. S.
Yang, S. W.
Lin, H. L.
Li, J. W.
Powiązania:
https://bibliotekanauki.pl/articles/221117.pdf
Data publikacji:
2017
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
surface profile
surface roughness
fibre end-face
fast Fourier transform
Opis:
This study proposes a surface profile and roughness measurement system for a fibre-optic interconnect based on optical interferometry. On the principle of Fizeau interferometer, an interference fringe is formed on the fibre end-face of the fibre-optic interconnect, and the fringe pattern is analysed using the Fast Fourier transform method to reconstruct the surface profile. However, as the obtained surface profile contains some amount of tilt, a rule for estimating this tilt value is developed in this paper. The actual fibre end-face surface profile is obtained by subtracting the estimated tilt amount from the surface profile, as calculated by the Fast Fourier transform method, and the corresponding surface roughness can be determined. The proposed system is characterized by non-contact measurement, and the sample is not coated with a reflector during measurement. According to the experimental results, the difference between the roughness measurement result of an Atomic Force Microscope (AFM) and the measurement result of this system is less than 3 nm.
Źródło:
Metrology and Measurement Systems; 2017, 24, 2; 381-390
0860-8229
Pojawia się w:
Metrology and Measurement Systems
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-4 z 4

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies